CC BY-NC-ND 4.0 · Eur J Dent 2018; 12(01): 089-093
DOI: 10.4103/ejd.ejd_231_17
Original Article
Dental Investigation Society

Increase the glyde path diameter improves the centering ability of F6 Skytaper

Giuseppe Troiano
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
,
Mario Dioguardi
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
,
Armando Cocco
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
,
Khrystyna Zhurakivska
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
,
Domenico Ciavarella
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
,
Lorenzo Lo Muzio
1   Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
› Author Affiliations
Further Information

Publication History

Publication Date:
13 September 2019 (online)

ABSTRACT

Objective: The aim of this study was to assess the impact of glide path preparation, performed with PathGlider 0.15 (Komet Brasseler GmbH & Co., Lemgo, Germany) and PathGlider 0.20 (Komet Brasseler GmbH & Co., Lemgo, Germany), on the centering ability of 25-size F6 Skytaper in J-shape simulated root canals, compared with no glide path executed. Materials and Methods: Sixty J-shaped ISO 15 0.02 taper endo training blocks (Dentsply Maillefer) were assigned to three groups (n = 20 for each group). Photographic images were taken on endoblocks before and after shaping procedures. After superimposition, the software AutoCAD 2013 (Autodesk Inc., San Rafael, USA) was used for record the centering and shaping ability at 9 different levels from the apex. Results: Shaping procedures including the using of PathGlider 0.20 resulted in a lower amount of resin removed and in a clear improvement of centering ability of the Skytaper 0.25 at almost all reference point levels. Conclusions: Within the limitations of this study, it could be concluded that the glide path procedure, performed with the PathGlider 0.20 before the shaping with 25-size F6 Skytaper, might determine a lower amount of resin removed and a better centering ability compared with the groups without glide path procedure and those treated with PathGlider 0.15.

 
  • REFERENCES

  • 1 Thompson SA, Dummer PM. Shaping ability of proFile 04 taper series 29 rotary nickel-titanium instruments in simulated root canals. Part 1.. Int Endod J 1997; 30: 1-7
  • 2 Pruett JP, Clement DJ, Carnes Jr. DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997; 23: 77-85
  • 3 You SY, Kim HC, Bae KS, Baek SH, Kum KY, Lee W. et al. Shaping ability of reciprocating motion in curved root canals: A comparative study with micro-computed tomography. J Endod 2011; 37: 1296-300
  • 4 Peters OA. Current challenges and concepts in the preparation of root canal systems: A review. J Endod 2004; 30: 559-67
  • 5 Yared G. Canal preparation using only one ni-ti rotary instrument: Preliminary observations. Int Endod J 2008; 41: 339-44
  • 6 Troiano G, Dioguardi M, Cocco A, Giuliani M, Fabiani C, D’ Alessandro A. et al. Centering ability of ProTaper next and WaveOne classic in J-shape simulated root canals. ScientificWorldJournal 2016; 2016: 1606013
  • 7 Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012; 45: 449-61
  • 8 Letters S, Smith AJ, McHugh S, Bagg J. A study of visual and blood contamination on reprocessed endodontic files from general dental practice. Br Dent J 2005; 199: 522-5
  • 9 Bürklein S, Poschmann T, Schäfer E. Shaping ability of different nickel-titanium systems in simulated S-shaped canals with and without glide path. J Endod 2014; 40: 1231-4
  • 10 Vallaeys K, Chevalier V, Arbab-Chirani R. Comparative analysis of canal transportation and centring ability of three Ni-Ti rotary endodontic systems: Protaper(R), MTwo(R) and Revo-S, assessed by micro-computed tomography. Odontology 2016; 104: 83-8
  • 11 Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod 2012; 38: 1618-21
  • 12 Troiano G, Dioguardi M, Cocco A, Giannatempo G, Laino L, Ciavarella D. et al. Influence of operator's experience on the shaping ability of protaper universal and waveone systems: A Comparative study on simulated root canals. Open Dent J 2016; 10: 546-52
  • 13 Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G. et al. Use of nickel-titanium rotary pathFile to create the glide path: Comparison with manual preflaring in simulated root canals. J Endod 2009; 35: 408-12
  • 14 Ajuz NC, Armada L, Gonçalves LS, Debelian G, Siqueira Jr. JF. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments. J Endod 2013; 39: 534-7
  • 15 Yang GB, Zhou XD, Zhang H, Wu HK. Shaping ability of progressive versus constant taper instruments in simulated root canals. Int Endod J 2006; 39: 791-9
  • 16 Schäfer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile – Part 1. Shaping ability in simulated curved canals. Int Endod J 2002; 35: 505-13
  • 17 Peters OA, Laib A, Göhring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod 2001; 27: 1-6
  • 18 Dioguardi M, Troiano G, Laino L, Lo Russo L, Giannatempo G, Lauritano F. et al. ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals. Int J Clin Exp Med 2015; 8: 17830-4
  • 19 Bonaccorso A, Cantatore G, Condorelli GG, Schäfer E, Tripi TR. Shaping ability of four nickel-titanium rotary instruments in simulated S-shaped canals. J Endod 2009; 35: 883-6
  • 20 Zhang L, Luo HX, Zhou XD, Tan H, Huang DM. The shaping effect of the combination of two rotary nickel-titanium instruments in simulated S-shaped canals. J Endod 2008; 34: 456-8
  • 21 Dhingra A, Nagar N, Sapra V. Influence of the glide path on various parameters of root canal prepared with WaveOne reciprocating file using cone beam computed tomography. Dent Res J (Isfahan) 2015; 12: 534-40
  • 22 Gergi RM, Osta NE, Naaman AS. Dentinal crack formation during root canal preparations by the twisted file adaptive, reciproc and WaveOne instruments. Eur J Dent 2015; 9: 508-12
  • 23 Türker SA, Uzunoǧlu E. Apical root canal transportation of different pathfinding systems and their effects on shaping ability of ProTaper next. J Clin Exp Dent 2015; 7: e392-5
  • 24 Schäfer E, Diez C, Hoppe W, Tepel J. Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod 2002; 28: 211-6