J Am Acad Audiol 2005; 16(01): 005-017
DOI: 10.3766/jaaa.16.1.2
Articles
American Academy of Audiology. All rights reserved. (2005) American Academy of Audiology

Predicting Pure-Tone Thresholds with Dichotic Multiple Frequency Auditory Steady State Responses

Dunay Schmulian
,
DeWet Swanepoel
,
René Hugo
Further Information

Publication History

Publication Date:
07 August 2020 (online)

The accuracy of dichotic multiple frequency auditory steady state in predicting pure-tone thresholds at 0.5, 1, 2, and 4.0 kHz compared to an ABR protocol (click and tone burst at 0.5 kHz) were explored in a group of 25 hearing-impaired subjects across the degree and configuration spectrum. Mean steady state thresholds were within 14, 18, 15, and 14 dB of the pure tones at 0.5, 1, 2, and 4 kHz, compared to the tone-burst ABR at 0.5 kHz pure-tone difference of 24 dB, and a click-evoked pure-tone (2–4 kHz) difference of 9 dB. Recording time for the steady state protocol was 28 minutes (+/-11) compared to 24 minutes (+/- 9) of the ABR protocol. Degree of loss had a significant effect on steady state; configuration of hearing loss had a limited effect. Mf ASSR predicted thresholds with relative accuracy although some configurations showed discrepancies for low-frequency estimates.