CC BY-NC-ND 4.0 · Asian J Neurosurg 2021; 16(01): 56-61
DOI: 10.4103/ajns.AJNS_503_20
Original Article

Safety and effectiveness of a modified ASAP technique during mechanical thrombectomy for acute ischemic stroke: Initial clinical experience

Tomotaka Ohshima
1   Neuroendovascular Therapy Center, Aichi Medical University, Nagakute, Aichi
,
Reo Kawaaguchi
2   Department of Neurosurgery, Aichi Medical University, Nagakute, Aichi
,
Naoki Matsuo
2   Department of Neurosurgery, Aichi Medical University, Nagakute, Aichi
,
Shigeru Miyachi
1   Neuroendovascular Therapy Center, Aichi Medical University, Nagakute, Aichi
2   Department of Neurosurgery, Aichi Medical University, Nagakute, Aichi
› Author Affiliations

Objectives: For patients with acute ischemic stroke, various endovascular approaches have been reported with high recanalization rates and good clinical outcomes. However, the best technique for the first attempt at mechanical thrombectomy remains a matter of debate. In this study, we evaluated the efficacy of a modified version of a stent-retrieving into an aspiration catheter with a proximal balloon (ASAP) technique. Materials and Methods: Modification 1: After stent deployment, the microcatheter was not removed immediately. Modification 2: After the withdrawal of the stent retriever into an aspirator and its removal from the entire system, we focused on the drainage of fluid into a pump. The aspirator was withdrawn slowly until the fluid appeared to be draining continuously into the pump. Before the removal of the aspirator, we performed angiography through the aspirator. We carried out a retrospective analysis of 30 consecutive patients with acute ischemic stroke caused by occlusion of the anterior circulation who were treated with the modified ASAP technique at our institution. Results: A thrombolysis in cerebral infarction score of 2B or 3 was achieved in 29/30 patients (96.7%). The average number of passes was 1.2 ± 0.5. The mean time from puncture to recanalization was 17.6 ± 6.84 min. Twenty-three (76.7%) patients achieved a modified Rankin Scale score of 0–2 at 3 months after the procedure. Conclusions: We found that the modified ASAP technique yielded fast recanalization, minimal complications, and good clinical outcomes of mechanical thrombectomy in this case series.

Financial support and sponsorship

Nil.




Publication History

Received: 23 November 2020

Accepted: 26 January 2021

Article published online:
16 August 2022

© 2021. Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Goyal M, Demchuk AM, Menon BK, Eesa M, Rempel JL, Thornton J, et al. Randomized assessment of rapid endovascular treatment of ischemic stroke. N Engl J Med 2015;372:1019-30.
  • 2 Mueller-Kronast NH, Zaidat OO, Froehler MT, Jahan R, Aziz-Sultan MA, Klucznik RP, et al. Systematic evaluation of patients treated with neurothrombectomy devices for acute ischemic stroke: Primary results of the STRATIS registry. Stroke 2017;48:2760-8.
  • 3 Turk AS, Frei D, Fiorella D, Mocco J, Baxter B, Siddiqui A, et al. ADAPT FAST study: A direct aspiration first pass technique for acute stroke thrombectomy. J Neurointerv Surg 2014;6:260-4.
  • 4 Delgado Almandoz JE, Kayan Y, Young ML, Fease JL, Scholz JM, Milner AM, et al. Comparison of clinical outcomes in patients with acute ischemic stroke treated with mechanical thrombectomy using either Solumbra or ADAPT techniques. J Neurointerv Surg 2016;8:1123-8.
  • 5 Humphries W, Hoit D, Doss VT, Elijovich L, Frei D, Loy D, et al. Distal aspiration with retrievable stent assisted thrombectomy for the treatment of acute ischemic stroke. J Neurointerv Surg 2015;7:90-4.
  • 6 McTaggart RA, Tung EL, Yaghi S, Cutting SM, Hemendinger M, Gale HI, et al. Continuous aspiration prior to intracranial vascular embolectomy (CAPTIVE): A technique which improves outcome. J NeuroInturv Surg 2016;9:1-6.
  • 7 Maus V, Behme D, Kabbasch C, Borggrefe J, Tsogkas I, Nikoubashman O, et al. Maximizing first-pass complete reperfusion with SAVE. Clin Neuroradiol 2018;28:327-38.
  • 8 Massari F, Henninger N, Lozano JD, Patel A, Kuhn AL, Howk M, et al. ARTS (aspiration-retriever technique for stroke): Initial clinical experience. Interv Neuroradiol 2016;22:325-32.
  • 9 Goto S, Ohshima T, Ishikawa K, Yamamoto T, Shimato S, Nishizawa T, et al. A stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique: A technique of mechanical thrombectomy. World Neurosurg 2018;109: e468-e475.
  • 10 Ohshima T, Niwa A, Kawaguchi R, Matsuo N, Miyachi S. Novel technique for detection of actual position of clot during endovascular clot retrieval: Assessment of microcatheter withdrawing angiography. World Neurosurg 2020;137:229-34.
  • 11 Lyden PD, Lu M, Levine SR, Brott TG, Broderick J, NINDS rtPA Stroke Study Group. A modified National Institutes of Health Stroke Scale for use in stroke clinical trials: Preliminary reliability and validity. Stroke 2001;32:1310-7.
  • 12 Hirai T, Sasaki M, Maeda M, Ida M, Katsuragawa S, Sakoh M, et al. Diffusion-weighted imaging in ischemic stroke: Effect of display method on observers' diagnostic performance. Acad Radiol 2009;16:305-12.
  • 13 Higashida R, Furlan A, Roberts H, Tomsick T, Connors B, Barr J, et al. Trial design and reporting standards for intraarterial cerebral thrombolysis for acute ischemic stroke. J Vasc Interv Radiol 2003;14:S493-4.
  • 14 Sato M, Ohshima T, Ishikawa K, Goto S, Yamamoto T, Izumi T, et al. A novel technique of safe and versatile microguidewire shaping with neuroendovascular therapy: Modified pigtail method. J Neuroendovasc Ther 2017;11:266-71.
  • 15 Ohshima T, Ishikawa K, Goto S, Yamamoto T. Relationship between clot quality and microguidewire configuration during endovascular thrombectomy for acute ischemic stroke. World Neurosurg 2017;107:657-62.
  • 16 Ohshima T, Kawaguchi R, Maejima R, Yukiue N, Matsuo N, Miyachi S. Initial clinical experience of using a newly designed preshaped microguidewire in acute endovascular thrombectomy. Asian J Neurosurg 2020;15:241-4.
  • 17 Goyal M, Menon BK, van Zwam WH, Dippel DW, Mitchell PJ, Demchuk AM, et al. Endovascular thrombectomy after large-vessel ischaemic stroke: A meta-analysis of individual patient data from five randomized trials. Lancet 2016;387:1723-31.