Thromb Haemost 2005; 94(06): 1156-1163
DOI: 10.1160/TH05-05-0347
Blood Coagulation, Fibrinolysis and Cellular Haemostasis
Schattauer GmbH

Pharmacodynamic markers in the early clinical assessment of otamixaban, a direct factor Xa inhibitor

Anne Paccaly
1   Sanofi-aventis, Science and Medical Affairs Bridgewater New Jersey, USA
,
Marie-Laure Ozoux
2   Vitry-Alfortville, France
,
Valeria Chu
1   Sanofi-aventis, Science and Medical Affairs Bridgewater New Jersey, USA
,
Kelly Simcox
1   Sanofi-aventis, Science and Medical Affairs Bridgewater New Jersey, USA
,
Vanessa Marks
3   Croix de Berny, France
,
Geneviève Freyburger
4   4 Laboratoire d’Hématologie Hôpital Pellegrin, Bordeaux, France
,
Michel Sibille
5   5 Association de Recherche Thérapeutique, Centre Hospitalier Lyon-Sud, France
,
Umesh Shukla*
1   Sanofi-aventis, Science and Medical Affairs Bridgewater New Jersey, USA
› Author Affiliations

Financial support: This study was supported by Sanofi-aventis.
Further Information

Publication History

Received 19 May 2005

Accepted after resubmission 07 October 2005

Publication Date:
07 December 2017 (online)

Preview

Summary

This manuscript reports the assessment of pharmacodynamic (PD) markers of anti-coagulation in the first-in-man study with the novel direct Factor Xa (FXa) inhibitor, otamixaban, with a brief description of safety and pharmacokinetic (PK) findings. The study comprised ten consecutive parallel groups of healthy male subjects (6 active, 2 placebo per group). Eight groups received escalating intravenous doses of otamixaban as 6-hour infusions (1.7 to 183 μg/kg/h) and two groups received a bolus dose (30 or 120 μg/kg) with a 6-hour infusion (60 or 140 μg/ kg/h, respectively). PD markers included anti-FXa activity and clotting time measurements, i.e. activated Thromboplastin Time (aPTT), ProthrombinTime (PT), Heptest® ClottingTime (HCT), and Russell’s Viper Venom-induced clotting Time (RVVT). In addition, Endogenous Thrombin Potential (ETP) was assessed in the bolus-plus-infusion dose groups. Otamixaban was well tolerated. Otamixaban plasma concentrations increased with escalating dose, were maximal at the end-of-infusion (Ceoi), and decreased rapidly as the infusion was stopped. Anti-FXa activity coincided with otamixaban plasma concentrations and clotting time measurements followed the same pattern. Maximal changes from baseline at Ceoi were 1.9 ± 0.2 for aPTT, 2.0 ± 0.2 for PT, 5.1 ± 0.6 for HCT, and 4.5 ± 1.2 for RVVT. Otamixaban inhibited thrombin generation (24% decrease in ETP) and a delay in thrombin generation was noticed in vitro at high concentrations.

* Current address: Clinical Drug Evaluation, Johnson & Johnson Pharmaceutical Research & Development, Raritan, New Jersey, USA