European Journal of General Dentistry, Table of Contents CC BY-NC-ND 4.0 · European Journal of General Dentistry 2012; 1(03): 174-177DOI: 10.4103/2278-9626.105382 Original Article In vivo cytotoxicity of injection molded and conventional pressure pack acrylic resin dentures Ali Riza Tunçdemir Department of Prosthodontics, Faculty of Dentistry, Faculty of Veterinary, Mustafa Kemal University, Hatay, Turkiye , Ahmet Koç 1 Department of Embriology, Faculty of Veterinary, Mustafa Kemal University, Hatay, Turkiye , Serdar Polat Department of Prosthodontics, Faculty of Dentistry, Faculty of Veterinary, Mustafa Kemal University, Hatay, Turkiye , H. Önder Gümüş 2 Department of Prosthodontics, Faculty of Dentistry, Faculty of Veterinary, Mustafa Kemal University, Hatay, Turkiye , Mehmet Dalkiz Department of Prosthodontics, Faculty of Dentistry, Faculty of Veterinary, Mustafa Kemal University, Hatay, Turkiye › Author Affiliations Recommend Article Abstract PDF Download Abstract Context: Acrylic resins are widely used in the fabrication of denture bases and have been shown to be cytotoxic as a result of substances that leach from the resin. Aim: The purpose of this study was to compare the cytotoxicity of the injectionmolded and conventional pressure-pack heat polymerized acrylic base resin systems with evaluation of the micronucleus frequency on the oral mucosa of the participants. Materials and Methods: This study was carried out by examining the 20 patients′ buccal mucosa who begin to use complete dentures that fabricated by different heat polymerized systems. The micronucleus incidence was scored in the buccal epithelial of each patients. Epithelial cells were collected from oral mucosa by a wooden spatula before applying the prosthesis in the mouth, after 1 week and 1 month and they were smeared on to clean microscope glass slides then examined under light microscope. Results: Micronucleus frequency was higher in individuals′ buccal mucosa who used conventional press pack dentures than injection molded heat polymerized groups. There was not statistically significant differences between conventional and injection molded heat polymerized groups (P>0.05). Number of micronucleus at the end of the 1 week was much more than after 1 month for each groups. Conclusion: Complete dentures that fabricated by injection molded denture base materials is less cytotoxic than conventional pressure pack acrylic resin. Keywords KeywordsAcrylic resin - cytotoxicity - original article - polymerization method - residual monomer PDF (610 kb) References References 1 Ozkan AS, Yavuzyilmaz H. In vitro comparison of the cytotoxicity of acetal resin, heat-polymerized resin, and auto-polymerized resin as denture base. J Biomed Mater Res Part B Appl Biomater 2009;91:905-9. 2 Park JB. Biomaterials. In: Bronzino JD, editor. Biomedical Engineering Handbook. Boca Raton: CRC Press; 1995. p. 530-610. 3 Craig RG, Powers JM. Restorative Dental Materials. 11 th ed. St. Louis, MO: Mosby; 2002. p. 636-89. 4 Parvizi A, Schneider R, Boyer D. Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin. J Prosthodont 2004;13:83-9. 5 Bohnenkamp DM. Traumatic stomatitis following an intraoral denture reline: A clinical report. J Prosthet Dent 1996;76:113-4. 6 Lunder T, Rogl-Butina M. Chronic urticaria from an acrylic dental prosthesis. Contact Dermatitis 2000;43:232-3. 7 Sadamori S, Kotani H, Hamada T. The usage period of dentures and their residual monomer contents. J Prosthet Dent 1992;68:374-6. 8 Koda T, Tsuchiya H, Yamauchi M, Ohtani S, Tagaki N, Kawano J. Leachability of denture base acrylic resins in artificial saliva. Dent Mater 1990;6:13-6. 9 Garfunkel E. Evaluation of dimensional changes in complete dentures processed by injection- pressing and the pack-and-press technique. J Prosthet Dent 1983;50:75761. 10 Anderson GC, Schulte JK, Arnold TG. Dimensional stability of injection and conventional processing of denture base acrylic resin. J Prosthet Dent 1988;60:394-8. 11 Cimpan MR, Matre R, Cressey LI, Tysnes B, Lie SA, Gjertsen BT, et al. The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: Denture base polymers induce apoptosis and necrosis. Acta Odontol Scand 2000;58:217-28. 12 Blagojevic V, Murphy VM. Microwave polymerization of denture base materials. A comparative study. J Oral Rehabil 1999;26:804-8. 13 Hedle JA, Hite M, Kirkhart B, Mavaurnin K, Macgragor JT, Newell GW, et al. The induction of micronuclei as a measure of genotoxicity. A report of the U.S. Enviremental Protection Agency Gene-Tox Program. Mutat Res 1983;123:61-118. 14 Stitch HF, Rosin MP, Vallejera MO. Reduction with vitamin A and beta-carotene administration of proportion of micronucleated buccal mucosal cells in Asian betel nut and tobacco chewers. Lancet 1984;1:1204-6. 15 Adhvaryu SG, Dave BJ, Trivedi AH. Cytogenetic surveillance of tobacco-areca nut (mava) chewers. Mutat Res 1991;261:41-9. 16 Roberts DM. Comparative cytology of the oral cavities of snuff users. Acta Cytol 1997;41:1008-14. 17 Heil J, Reifferscheid G, Waldmann P, Leyhausen G, Geurtsen W. Genotoxicity of dental materials. Mutat Res 1996;368:181-94. 18 Countryman PI, Heddle JA. The production of micronuclei from chromosome aberrations in irradiated cultures of human lymphocytes. Mutat Res 1976;41:321-32. 19 Thomas PG, Adrian JC, Banks KE, Robinson JA, Peagler FD. Biocompatibilty evaluation of resins in hamsters. J Prosthet Dent 1985;53:428-30. 20 Lamb DJ, Ellis B, Priestley D. The effects of process variables on levels of residual monomer in autopolymerizing acrylic resin. J Dent 1983;11:80-8. 21 Kleinsasser NH, Wallner BC, Harreus UA, Kleinjungb T, Folwacznyc M, Hickelc R, et al. Genotoxicity and cytotoxicity of dental materials in human lymphocytes as assessed by the single cell microgel electrophoresis (comet) assay. J Dent 2004;32:229-34. 22 Harrison A, Hugget R. Effect of curing cycle on residual monomer levels of acrylic resin denture base polymers. J Prosthet Dent 1992;20:370-4. 23 Danilewitz Z. Experimental investigations on the cytotoxic nature of methyl methacrylate. J Prosthet Dent 1980;44:13-6. 24 Sheridan PJ, Koka S, Ewoldsen NO, Lefebvre CA, Lavin MT. Cytotoxicity of denture base resins. Int J Prosthodont 1997;10:73-7. 25 Kedjarune U, Charoenworaluk N, Koontongkaew S. Release of methyl methacrylate from heat-cured and autopolymerized resins: Cytotoxicity testing related to residual monomer. Aust Dent J 1999;44:25-30. 26 Özen J, Sipahi C, Çağlar A, Dalkýz M. In vitro cytotoxicity of glass and carbon fiber-reinforced heat-polymerized acrylic resin denture base material turk. J Med Sci 2006;36:121-6. 27 Parvizi A, Lindquist T, Schneider R, Williamson D, Boyer D, Dawson DV. Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin. J Prosthodont 2004;13:83-9. 28 Hugget R, Zissis A, Harrison A, Dennis A. Dimensional accuracy and stabilty of acrylic resin denture bases. J Prosthet Dent 1992;68:634-40. 29 Tsuchiya H, Hoshino Y, Tajima K, Takagi N. Leaching and cytotoxicity of formaldehyde and methyl methacrylate from a c rylic resin denture base materials. J Prosthet Dent 1994;71:618-24. 30 Tsuchiya H, Yamada K, Akagiri M, Tajima K, Miyazaki T, Takagi N, et al. Effect of an ultraviolet light-activated coating material on reduction of the leaching of methylmethacrylate and formaldehyde from denture acrylic resins. Dent Mater J 1993;12:253-8.