An 85-year-old woman presented with right upper abdominal pain and fever. Examination
revealed tenderness in the right hypochondrium with a positive Murphy’s sign. White
cell count was 16.3 × 109/L, but liver function was normal. Transabdominal ultrasound
confirmed acute cholecystitis with a 6-mm cystic duct stone. Owing to the patient’s
pre-existing Alzheimer’s disease and frail pre-morbid condition, we decided for endoscopic
ultrasound-guided gallbladder drainage (EUS-GBD) after discussion with the patient’s
main caregiver [1]
[2]
[3].
The procedure was performed in an endoscopy suite with fluoroscopy capabilities and
the patient was placed in the prone position under conscious sedation ([Video 1]). A linear echoendoscope (GF-UCT260; Olympus, Tokyo, Japan) was advanced to the
first part of the duodenum and a distended gallbladder up to 10 cm and a 6-mm cystic
duct stone were identified ([Fig. 1]). There were no stones in the common bile duct.
Video 1 Use of a novel cautery-enhanced, endoscopist-deployed lumen-apposing metal stent
to perform endoscopic ultrasound-guided gallbladder drainage.
Fig. 1 Endoscopic ultrasound images of a distended gallbladder and cystic duct stone. Arrow
(←) shows the cystic duct stone.
EUS-GBD was performed via direct puncture with a novel cautery-enhanced, lumen-apposing
metal stent (LAMS) (Hanarostent Z-EUS IT; M.I. Tech, Gyeonggi-do, South Korea) ([Fig. 2]). This is a 12 mm (diameter) × 30 mm (length) fully-covered, lumen-apposing stent
with an inter-flange distance of 22 mm. The opening and deployment of the proximal
and distal flanges of the stent were fully controlled by the endoscopist. The opening
of the distal flange was confirmed on endoscopic ultrasound (EUS) ([Fig. 3]), while the proximal flange was visualized endoluminally ([Fig. 4]). The procedure took 20 minutes and there was good drainage of purulent bile at
the end. Abdominal X-ray confirmed a good stent opening and the presence of the air
cholecystogram ([Fig. 5]). The patient’s fever subsided and her white cell count normalized by day two after
the procedure and she was discharged with a one-week course of oral antibiotics.
Fig. 2 The cautery-enhanced, lumen-apposing metal stent.
Fig. 3 Endoscopic ultrasound image of the distal flange of stent fully deployed. Arrow (→)
shows the distal flange of the stent.
Fig. 4 Endoluminal image of the proximal flange of the fully deployed stent.
Fig. 5 Abdominal X-ray of the stent and air cholecystogram. Arrow (←) shows the lumen-apposing
metal stent; * shows the air cholecystogram.
The availability of a cautery-enhanced, endoscopist-deployed LAMS allows precise stent
placement under EUS guidance to drain the gallbladder into the duodenum. It makes
for safer stent deployment in tight spaces and reduces the need for an experienced
assistant.
Endoscopy_UCTN_Code_TTT_1AS_2AD
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques
in gastroenterological endoscopy. All papers include a high quality video and all
contributions are freely accessible online. Processing charges apply (currently EUR
375), discounts and wavers acc. to HINARI are available.
This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos