Subscribe to RSS
Please copy the URL and add it into your RSS Feed Reader.
https://www.thieme-connect.de/rss/thieme/en/10.1055-s-00035024.xml
Thromb Haemost 2008; 100(06): 1193-1195
DOI: 10.1160/TH08-04-0267
DOI: 10.1160/TH08-04-0267
Case Report
Retrievable filter as an unusual cause of abdominal and lower back pain: A report of an exceptional case
Further Information
Publication History
Received:
29 April 2008
Accepted after minor revision:
05 September 2008
Publication Date:
23 November 2017 (online)
-
References
- 1 Buller HR, Agnelli G, Hull RD. et al. Antithrombotic therapy for venous thromboembolic disease: the Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy. Chest 2004; 126: 401S-428S.
- 2 Carman TL, Alahmad A. Update on vena cava filters. Curr Treat Options Cardiovasc Med 2008; 10: 101-111.
- 3 Caronno R, Piffaretti G, Tozzi M. et al. Mid-term experience with the ALN retrievable inferior vena cava filter. Eur J Vasc Endovasc Surg 2006; 32: 596-599.
- 4 Mismetti P, Rivron-Guillot K, Quenet S. et al. A prospective long-term study of 220 patients with a retrievable vena cava filter for secondary prevention of venous thromboembolism. Chest 2007; 131: 223-229.
- 5 Ku GH, Billett HH. Long lives, short indications. The case for removable inferior cava filters. Thromb Haemost 2005; 93: 17-22.
- 6 Kim HS, Young MJ, Narayan AK. et al. A comparison of clinical outcomes with retrievable and permanent inferior vena cava filters. J Vasc Interv Radiol 2008; 19: 393-399.
- 7 Imberti D, Bianchi M, Farina A. et al. Clinical experience with retrievable vena cava filters: results of a prospective observational multicenter study. J Thromb Haemost 2005; 03: 1370-1375.
- 8 Berczi V, Bottomley JR, Thomas SM. et al. Longterm retrievability of IVC filters: Should we abandon permanent devices?. Cardiovasc Intervent Radiol 2007; 30: 820-827.
- 9 Crowther MA. Inferior vena cava filters in the management of venous thromboembolism. Am J Med 2007; 120: S13-17.
- 10 Seddighzadeh A, Zurawska U, Shetty R. et al. Venous thromboembolism in patients undergoing surgery: low rates of prophylaxis and high rates of filter insertion. Thromb Haemost 2007; 98: 1220-1225.
- 11 Jaff MR, Goldhaber SZ, Tapson VF. High utilization rate of vena cava filters in deep vein thrombosis. Thromb Haemost 2005; 93: 1117-1119.
- 12 Kim D, Porter DH, Seigal JB. et al. Perforation of the interior vena cava with aortic and vertebral penetration by a suprarenal Greenfield filter. Radiology 1989; 172: 721-723.