CC BY-NC-ND 4.0 · J Neuroanaesth Crit Care 2016; 03(01): 025-032
DOI: 10.4103/2348-0548.173244
Original Article
Thieme Medical and Scientific Publishers Private Ltd.

Comparison of bispectral index and entropy monitoring in patients undergoing internalisation of deep brain stimulators

Suparna Bharadwaj
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
,
Mahesh Nagappa
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
,
Audrey Tan
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
,
Jigesh Mehta
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
,
Pirjo Manninen
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
,
Lashmi Venkatraghavan
1   Department of Anaesthesia and Critical Care, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada
› Author Affiliations
Further Information

Publication History

Publication Date:
03 May 2018 (online)

Abstract

Introduction: Depth of anaesthesia (DOA) monitors are shown to reduce the intra-operative dose of anaesthetic agents, provide haemodynamic stability and shorten emergence times. Electroencephalography (EEG) based DOA monitors such as bispectral index (BIS) and entropy have been calibrated and validated in healthy subjects. Hence the clinical effectiveness of these monitors may be affected when monitoring patients with neurological disorders (e.g., epilepsy, dystonia, dementia and Parkinson’s disease). The aim of this study was to determine whether BIS and entropy correlate with each other and with clinical indices of DOA in patients with movement disorders under general anaesthesia (GA). Materials and Methods: We conducted a prospective, observational study in patients with movement disorders undergoing internalization of deep brain stimulators. All patients received standard GA with age-adjusted mean alveolar concentration (aaMAC) of an inhalational agent between 0.7 and 1.1. BIS and entropy sensors were applied on the patient’s left forehead. Data collected included clinical parameters and EEG-based DOA indices. Correlation analysis was performed between entropy, BIS and the clinical indices of DOA. Bland Altman analysis was performed to determine the agreement between BIS and entropy. Results: Thirty patients were studied (mean age was 58.4 ± 11 years, male: female 18:12 and weight 79.2 ± 17 kg). Indications for deep brain stimulation were Parkinson’s disease (n = 25), essential tremors (n = 2) and dystonia (n = 3). There was a very strong positive correlation between BIS and response entropy (RE) (r = 0.932) and BIS and state entropy (SE) (r = 0.950) and a strong negative correlation among aaMAC and BIS, RE and SE with r values of −0.686, −0.788 and −0.732, respectively. However, there was no correlation between BIS, RE, SE and haemodynamic values. Conclusion: Our study showed that BIS and entropy perform well in patients with movement disorders. There was a good correlation between the BIS and entropy devices. Haemodynamic parameters were not reliable indicators of DOA in these patients.

 
  • REFERENCES

  • 1 Palanca BJ, Mashour GA, Avidan MS. Processed electroencephalogram in depth of anesthesia monitoring. Curr Opin Anaesthesiol 2009; 22: 553-9
  • 2 Punjasawadwong Y, Boonjeungmonkol N, Phongchiewboon A. Bispectral index for improving anaesthetic delivery and postoperative recovery. Cochrane Database Syst Rev 2007; 17: CD003843
  • 3 Klopman MA, Sebel PS. Cost-effectiveness of bispectral index monitoring. Curr Opin Anaesthesiol 2011; 24: 177-81
  • 4 Monk TG. Processed EEG and patient outcome. Best Pract Res Clin Anaesthesiol 2006; 20: 221-8
  • 5 Johansen JW, Sebel PS, Sigl JC. Clinical impact of hypnotic-titration guidelines based on EEG bispectral index (BIS) monitoring during routine anesthetic care. J Clin Anesth 2000; 12: 433-43
  • 6 Smith D, Andrzejowski J, Smith A. Certainty and uncertainty: NICE guidance on ‘depth of anaesthesia’ monitoring. Anaesthesia 2013; 68: 1000-5
  • 7 Shepherd J, Jones J, Frampton G, Bryant J, Baxter L, Cooper K. Clinical effectiveness and cost-effectiveness of depth of anaesthesia monitoring (E-Entropy, Bispectral Index and Narcotrend): A systematic review and economic evaluation. Health Technol Assess 2013; 17: 1-264
  • 8 Viertiö-Oja H, Maja V, Särkelä M, Talja P, Tenkanen N, Tolvanen-Laakso H. et al. Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy module. Acta Anaesthesiol Scand 2004; 48: 154-61
  • 9 Sebel PS, Bowdle TA, Ghoneim MM, Rampil IJ, Padilla RE, Gan TJ. et al. The incidence of awareness during anesthesia: A multicenter United States study. Anesth Analg 2004; 99: 833-9
  • 10 Arnold G, Kluger M, Voss L, Sleigh J. BIS and Entropy in the elderly. Anaesthesia 2007; 62: 907-12
  • 11 Fonseca LC, Tedrus GM, Letro GH, Bossoni AS. Dementia, mild cognitive impairment and quantitative EEG in patients with Parkinson's disease. Clin EEG Neurosci 2009; 40: 168-72
  • 12 Bonanni L, Thomas A, Tiraboschi P, Perfetti B, Varanese S, Onofrj M. EEG comparisons in early Alzheimer's disease, dementia with Lewy bodies and Parkinson's disease with dementia patients with a 2-year follow-up. Brain 2008; 131 (Pt 3) 690-705
  • 13 Venkatraghavan L, Luciano M, Manninen P. Review article: Anesthetic management of patients undergoing deep brain stimulator insertion. Anesth Analg 2010; 110: 1138-45
  • 14 Tallach RE, Ball DR, Jefferson P. Monitoring seizures with the bispectral index. Anaesthesia 2004; 59: 1033-4
  • 15 White PF, Rawal S, Recart A, Thornton L, Litle M, Stool L. Can the bispectral index be used to predict seizure time and awakening after electroconvulsive therapy?. Anesth Analg 2003; 96: 1636-9
  • 16 Dahaba AA. Different conditions that could result in the bispectral index indicating an incorrect hypnotic state. Anesth Analg 2005; 101: 765-73
  • 17 Pemberton P, Dinsmore J. Bispectral index monitoring during awake craniotomy surgery. Anaesthesia 2002; 43: 708-10
  • 18 Renna M, Handy J, Shah A. Low baseline bispectral index of the electroencephalogram in patients with dementia. Anesth Analg 2003; 96: 1380-5
  • 19 Ozlu O, Sanalbas S, Yazicioglu D, Utebey G, Baran I. Sedation and regional anesthesia for deep brain stimulation in Parkinson's disease. J Anesthesiol 2014; 2014: 6
  • 20 Paolo Martorano P, Falzetti G, Pelaia P. Bispectral index and spectral Entropy in neuroanesthesia. J Neurosurg Anesthesiol 2006; 18: 205-10
  • 21 Moonesinghe SR, Walker EM, Bell M. SNAP – Investigator Group. Design and methodology of SNAP-1: A sprint national anaesthesia project to measure patient reported outcome after anaesthesia. Perioper Med (Lond) 2015; 4: 4
  • 22 Kaskinoro K, Maksimow A, Långsjö J, Aantaa R, Jääskeläinen S, Kaisti K. et al. Wide inter-individual variability of bispectral index and spectral Entropy at loss of consciousness during increasing concentrations of dexmedetomidine, propofol, and sevoflurane. Br J Anaesth 2011; 107: 573-80
  • 23 Punjasawadwong Y, Phongchiewboon A, Bunchungmongkol N. Bispectral index for improving anaesthetic delivery and postoperative recovery. Cochrane Database Syst Rev 2014; 6
  • 24 Chan MT, Cheng BC, Lee TM, Gin T. CODA Trial Group. BIS-guided anesthesia decreases postoperative delirium and cognitive decline. J Neurosurg Anesthesiol 2013; 25: 33-42
  • 25 Mustafa HI, Fessel JP, Barwise J, Shannon JR, Raj SR, Diedrich A. et al. Dysautonomia: Perioperative implications. Anesthesiology 2012; 116: 205-15
  • 26 Strøm C, Rasmussen LS, Sieber FE. Should general anaesthesia be avoided in the elderly?. Anaesthesia 2014; 69 Suppl (Suppl. 01) 35-44
  • 27 Deogaonkar A, Gupta R, DeGeorgia M, Sabharwal V, Gopakumaran B, Schubert A. et al. Bispectral index monitoring correlates with sedation scales in brain-injured patients. Crit Care Med 2004; 32: 2403-6