Vet Comp Orthop Traumatol 2013; 26(05): 416-420
DOI: 10.3415/VCOT-12-10-0134
Case Report
Schattauer GmbH

Minimally invasive plate osteosythesis of fractures of the radius and ulna in a primate

K. Tong
1   Dallas Veterinary Surgical Center, Dallas, Texas, USA
,
L. P. Guiot
1   Dallas Veterinary Surgical Center, Dallas, Texas, USA
› Author Affiliations
Further Information

Publication History

Received 25 October 2013

Accepted 29 January 2013

Publication Date:
23 December 2017 (online)

Summary

A 25-year-old female mandrill (Mandrillus sphinx - a primate and part of the Old World monkey group) was presented with a mildly comminuted, diaphyseal, radial fracture associated with a transverse ulnar fracture. Minimally invasive plate osteosynthesis techniques were used to achieve fixation of both the radial and the ulnar fractures. First, closed fracture reduction was achieved with a distraction frame consisting of a motorized circular external skeletal fixator. Next, dual percutaneous radio-ulnar plating was performed using a 2.7 limited-contact dynamic compression plate on the cranial aspect of the radius and two stacked 2.0/2.7 veterinary cut-to-length plates on the lateral aspect of the ulna. Uncomplicated recovery was observed with a complete return to normal activity three months postoperatively. Fracture healing was documented at four weeks, clinical union at 14 weeks, and callus remodelling at 24 weeks postoperatively. This report demonstrates the feasibility of minimally invasive plate osteosynthesis in a primate and shows the adaptability of this technique across mammalian species.

 
  • References

  • 1 Fox DJ. Radius and Ulna. In: Tobias KM, Johnston SA. editors. Veterinary Surgery, Small Animal. Saint Louis, MO: Saunders; 2012. p. 2012-777.
  • 2 Milovancev M, Ralphs SC. Radius/Ulna fracture repair. Clin Tech Small Anim Pract 2004; 19: 128-133.
  • 3 Beale BS, Pozzi A. Minimally invasive fracture repair. Vet Clin North Am Small Anim Pract 2012; 42: xi-xii.
  • 4 Guiot LP, Dejardin LM. Prospective evaluation of minimally invasive plate osteosynthesis in 36 nonarticular tibial fractures in dogs and cats. Vet Surg 2011; 40: 171-182.
  • 5 Hudson CC, Lewis DD, Pozzi A. Minimally invasive plate osteosynthesis in small animals: radius and ulna fractures. Vet Clin North Am Small Anim Pract 2012; 42: 983-996.
  • 6 Hudson CC, Pozzi A, Lewis DD. Minimally invasive plate osteosynthesis: applications and techniques in dogs and cats. Vet Comp Orthop Traumatol 2009; 22: 175-182.
  • 7 Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 2002; 84: 1093-1110.
  • 8 Schmokel HG, Stein S, Radke H. et al. Treatment of tibial fractures with plates using minimally invasive percutaneous osteosynthesis in dogs and cats. J Small Anim Pract 2007; 48: 157-160.
  • 9 Witsberger TH, Hulse DA, Kerwin SC. et al. Minimally invasive application of a radial plate following placement of an ulnar rod in treating antebrachial fractures. Technique and case series. Vet Comp Orthop Traumatol 2010; 23: 459-467.
  • 10 Pozzi A, Risselada M, Winter MD. Assessment of fracture healing after minimally invasive plate osteosynthesis or open reduction and internal fixation of coexisting radius and ulna fractures in dogs via ultrasonography and radiography. J Am Vet Med Assoc 2012; 241: 744-753.
  • 11 Nowak RM. Primates of the World. Baltimore, Maryland: The Johns Hopkins University Press; 1999
  • 12 Behnke NM, Redjal HR, Nguyen VT. et al. Internal fixation of diaphyseal fractures of the forearm: a retrospective comparison of hybrid fixation versus dual plating. J Orthop Trauma 2012; 26: 611-616.