Arquivos Internacionais de Otorrinolaringologia 2011; 15(02): 214-222
DOI: 10.1590/S1809-48722011000200015
Update Article
Thieme Publicações Ltda Rio de Janeiro, Brazil

Hearing Aid Fitting Protocols for Adults and Elderly Individuals

Protocolo de Seleção e Adaptação de Prótese Auditiva para Indivíduos Adultos e Idosos
Juliana Harumi Iwahashi
*   Master in Health Sciences from the Medical School of the University of Sao Paulo. Phonoaudiology at Otorhinolaryngology Foundation.
,
Isabela de Souza Jardim
**   Doctor in Sciences from the Medical School of the University of Sao Paulo. Phonoaudiology at Otorhinolaryngology Foundation.
,
Carina Stábile Sizenando
***   Progress in Cochlear Implant from the Clinical Hospital of the Medical School of the University of Sao Paulo.. Clinic Phonoaudiology.
,
Ricardo Ferreira Bento
****   Main Professor at the Medical School of the University of Sao Paulo.
› Author Affiliations
Further Information

Publication History

18 May 2010

18 July 2010

Publication Date:
12 February 2014 (online)

Summary

Introduction: The hearing aids are one of the options used in auditory rehabilitation with the objective to improve communication and to minimize the limitations caused by hearing loss. Despite the development of technology, the selection and fitting processes demand specific procedures which goal is to maximize performance, benefit and user' satisfaction.

Aim: To describe the hearing aid selecting and fitting protocol for adults and the elderly in an audiological center, which development was based on previously described and validated protocols from the specific literature and information based on clinical practice.

Conclusions: The Hearing Aid Selecting and Fitting Protocol for adults and elder subjects showed that a greater amount of collected information provides better expectations for the patients' real life and greater effectiveness in counseling about hearing aids use, promoting maximum auditory performance, satisfaction and benefit to users.

Resumo

Introdução: A prótese auditiva é uma das alternativas utilizadas no processo de reabilitação auditiva que visa auxiliar a comunicação e minimizar as limitações causadas pela deficiência auditiva. Mesmo com o avanço da tecnologia, a seleção e adaptação da prótese auditiva exigem um processo criterioso para maximizar o desempenho, benefício e satisfação do usuário.

Objetivo: Descrever o protocolo de seleção e adaptação de prótese auditiva para candidatos adultos e idosos utilizado em um centro de audiologia, cuja elaboração foi embasada em protocolos validados e descritos previamente na literatura científica específica e complementada por informações de evidências clínicas do serviço.

Comentários Finais: O protocolo fonoaudiológico de seleção e adaptação da prótese auditiva para adultos e idosos demonstra que um maior número de informações coletadas propicia melhor orientação da expectativa real e maior efetividade no aconselhamento ao uso da prótese auditiva, favorecendo, desta maneira, o desempenho auditivo, a satisfação e o benefício do indivíduo.

 
  • Bibliographical References

  • 1 Matas CG, Iório MCM. Verificação e validação do processo de seleção e adaptação de próteses auditivas. In: Almeida K, Iório MCM. Próteses auditivas: fundamentos teóricos e aplicações clínicas. 2ª ed. São Paulo: Lovise; 2003. , pp. 306–22
  • 2 Meister H, Walger M, Brehmer D, Wede U, Wedel H. The relationship between pre-fitting expectations and willingness to use hearing aids. Int J Audiol 2008; 47 (4) 153-9
  • 3 Kochkin S. MarkeTrak V: “Why my hearing aids are in the drawer”: The consumers' perspective. Hear J 2000; 53 (2) 34-41
  • 4 Goggins S, Day J. Efficacy of recalling adult hearing aid users for reassessment after three years within a publicy-funded audiology service. Int J Audiol 2009; 48: 204-10
  • 5 Sinks BC, Duddy D. Hearing aid orientation and counseling. In: Valente M. Strategies for Selecting and Verifying Hearing Aid Fittings. 2ª ed. New York: Thieme Medical Publishers; 2002. , pp. 345–68
  • 6 Citron III D. Counseling and orientation towards amplification. In: Valente M, Hosford-Dumh Roeser RJ. Audiology Treatment. 2ª ed. New York: Thieme Medical Publishers; 2002. , pp. 292–343
  • 7 Mueller G. Fitting test protocols are 2 more honored in the breach than the observance. Hear J 2003; 56 (10) 112-24
  • 8 Brasil. Ministério da Saúde. Portaria N° 587 de 7 de outubro de 2004, Anexo IV. 2004. Disponível em: portal.saude.gov.br/portal/sas/sapd/visualizar_texto.cfm?idtxt=22642
  • 9 International Society of Audiology. Good practice guidance for adult hearing aid fittings and services - Background to the document and consultation. 2005. Disponível em: www.isa-audiology.org/members/pdf/GPG-ADAF.pdf
  • 10 Russo ICP, Almeida K, Freire KGM. Seleção e Adaptação da Prótese Auditiva para o Idoso. In: Almeida K, Iório MCM. Próteses auditivas: fundamentos teóricos e aplicações clínicas. 2ª ed. São Paulo: Lovise; 2003. , pp. 385–410
  • 11 Cox RM. “Waiting for evidence-based practice for your fittings? It's here”. Hear J 2004; 57 (8) 10-7
  • 12 Mueller HG: Speech audiometry and hearing aid fittings: Going steady or casual acquaintances?. Hear J 2001; 54 (10) 19-29
  • 13 Mueller GH, Bentler RA, Wu YH. Prescribing maximum hearing aid output: differences among manufacturers found. Hear J 2008; 61 (3) 30-6
  • 14 Ferrari GMS, Sanchez TG, Pedalini MEB. A eficácia do molde aberto para o controle do zumbido. Rev Bras Otorrinolaringol 2007; 73 (3) 370-7
  • 15 Paulin F, Zeigelboim BS, Klagenberg KF, Rosa MRD. Achados vestibulares em usuários de aparelho de amplificação sonora individual. Rev CEFAC 2009; 11 (1) 68-75
  • 16 Goebel J, Valente M, Valente M, Enrietto J, Layton KM, Wallace MS. Fitting Strategies for Patients with Conductive or Mixed Hearing Loss. In: Valente M. Strategies for Selecting and Verifying Hearing Aid Fittings. 2ª ed. New York: Thieme Medical Publishers; 2002. , pp. 272–86
  • 17 Souza CD, Glasscock ME. Hearing Aids and Otosclerosis. In: Souza CD, Glasscock ME. Otosclerosis and Stapedectomy: diagnosis, management and complications. New York: Thieme Medical Publishers; 2004. , pp. 69–72
  • 18 Arlinger S. Negative consequences of uncorrected hearing loss - a review. Int J Audiol 2003; 2: 17-20
  • 19 Pupo AC, Pirana S, Spinelli M, Lezirovitz K, Netto RCM, Macedo LS. Estudo de família brasileira portadora de deficiência auditiva sensorioneural não-sindrômica com herança mitocondrial. Rev Bras Otorrinolaringol 2008; 74 (5) 786-9
  • 20 Meding B, Ringdahl A. Allergic Contact Dermatitis from the Earmolds of Hearing Aids. Ear and Hear 1992; 13 (2) 122-4
  • 21 Maia CAS, Campos CAH. Diabetes Melittus como causa de perda auditiva. Rev Bras Otorrinolaringol 2005; 71 (2) 209-14
  • 22 Mondelli MFCG, Lopes AC. Relação entre a Hipertensão Arterial e a Deficiência Auditiva. Arq Int Otorrinolaringol 2009; 13 (1) 63-8
  • 23 Machado JAVP, Tôrres GM, Barcellos NA, Valle LT, Teixeira L, Fonseca MT. Incidência de Sintomas Otológicos em Pacientes Submetidos a Hemodiálise. Arq Int Otorrinolaringol 2006; 10 (1) 62-6
  • 24 Hall CM. Clinical experience using a hearing aid for TMJ-related fitting problems. Hear Rev 2004; 11 (4) 50-3
  • 25 Dillon H, James A, Ginis J. Client Oriented Scale of Improvement (COSI) and its relationship to several other measures of benefit and satisfaction provided by hearing aids. J Am Acad Audiol 1997; 8 (1) 27-43
  • 26 Russo ICP, Lopes LQ, Bruntto-Borgianni LMB, Brasil LA. Logoaudiometria. In: Momenshon-Santos TM, Russo ICP. Prática da audiologia clínica. 5ª ed. São Paulo: Cortez; 2005. , pp. 135–54
  • 27 Costa MJ, Iório MCM, Mangabeira-Albernaz PL. Desenvolvimento de um teste para avaliar a habilidade de reconhecer a fala no silêncio e no ruído. Pró-fono 2000; 12 (2) 9-16
  • 28 Ross T, Smith KE. How to use live speech mapping as part of a hearing fitting and verification protocol. Hear R 2005; 12 (6) 40-6
  • 29 Mueller HG. Data logging: It's popular, but how can this feature be used to help patients?. Hear J 2007; 60 (10) 19-26
  • 30 Cox RM, Alexander GC. Validation of the SADL questionnaire. Ear Hear 2001; 222 (2) 151-60