RSS-Feed abonnieren
DOI: 10.1055/a-1506-2683
Pathological evaluation of a rectal endoscopic submucosal dissection specimen using micro-computed tomography
Gefördert durch: Warren Alpert Foundation, http://dx.doi.org/10.13039/100002558
Gefördert durch: The Cancer Center Support Grant of the National Institutes of Health/National Cancer Institute P30CA008748
Endoscopic submucosal dissection (ESD) is widely used for resecting superficial gastrointestinal neoplasms that are difficult to remove en bloc by conventional endoscopic mucosal resection. After the resected specimen is sectioned into slices a few millimeters thick, slides are created for histologic examination. However, the slides produced represent only a small fraction of the lesion, and there is always the possibility of missing significant findings in the unexamined areas. Micro-computed tomography (micro-CT) is a novel in vitro tomographic method that allows the examination of fresh tissue or paraffin blocks non-destructively with a spatial resolution [1]. Previous studies have shown the potential of micro-CT images in revealing the detailed structures of breast cancer and thyroid cancer [2] [3]. Here we describe a superficial rectal cancer removed by ESD for which micro-CT revealed diagnostic information that was not well visualized on routine histology.
A 51-year-old woman was referred for resection of a laterally spreading tumor in the rectum. The patient underwent ESD and the lesion was removed en bloc. The resected specimen was immersed in 10 % Lugol’s iodine solution for 2 minutes and then scanned with a custom-made micro-CT for 10 minutes (Nikon Metrology NV, Leuven, Belgium) ([Fig. 1]). Thereafter, the specimen was processed following the standard procedure. There was no effect of immersion in iodine on the quality of the slides. Paraffin blocks were also subjected to micro-CT scanning after slide preparation. Micro-CT images clearly showed the submucosal invasion noted on the hematoxylin and eosin (H&E)-stained slide, especially in the block scan ([Fig. 2]). In addition, the micro-CT generated images between the sections that could not be seen with H&E staining ([Video 1]).
Video 1 Micro-computed tomography for an endoscopic submucosal dissection specimen from an early rectal cancer.
Qualität:
In conclusion, micro-CT scanning of fresh ESD specimens and paraffin blocks has the potential to enhance pathological diagnosis by providing a detailed histological structure of the areas that are not represented by standard H&E-stained slides.
Endoscopy_UCTN_Code_TTT_1AQ_2AJ
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.
This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos
#
Competing interests
Hirotsugu Sakamoto has received honoraria and grants from Fujifilm Corporation. Makoto Nishimura has acted as a consultant for Boston Scientifics, Lumendi, and Olympus America. The remaining authors declare that they have no conflict of interest.
Acknowledgments
We thank Peter Ntiamoah, David Beckles, Lina M. Larrahondo, and Marc-Henri Jean for technical assistance.
-
References
- 1 Teplov A, Tabata K, Fu X. et al. Development of standard operating procedure (SOP) of micro-computed tomography (micro-CT) in pathology. Diagn Pathol 2019; 5: 273
- 2 Tang R, Buckley JM, Fernandez L. et al. Micro-computed tomography (Micro-CT): a novel approach for intraoperative breast cancer specimen imaging. Breast Cancer Res Treat 2013; 139: 311-316
- 3 Xu B, Teplov A, Ibrahim K. et al. Detection and assessment of capsular invasion, vascular invasion and lymph node metastasis volume in thyroid carcinoma using microCT scanning of paraffin tissue blocks (3D whole block imaging): a proof of concept. Mod Pathol 2020; 33: 2449-2457
Corresponding author
Publikationsverlauf
Artikel online veröffentlicht:
08. Juni 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Teplov A, Tabata K, Fu X. et al. Development of standard operating procedure (SOP) of micro-computed tomography (micro-CT) in pathology. Diagn Pathol 2019; 5: 273
- 2 Tang R, Buckley JM, Fernandez L. et al. Micro-computed tomography (Micro-CT): a novel approach for intraoperative breast cancer specimen imaging. Breast Cancer Res Treat 2013; 139: 311-316
- 3 Xu B, Teplov A, Ibrahim K. et al. Detection and assessment of capsular invasion, vascular invasion and lymph node metastasis volume in thyroid carcinoma using microCT scanning of paraffin tissue blocks (3D whole block imaging): a proof of concept. Mod Pathol 2020; 33: 2449-2457