CC BY-NC-ND 4.0 · Endoscopy 2022; 54(S 02): E847-E848
DOI: 10.1055/a-1838-3985
E-Videos

Gastrojejunostomy in a patient with previous choledochoduodenostomy and duodenal stent with transcholedocical approach

1   Gastrointestinal Endoscopy Unit – Humanitas Mater Domini – Castellanza, Italy
2   Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
,
Francesco Auriemma
1   Gastrointestinal Endoscopy Unit – Humanitas Mater Domini – Castellanza, Italy
,
1   Gastrointestinal Endoscopy Unit – Humanitas Mater Domini – Castellanza, Italy
,
1   Gastrointestinal Endoscopy Unit – Humanitas Mater Domini – Castellanza, Italy
,
Alessandro Repici
2   Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
3   IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
› Author Affiliations
 

    A 70-year-old woman was admitted to our emergency room due to vomiting for 2 days. The patient had a previous diagnosis of bladder neoplasia with pancreatic head metastasis, and 15 days prior to admission she had undergone placement of a duodenal self-expandable metal stent (SEMS) plus endoscopic ultrasound (EUS)-guided choledochoduodenostomy (CDS) because of jaundice and vomiting due to the compression of the proximal descending duodenum and common bile duct (CBD). A computed tomography scan showed gastric outlet obstruction due to SEMS migration into the third duodenal portion, with the proximal end of the SEMS hitting against the duodenal wall. Because of this complex case we decide to perform an EUS-guided gastrojejunostomy (EUS-GJ) aided by nasobiliary drain (NBD) to target the jejunal loop and avoid puncture of an ileal or colonic loop.

    Following gastric lavage using a gastroscope, an angle-tip guidewire (Jagwire; Boston Scientific, Marlborough, Massachusetts, USA) was advanced through the neoplastic stricture to the jejunal loops, but, despite several attempts, the guidewire could not be passed through the duodenal mesh of the SEMS. Therefore, the guidewire was advanced into the CDS, through the papilla, to the jejunal loops. A 7-Fr NBD was advanced over the wire into the CBD ([Fig. 1]), and the gastroscope was replaced with a linear echoendoscope (GF-UCT180; Olympus, Hamburg, Germany). The target jejunal loop was then irrigated by the NBD using a mixture of contrast medium, methylene blue, and saline solution with the intention of dilating it as much as possible. After exclusion of interposed vessels using color Doppler, EUS-GJ using a lumen-apposing metal stent (Hot-Spaxus 20 × 16 mm; Taewoong Medical Co., Ltd., Goyang-si, Korea) was performed. The EUS-GJ was performed freehand with intrachannel release of the proximal flange ([Video 1]).

    Zoom Image
    Fig. 1 Nasobiliary drainage was used to target the correct jejunal loop inside the choledochoduodenostomy.

    Video 1 Endoscopic ultrasound-guided gastrojejunostomy performed after nasobiliary drain placement inside the common bile duct to overcome the stricture and duodenal stent mesh.


    Quality:

    The patient restarted an oral diet 24 hours after the procedure and was discharged 2 days post-procedure.

    Endoscopy_UCTN_Code_TTT_1AS_2AG

    Endoscopy E-Videos
    https://eref.thieme.de/e-videos

    Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.

    This section has its own submission
    website at
    https://mc.manuscriptcentral.com/e-videos


    #

    Competing interests

    The authors declare that they have no conflict of interest.


    Corresponding author

    Benedetto Mangiavillano, MD
    Gastrointestinal Endoscopy Unit
    Humanitas – Mater Domini
    Via Gerenzano n.2
    21053 Castellanza (VA)
    Italy   

    Publication History

    Article published online:
    25 May 2022

    © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

    Georg Thieme Verlag KG
    Rüdigerstraße 14, 70469 Stuttgart, Germany


    Zoom Image
    Fig. 1 Nasobiliary drainage was used to target the correct jejunal loop inside the choledochoduodenostomy.