Eur J Pediatr Surg 1981; 32(1): 90-94
DOI: 10.1055/s-2008-1063241
Falldarstellungen

© Georg Thieme Verlag KG Stuttgart · New York

Umbilical Core-out Operation for a Completely Patent Vitelline Duct

Sbuji  Asano , Hideki  Kitatani , Fujitsugu  Matsubara , Shou-Yuan  Lin
  • From the Department of Pediatric Surgery, Ishikawa Prefectural Central Hospital, and the Central Clinical Laboratory, Kanazawa University Hospital, Kanazawa, Japan
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
25. März 2008 (online)

Abstract

An umbilical core-out operation for a completely patent vitelline duct in a premature baby with successful preoperative manual reduction of the prolapsed ileal loops is described. In certain cases with this rare anomaly this procedure can be applied. The procedure is easy, timesaving, bloodless and necessitates no laparotomy incision.

Zusammenfassung

Ein transumbilikales Vorgehen bei einem vollständig offenen Ductus omphaloentericus wird beschrieben Bei dem Frühgeborenen wurden zuvor die durch den Ductus omphaloentericus prolabierten Dünndarmschlingen reponiert Diese Methode wird für bestimmte Fälle dieser seltenen Anomalie empfohlen. Das Vorgehen ist leicht, zeitsparend blutarm und erfordert keine Laparotomien.