CC BY 4.0 · Aorta (Stamford) 2015; 03(01): 16-24
DOI: 10.12945/j.aorta.2015.14-050
State-of-the-Art Review
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Application of the Bolton Relay Device for Thoracic Endografting In or Near the Aortic Arch

Vincent Riambau
1   Vascular Surgery Division, Thorax Institute, Hospital Clinic of Barcelona, Barcelona, Spain
› Institutsangaben
Weitere Informationen

Publikationsverlauf

07. August 2014

05. Dezember 2015

Publikationsdatum:
24. September 2018 (online)

Abstract

Endovascular correction of aortic arch pathology remains a challenge, with a variety of techniques proposed over the years to minimize complications and enhance the probability of a successful result. A variety of approaches have been developed in order to deal with the aortic arch pathology and its idiosyncrasies. We review potential interventional techniques for the repair of aortic arch pathologies, beginning with conventional aortic arch surgery, followed by hybrid treatments and those along the endovascular spectrum (parallel and fenestrated endografts, scalloped endografts, and ascending and new branched endografts). We finish with an overview of all the Bolton Medical (Barcelona, Spain and Sunrise, FL, USA) thoracic platforms. Endovascular techniques show acceptable results in selected cases. Both proximal Bolton Relay configurations (with and without a bare stent) offer conformability and accuracy on deployment with very low rates of stroke. Fenestrated and scalloped designs are also useful for selected cases. Ascending and branched Bolton devices are very promising platforms for a serious, full endovascular approach to the aorta.

 
  • References

  • 1 Booher AM, Eagle KA. Diagnosis and management issues in thoracic aortic aneurysm. Am Heart J 2011; 162: 38-46 . DOI: 10.1016/j.ahj.2011.04.010
  • 2 WISQARS Leading Causes of Death Reports, 1999 - 2007. National Center for Injury Prevention and Control. http://webappa.cdc.gov/sasweb/ncipc/leadcaus10.html . Updated June, 2010
  • 3 Dake M, Kato N, Mitchell S, Semba C, Razavi M, Shimono T. , et al. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med 1999; 340: 1546-1552 . DOI: 10.1056/NEJM199905203402004
  • 4 Kouchoukos NT, Dougenis D. Surgery of the thoracic aorta. N Engl J Med 1997; 336: 1876-89 . DOI: 10.1056/NEJM199706263362606
  • 5 LeMaire S, Price M, Parenti J, Johnson M, Lay A, Preventza O. , et al. Early outcomes after aortic arch replacement by using the Y-graft technique. Ann Thorac Surg 2011; 91: 700-707 . DOI: 10.1016/j.athoracsur.2010.11.008
  • 6 Kos X, Bouchard L, Otal P, Chabbert V, Chemla P, Soula P. , et al. Stent-graft treatment of penetrating thoracic aortic ulcers. J Endovasc Ther 2002; 9: 1125-1131 . DOI: 10.1583/1545-1550-9.sp3.25
  • 7 Moon MC, Morales JP, Greenberg RK. The aortic arch and ascending aorta: are they within the endovascular realm?. Semin Vasc Surg 2007; 20: 97-107 . DOI: 10.1053/j.semvascsurg.2007.04.007
  • 8 Apostolakis E, Akinosoglou K. The methodologies of hypothermic circulatory arrest and of antegrade and retrograde cerebral perfusion for aortic arch surgery. Ann Thorac Cardiovasc Surg 2008; 14: 138-148 . PMID: 18577891
  • 9 Spielvogel D, Etz CD, Silovitz D, Lansman SL, Griepp RB. Aortic arch replacement with a trifurcated graft. Ann Thorac Surg 2007; 83: S791-S795 . DOI: 10.1016/j.athoracsur.2006.11.015
  • 10 Yoshida RA, Kolvenbach R, Yoshida WB, Wassijew S, Schwierz E, Lin F. Total endovascular debranching of the aortic arch. Eur J Vasc Endovasc Surg 2011; 42: 627-630 . DOI: 10.1016/j.ejvs.2011.06.054
  • 11 Moulakakis KG, Mylonas SN, Markatis F, Kotsis T, Kakisis J, Liapis CD. A systematic review and meta-analysis of hybrid aortic arch replacement. Ann Cardiothorac Surg 2013; 2: 247-260 . DOI: 10.3978/j.issn.2225-319X.2013.05.06
  • 12 Ferrero E, Ferri M, Viazzo A, Robaldo A, Zingarelli E, Sansone F. , et al. Is total debranching a safe procedure for extensive aortic-arch disease? A single experience of 27 cases. Eur J Cardio-Thorac Surg 2012; 41: 177-182 . DOI: 10.1016/j.ejcts.2011.05.058
  • 13 Chiesa R, Melissano G, Tshomba Y, Civilini E, Marone EM, Bertoglio L. , et al. Ten years of endovascular aortic arch repair. J Endovasc Ther 2010; 17: 1-11 . DOI: 10.1583/09-2884.1
  • 14 Gelpi G, Vanelli P, Mangini A, Danna P, Contino M, Antona C. Hybrid aortic arch repair procedure: reinforcement of the aorta for a safe and durable landing zone. Eur J Vasc Endovasc Surg 2010; 40: 709-714 . DOI: 10.1016/j.ejvs.2010.08.017
  • 15 Gottardi R, Funovics M, Eggers N, Hirner A, Dorfmeister M, Holfeld J. , et al. Supra-aortic transposition for combined vascular and endovascular repair of aortic arch pathology. Ann Thorac Surg 2008; 86: 1524-1529 . DOI: 10.1016/j.athoracsur.2008.06.075
  • 16 Piffaretti G, Mariscalco G, Lomazzi C, Rivolta N, Riva F, Tozzi M. , et al. Predictive factors for endoleaks after thoracic aortic aneurysm endograft repair. J Thorac Cardiovasc Surg 2009; 138: 880-885 . DOI: 10.1016/j.jtcvs.2009.02.024
  • 17 Hughes GC, Daneshmand MA, Balsara KR. “Hybrid” repair of aneurysms of the transverse aortic arch: midterm results. Ann Thorac Surg 2009; 88: 1882-1887 . DOI: 10.1016/j.jvs.2010.04.004
  • 18 Scali S, Goodney P, Walsh D, Travis L, Nolan B, Goodman D. , et al. National trends and regional variation of open and endovascular repair of thoracic and thoracoabdominal aneurysms in contemporary practice. J Vasc Surg 2011; 53: 1499-1505 . DOI: 10.1016/j.jvs.2011.02.014
  • 19 Goodney P, Travis L, Lucas F, Fillinger M, Goodman D, Cronenwett J. , et al. Survival after open versus endovascular thoracic aortic aneurysm repair in an observational study of the Medicare population. Circulation 2011; 124: 2661-2669 . DOI: 10.1161/circulationaha.111.033944
  • 20 Patterson B, Holt P, Nienaber C, Cambria R, Fairman R, Thompson M. Aortic pathology determines midterm outcome after endovascular repair of the thoracic aorta: report from the Medtronic Thoracic Endovascular Registry (MOTHER) database. Circulation 2013; 127: 24-32 . DOI: 10.1161/circulationaha.112.110056
  • 21 Gehringhoff B, Torsello G, Pitoulias GA, Austermann M, Donas KP. Use of chimney grafts in aortic arch pathologies involving the supra-aortic branches. J Endovasc Ther 2011; 18: 650-655 . DOI: 10.1583/11-3504.1
  • 22 Amiot S, Haulon S, Becquemin JP, Magnan PE, Lermusiaux P, Goueffic Y. , et al. Fenestrated endovascular grafting: the French multicentre experience. Eur J Vasc Endovasc Surg 2010; 39: 537-544 . DOI: 10.1016/j.ejvs.2009.12.008
  • 23 Yang J, Xiong J, Liu X, Jia X, Zhu Y, Guo W. Endovascular chimney technique of aortic arch pathologies: A systematic review. Ann Vasc Surg 2012; 26: 1014-1021 . DOI: 10.1016/j.avsg.2012.05.014
  • 24 Azuma T, Yokoi Y, Yamazaki K. The next generation of fenestrated endografts: results of a clinical trial to support an expanded indication for aortic arch aneurysm treatment. Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg 2013; 44: e156-e163 . DOI: 10.1093/ejcts/ezt241
  • 25 Inoue K, Hosokawa H, Iwase T, Sato M, Yoshida Y, Ueno K. , et al. Aortic arch reconstruction by transluminally placed endovascular branched stent graft. Circulation 1999; 100: II-316-Ii-321 . DOI: 10.1161/01.cir.100.suppl_2.ii-316
  • 26 Schneider DB, Curry TK, Reilly LM, Kang JW, Messina LM, Chuter TAM. Branched endovascular repair of aortic arch aneurysm with a modular stent-graft system. J Vasc Surg 2003; 38: 855 . DOI: 10.1016/s0741-5214(03)01024-3
  • 27 Chuter TAM, Schneider DB, Reilly LM, Lobo EP, Messina LM. Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection. J Vasc Surg 2003; 38: 859-863 . DOI: 10.1016/s0741-5214(03)01023-1
  • 28 Piffaretti G, Rivolta N, Fontana F, Carrafiello G, Mariscalco G, Castelli P. Aortic arch aneurysm repair with a new branched device. J Vasc Surg 2013; 57: 1664-1667 . DOI: 10.1016/j.jvs.2012.10.080
  • 29 Riambau V, Zipfel B, Coppi G, Czerny M, Tealdi D, Ferro C. , et al. Final operative and midterm results of the European experience in the RELAY Endovascular Registry for Thoracic Disease (RESTORE) study. J Vasc Surg 2011; 53: 565-573 . DOI: 10.1016/j.jvs.2010.09.050
  • 30 Zipfel B, Czerny M, Funovics M, Coppi G, Ferro C, Rousseau H. , et al. Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: Results from the RESTORE Patient Registry. J Endovasc Ther 2011; 18: 131-143 . DOI: 10.1583/10-3233mr.1
  • 31 Kashef E, Aldin Z, Jenkins M, Gibbs R, Bicknell C, Cheshire N. , et al. Scalloped thoracic stent-graft for treatment of aortic arch aneurysms with unfavourable landing zones. Cardiovasc Intervent Radiol 2011; 34: 845-851 . DOI: 10.1007/s00270-011-0099-9
  • 32 Yunoki J, Kuratani T, Shirakawa Y, Torikai K, Shimamura K, Kin K. , et al. Clinical experience with the RELAY NBS PLUS stent–graft for aortic arch pathology. Surgery Today 2014; 44: 2263-2268 . DOI: 10.1007/s00595-014-0851-2