Comparison of the blink-reflex obtaines using needleelectrodes and surfaceelectrodesPublication History
Publication Date:
18 March 2008 (online)
Summary
The electrically released Blink-Reflex was registered on four channels simultaneously using needle- and surface - electrodes. 17 healthy volunteers were examined.
The latencies of the R1-, R2-and R2'- components are comparable using both recording technics. The amplitudes of the reflex coponents however show great variation using as well needle- and surface electrodes. The amplitudes didn't turn out to be more stable using surface electrodes. For the clinical use this result implies that both recording technics produce comparable latenzies and therefore can be used alternatively according to the special necessities of examination.
Zusammenfassung
Der elektrisch ausgelöste Blinkreflex wurde bei 17 gesunden Versuchspersonen auf vier Kanälen simultan mit Oberflächen- und Nadelektroden untersucht. Die Latenzen der Komponenten R1, R2 und R2' sind bei beiden Ableitungsarten vergleichbar. Die Amplitudenwerte streuen sowohl bei der Nadel- als auch bei der Oberflächenelektrodenab-leitung sehr stark. Die Amplituden sind bei Oberflächenableitung nicht stabiler als bei Nadelelektrodenableitung. Für die Praxis bedeutet dies, daß die Latenzzeiten, die mit Nadel- und Oberflächenableitung bestimmt werden, vergleichbar sind. Hierdurch ergibt sich die Möglichkeit, je nach Untersuchungssituation alternativ mit Nadel- oder Oberflächenelektroden abzuleiten.
Key Words:
Orbicularis oculi reflex - Blink reflex - Recording technic