Utility of external and internal magnets to facilitate bile duct cannulation by changing the position of the papilla

Yi Mou
Department of Gastroenterology, West China Hospital, Sichuan University Chengdu, Sichuan, P. R. China
,
Long He
Department of Gastroenterology, West China Hospital, Sichuan University Chengdu, Sichuan, P. R. China
,
Bing Hu
Department of Gastroenterology, West China Hospital, Sichuan University Chengdu, Sichuan, P. R. China
› Author Affiliations
Supported by: Sichuan University, West China Hospital, 1·3·5 Project for Disciplines of Excellence ZYJC21011
 

A 75-year-old man attended the emergency department complaining of upper abdominal colic accompanied by nausea and cold sweating for 24 hours. Physical examination found that there was mild tenderness and tension in the upper region of his abdomen. Several of his liver function test and blood chemistry values were abnormal: neutrophil count 7710/µL (reference 2000–7000/µL), total bilirubin 2.1 mg/dL, direct bilirubin 1.3 mg/dL, pancreatic lipase 2085 IU/L. In addition, acute inflammatory markers, including procalcitonin (0.63 ng/mL), IL-6 (287 pg/mL), and C-reactive protein (59.1 mg/mL), were all elevated. A nonenhanced abdominal computed tomography scan indicated the presence of an 8-mm stone in the distal common bile duct ([Fig. 1]).

Zoom Image
Fig. 1 Nonenhanced abdominal computed tomography scan indicating the presence of an 8-mm stone (yellow arrow) in the distal common bile duct of a 75-year-old man.

Endoscopic retrograde cholangiopancreatography (ERCP) was performed on the second day after admission. The duodenoscope reached the descending duodenum smoothly. However, as the angle between the bile duct and cannulation was almost a right angle, possibly caused by a diverticulum, an experienced endoscopist failed to complete biliary cannulation after several attempts ([Fig. 2]). Several days later, a second try was made, this time using magnets to help to tackle the difficult papilla ([Video 1]). A magnetic bead was fixed next to the papilla and a powerful magnet placed externally ([Fig. 3 a, b]). Through the attraction between the magnets, the angle was changed and the biliary cannulation was then successfully performed ([Fig. 3 c, d]). Following cannulation, the sphincter was cut about 5 mm using blended current. Finally, the stone was extracted using a stone basket, and the filling defect disappeared ([Fig. 3 e, f]). There were no complications.

Zoom Image
Fig. 2 Biliary cannulation was not completed at the first session. a A diverticulum (green arrow) is seen beside the papilla. b The angle between the bile duct (blue arrow) and cannulation (red arrow) was almost a right angle.

Video 1 External and internal magnets were used to facilitate bile duct cannulation by changing the position of the papilla.


Quality:
Zoom Image
Fig. 3 The process of successful biliary cannulation. a A magnetic bead (white arrow) was fixed next to the papilla. b A powerful magnet was placed externally. c Biliary cannulation was successfully performed. d Fluoroscopic image: the yellow arrow indicates the stone and the green arrow the magnetic bead. e The stone was extracted. f The filling defect disappeared.

Reports exist of magnets playing an important role in endoscopic surgery [1] [2]. In the present case, biliary cannulation that was difficult using the conventional technique was achieved successfully in a short time with the help of magnets. The advantage of the magnets was that the direction and force of traction could be easily adjusted, which was helpful in tackling the difficult papilla. This technique could be applied to other, similar situations during ERCP.

Endoscopy_UCTN_Code_TTT_1AR_2AK

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.

This section has its own submissionwebsite athttps://mc.manuscriptcentral.com/e-videos


#

Competing interests

The authors declare that they have no conflict of interest.


Corresponding author

Bing Hu, MD
West China Hospital
Sichuan University
No. 37, Guo Xue Alley
Wuhou District
Chengdu City
Sichuan Province
P. R. China   

Publication History

Article published online:
07 March 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany


Zoom Image
Fig. 1 Nonenhanced abdominal computed tomography scan indicating the presence of an 8-mm stone (yellow arrow) in the distal common bile duct of a 75-year-old man.
Zoom Image
Fig. 2 Biliary cannulation was not completed at the first session. a A diverticulum (green arrow) is seen beside the papilla. b The angle between the bile duct (blue arrow) and cannulation (red arrow) was almost a right angle.
Zoom Image
Fig. 3 The process of successful biliary cannulation. a A magnetic bead (white arrow) was fixed next to the papilla. b A powerful magnet was placed externally. c Biliary cannulation was successfully performed. d Fluoroscopic image: the yellow arrow indicates the stone and the green arrow the magnetic bead. e The stone was extracted. f The filling defect disappeared.