Endoscopic ultrasound-guided antegrade dilation using a drill dilator for hepaticojejunostomy stricture with cholangioscopic findings
In obstructive jaundice due to hepaticojejunostomy stricture (HJS), drainage has been performed by endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) [1] [2] [3]. Various techniques have been reported for dilation of the HJS site, including antegrade balloon dilation, self-expandable metal stent deployment, and electrocautery dilation. However, these procedures have the disadvantages of insufficient efficacy, high cost, and risk of bleeding, respectively. A novel drill dilator has recently become available in Japan (Tornus ES; Asahi Intecc, Aichi, Japan) ([Fig. 1]) [4]. This device enables the tract to be easily dilated using a clockwise rotation without using pushing force. We herein describe successful dilation for HJS, with cholangioscopic findings.
An 80-year-old woman who had undergone pancreatoduodenostomy for pancreatic head cancer 1 year previously was admitted to our hospital with obstructive jaundice. Although there was no sign of recurrence of pancreatic cancer, obstructive jaundice due to HJS was observed. We therefore performed EUS-HGS with antegrade dilation at the site of HJS using a balloon catheter, with stent exchange scheduled in 3 months’ time. The endoscopic retrograde cholangiopancreatography (ERCP) catheter was inserted into the biliary tract through the EUS-HGS route, and contrast medium was injected. However, the HJS could not be sufficiently treated ([Fig. 2]) because the ERCP catheter could not be advanced across the HJS site into the intestine ([Fig. 3]). Therefore, we attempted antegrade dilation using the drill dilator, which was successful ([Fig. 4]). The cholangioscope was inserted into the HJS site to check for adverse events following the procedure and confirmed sufficient dilation with no bleeding ([Fig. 5]). Finally, a plastic stent was deployed ([Video 1]).
Video 1 Cholangioscopic findings after antegrade dilation.
Quality:
In conclusion, EUS-guided antegrade dilation for HJS using the drill dilator appears to be effective and safe. Further evaluation is necessary to confirm these findings.
Endoscopy_UCTN_Code_TTT_1AR_2AG
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply, discounts and wavers acc. to HINARI are available.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos
#
Competing interests
The authors declare that they have no conflict of interest.
-
References
- 1 Lee TH, Kim TH, Moon JH. et al. Bilateral versus unilateral placement of metal stents for inoperable high-grade malignant hilar biliary strictures: a multicenter, prospective, randomized study (with video). Gastrointest Endosc 2017; 86: 817-827
- 2 Vienne A, Hobeika E, Gouya H. et al. Prediction of drainage effectiveness during endoscopic stenting of malignant hilar strictures: the role of liver volume assessment. Gastrointest Endosc 2010; 72: 728-735
- 3 Hakuta R, Kogure H, Nakai Y. et al. Unilateral versus bilateral endoscopic nasobiliary drainage and subsequent metal stent placement for unresectable malignant hilar obstruction: A multicenter randomized controlled trial. J Clin Med 2021; 10: 206
- 4 Yasuda T, Hara K, Haba S. Dilation of pancreatic duct stenosis using a newly designed drill dilator. Dig Endosc 2022; 34: e73-e74
Corresponding author
Publication History
Article published online:
09 March 2023
© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Lee TH, Kim TH, Moon JH. et al. Bilateral versus unilateral placement of metal stents for inoperable high-grade malignant hilar biliary strictures: a multicenter, prospective, randomized study (with video). Gastrointest Endosc 2017; 86: 817-827
- 2 Vienne A, Hobeika E, Gouya H. et al. Prediction of drainage effectiveness during endoscopic stenting of malignant hilar strictures: the role of liver volume assessment. Gastrointest Endosc 2010; 72: 728-735
- 3 Hakuta R, Kogure H, Nakai Y. et al. Unilateral versus bilateral endoscopic nasobiliary drainage and subsequent metal stent placement for unresectable malignant hilar obstruction: A multicenter randomized controlled trial. J Clin Med 2021; 10: 206
- 4 Yasuda T, Hara K, Haba S. Dilation of pancreatic duct stenosis using a newly designed drill dilator. Dig Endosc 2022; 34: e73-e74