V / Q-Szintigrafie zur Diagnostik der Lungenembolie – II. SPECT und SPECT-CT in der nuklearmedizinischen Lungendiagnostik
Diagnosis of Lung Embolism by V / Q Scintigraphy – SPECT and SPECT-CT for Pulmonary Diagnostic in Nuclear MedicinePublication History
Publication Date:
02 December 2008 (online)
Zusammenfassung
Die Ventilations- und Perfusions-SPECT der Lunge stellt eine sinnvolle Weiterentwicklung dieser Untersuchung dar. Nach einem kurzen technischen Überblick werden Einsatzmöglichkeiten und Ergebnisse den klinischen Fragestellungen Lungenembolie, Voraussage der postoperativen Lungenfunktion sowie pulmonale Radioaerosoldeposition und Clearance diskutiert.
Abstract
Imaging of the pulmonary ventilation and perfusion by using SPECT proved to be a useful development of this examination. At first this article gives a brief overview of the technical aspects followed by a discussion of clinical questions regarding pulmonary embolism, preoperative assessment of postoperative lung function as well as radioaerosol deposition and clearance.
Schlüsselwörter
Lungenembolie - V / Q-Szintigrafie - Lungenszintigrafie - SPECT - SPECT-CT
Key words
pulmonary embolism - V / Q scintigraphy - lung scintigraphy - SPECT - SPECT-CT
Literatur
- 1 Ashburn W L, Belezzuoli E V, Dillon W A et al. Technetium-99m labeled micro aerosol “Pertechnegas”. A new agent for ventilation imaging in suspected pulmonary emboli. Clin Nucl Med. 1993; 18 1045-1052
- 2 Bailey D L, Schembri G P, Harris B E et al. Generation of planar images from lung ventilation / perfusion SPECT. Ann Nucl Med. 2008; 22 437-445
- 3 Bajc M, Bitzen U, Olsson B et al. Lung ventilation / perfusion SPECT in the artificially embolized pig. J Nucl Med. 2002; 43 640-647
- 4 Bajc M, Olsson C G, Olsson B et al. Diagnostic evaluation of planar and tomographic ventilation / perfusion lung images in patients with suspected pulmonary emboli. Clin Physiol Funct Imaging. 2004; 24 249-256
- 5 Bajc M, Olsson B, Palmer J et al. Ventilation / perfusion SPECT for diagnostics of pulmonary embolism in clinical practice. J Intern Med. 2008; 264 379-387
- 6 Biersack H J, Altland H, Knopp R et al. Single photon emission computed tomography of the lung: preliminary results. Eur J Nucl Med. 1982; 7 166-170
- 7 Collart J P, Roelants V, Vanpee D et al. Is a lung perfusion scan obtained by using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism?. Nucl Med Commun. 2002; 23 1107-1113
- 8 Corbus H F, Seitz J P, Larson R K et al. Diagnostic usefulness of lung SPET in pulmonary thromboembolism: an outcome study. Nucl Med Commun. 1997; 18 897-906
- 9 Dworkin H J, Hamilton C, Simeck C M et al. Lung scanning with colloidal risa. J Nucl Med. 1964; 5 48-56
- 10 Eberl S, Chan H K, Daviskas E et al. Aerosol deposition and clearance measurement: a novel technique using dynamic SPECT. Eur J Nucl Med. 2001; 28 1365-1372
- 11 Eberl S, Chan H K, Daviskas E. SPECT Imaging for radioaerosol deposition and clearance studies. J Aerosol Med. 2006; 19 8-20
- 12 Harris B, Bailey D L, Roach P J et al. A clinical comparison between traditional planar V / Q images and planar images generated from SPECT V / Q scintigraphy. Nucl Med Commun. 2008; 29 323-330
- 13 Haynie T P, Calhoon J H, Nasjleti C E et al. Visualization of pulmonary artery occlusion by photoscanning. JAMA. 1963; 185 306-308
- 14 Hirose Y, Imaeda T, Doi H et al. Lung perfusion SPECT in predicting postoperative pulmonary function in lung cancer. Ann Nucl Med. 1993; 7 123-126
- 15 The PIOPED Investigators . Value of the ventilation / perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). JAMA. 1990; 263 2753-2759
- 16 Jogi J, Palmer J, Jonson B et al. Heart failure diagnostics based on ventilation / perfusion single photon emission computed tomography pattern and quantitative perfusion gradients. Nucl Med Commun. 2008; 29 666-673
- 17 Leblanc M, Leveillee F, Turcotte E. Prospective evaluation of the negative predictive value of V / Q SPECT using 99mTc-Technegas. Nucl Med Commun. 2007; 28 667-672
- 18 Links J M, Frank T L, Becker L C. Effect of differential tracer washout during SPECT acquisition. J Nucl Med. 1991; 32 2253-2257
- 19 Machida K, Nishikawa J, Ishimaru J. Better delineation of pulmonary perfusion defect by the single photon emission computed tomography (case report). Radioisotopes. 1980; 29 498-499
- 20 Magnussen J S, Chicco P, Palmer A W et al. Single-photon emission tomography of a computerised model of pulmonary embolism. Eur J Nucl Med. 1999; 26 1430-1438
- 21 Nakajima K, Shuke N, Taki J et al. A simulation of dynamic SPECT using radiopharmaceuticals with rapid clearance. J Nucl Med. 1992; 33 1200-1206
- 22 Ohno Y, Koyama H, Nogami M et al. Postoperative lung function in lung cancer patients: comparative analysis of predictive capability of MRI, CT, and SPECT. AJR Am J Roentgenol. 2007; 189 400-408
- 23 Ohno Y, Koyama H, Takenaka D et al. Coregistered ventilation and perfusion SPECT using krypton-81m and Tc-99m-labeled macroaggregated albumin with multislice CT utility for prediction of postoperative lung function in non-small cell lung cancer patients. Acad Radiol. 2007; 14 830-838
- 24 Osborne D R, Jaszczak R J, Greer K et al. Detection of pulmonary emboli in dogs: comparison of single photon emission computed tomography, gamma camera imaging, and angiography. Radiology. 1983; 146 493-497
- 25 Palmer J, Bitzen U, Jonson B et al. Comprehensive ventilation / perfusion SPECT. J Nucl Med. 2001; 42 1288-1294
- 26 Phipps P R, Gonda I, Bailey D L et al. Comparisons of planar and tomographic gamma scintigraphy to measure the penetration index of inhaled aerosols. Am Rev Respir Dis. 1989; 139 1516-1523
- 27 Piai D B, Quagliatto Jr R, Toro I et al. The use of SPECT in preoperative assessment of patients with lung cancer. Eur Respir J. 2004; 24 258-262
- 28 Reinartz P, Kaiser H J, Wildberger J E et al. SPECT imaging in the diagnosis of pulmonary embolism: automated detection of match and mismatch defects by means of image-processing techniques. J Nucl Med. 2006; 47 968-973
-
29 Reinartz P, Sabri O. Lunge. In: Kuwert T, Grünwald F, Haberkorn U, Krause T, eds. Nuklearmedizin. Stuttgart, New York: Thieme; 2008: 258–271
- 30 Reinartz P, Schirp U, Zimny M et al. Optimizing ventilation-perfusion lung scintigraphy: parting with planar imaging. Nuklearmedizin. 2001; 40 38-43
- 31 Reinartz P, Wildberger J E, Schaefer W et al. Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V / Q lung scintigraphy in SPECT technique and multislice spiral CT. J Nucl Med. 2004; 45 1501-1508
- 32 Robinson P J. Ventilation-perfusion lung scanning and spiral computed tomography of the lungs: competing or complementary modalities?. Eur J Nucl Med. 1996; 23 1547-1553
- 33 Sanchez-Crespo A, Rohdin M, Carlsson C et al. A technique for lung ventilation-perfusion SPECT in neonates and infants. Nucl Med Commun. 2008; 29 173-177
- 34 Sandrock D, Munz D L. Lungenperfusions- und Ventilationsszintigraphie in der prä- und postoperativen Diagnostik. Der Nuklearmediziner. 1998; 21 55-58
-
35 Schümichen C, Krause T, Rainartz P. Leitlinien für die Lungenszintigraphie Version 2. In: http://www.nuklearmedizin.de/publikationen/leitlinien/lunge_szin.php
, ed., 2007
- 36 Schwickert H C, Kauczor H U, Piepenburg R et al. [CT compared with SPECT in chronic recurrent pulmonary embolism: hyperdensities as signs of pulmonary artery hyperperfusion?]. Rofo. 1995; 162 199-203
- 37 Stavngaard T, Mortensen J. Assessment of ventilation inhomogenity with Krypton SPECT and planar imaging. Clin Physiol Funct Imaging. 2005; 25 106-112
- 38 Stein P D. Diagnosis and management of pulmonary embolism. Curr Opin Cardiol. 1996; 11 543-549
- 39 Sudoh M, Ueda K, Kaneda Y et al. Breath-hold single-photon emission tomography and computed tomography for predicting residual pulmonary function in patients with lung cancer. J Thorac Cardiovasc Surg. 2006; 131 994-1001
- 40 Suga K, Kawakami Y, Iwanaga H et al. Comprehensive assessment of lung CT attenuation alteration at perfusion defects of acute pulmonary thromboembolism with breath-hold SPECT-CT fusion images. J Comput Assist Tomogr. 2006; 30 83-91
- 41 Suga K, Kawakami Y, Iwanaga H et al. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images. Ann Nucl Med. 2008; 22 339-347
- 42 Suga K, Kawakami Y, Iwanaga H et al. Automated breath-hold perfusion SPECT / CT fusion images of the lungs. AJR Am J Roentgenol. 2007; 189 455-463
- 43 Suga K, Kawakami Y, Zaki M et al. Pulmonary perfusion assessment with respiratory gated 99mTc macroaggregated albumin SPECT: preliminary results. Nucl Med Commun. 2004; 25 183-193
- 44 Suga K, Kawakami Y, Zaki M et al. Clinical utility of co-registered respiratory-gated (99m)Tc-Technegas / MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer. Eur J Nucl Med Mol Imaging. 2004; 31 1280-1290
- 45 Suga K, Nishigauchi K, Kume N et al. Ventilation abnormalities in obstructive airways disorder: detection with pulmonary dynamic densitometry by means of spiral CT versus dynamic Xe-133 SPECT. Radiology. 1997; 202 855-862
- 46 Suga K, Nishigauchi K, Matsunaga N et al. Three-dimensional surface displays of perfusion SPET in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery. Nucl Med Commun. 1997; 18 719-727
- 47 Suga K, Yasuhiko K, Iwanaga H et al. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: Assessment with breath-hold SPECT-CT pulmonary angiography fusion images. Eur J Radiol. 2007; 1 1
Prof. Dr. T. Krause
Universitätsklinik für Nuklearmedizin · Inselspital
CH 3010 Bern
Phone: +41 / 31 / 6 32 26 10
Fax: +41 / 31 / 6 32 31 37
Email: Thomas.Krause@insel.ch