Handchir Mikrochir Plast Chir 2024; 56(04): 321-326
DOI: 10.1055/a-2246-2190
Fallbericht

Sequenzieller chimärer Beckenkamm-SIEA-Lappen zur Rekonstruktion eines osteokutanen Defektes des Unterschenkels und die Wichtigkeit zur Schonung des Ramus Ascendens – ein Fallbericht

Sequential Chimeric Osteocutaneous DCIA-Perforator-SIEA Flap to Reconstruct an Osteocutaneous Defect in the Lower Extremity and the Importance of Preserving the Ascending Branch – A Case Report
1   Abteilung für Plastische, Ästhetische und Rekonstruktive Chirurgie; Paracelsus Medizinische Privatuniversität, Krankenhaus der Barmherzigen Brüder Salzburg, Salzburg, Austria
,
Elisabeth Russe
1   Abteilung für Plastische, Ästhetische und Rekonstruktive Chirurgie; Paracelsus Medizinische Privatuniversität, Krankenhaus der Barmherzigen Brüder Salzburg, Salzburg, Austria
,
Georg Eder
2   Abteilung für Unfallchirurgie und Sporttraumatologie, Kardinal Schwarzenberg’sches Krankenhaus, Schwarzach, Austria
,
Karl Schwaiger
1   Abteilung für Plastische, Ästhetische und Rekonstruktive Chirurgie; Paracelsus Medizinische Privatuniversität, Krankenhaus der Barmherzigen Brüder Salzburg, Salzburg, Austria
,
Julia Maria Puchner
1   Abteilung für Plastische, Ästhetische und Rekonstruktive Chirurgie; Paracelsus Medizinische Privatuniversität, Krankenhaus der Barmherzigen Brüder Salzburg, Salzburg, Austria
,
Gottfried Wechselberger
1   Abteilung für Plastische, Ästhetische und Rekonstruktive Chirurgie; Paracelsus Medizinische Privatuniversität, Krankenhaus der Barmherzigen Brüder Salzburg, Salzburg, Austria
› Author Affiliations

Zusammenfassung

Hintergrund Eine etablierte Möglichkeit zur simultanen Rekonstruktion von Knochen- und Weichteildefekten stellt der frei vaskularisierte osteokutane Beckenkammspanlappen mit Hautinsel dar, der durch die Arteria und Vena circumflexa ilium profunda genährt wird. Die Ausprägung dieser kutanen Perforatoren ist jedoch nicht konstant. Ein alternative Rekonstruktionstechnik bei fehlenden Hautperforatoren stellt die Verwendung der sequenziell chimären Lappenplastik dar mit dem Ramus ascendens als ausschlaggebendem Anschlussgefäß.

Patient und Methode Ein 58-jähriger Mann zog sich bei einem Lawinenverschüttungstrauma eine offene Tibiafraktur mit ausgedehntem Weichteil- und Knochendefekt zu. Wir rekonstruierten diesen osteokutanen Defekt mittels sequenziellem chimären Beckenkamm-SIEA-Lappen.

Ergebnisse Die Schonung des Ramus ascendens der Arteria und Vena circumflexa ilium profunda ermöglichte uns die Durchführung eines sequenziell chimären Beckenkamm-SIEA-Lappens.Dieser osteokutane sequenzielle chimäre Beckenkamm-SIEA-Lappen heilte komplikationslos ein. Bei unserem Patienten entwickelte sich im Bereich der Entnahmestelle eine Hernie, die nach chirurgischer Behandlung ohne weitere Auffälligkeiten abheilte. Der Patient erlangte eine zufriedenstellende Funktion des linken Unterschenkels und kann erneut alltäglichen und sportlichen Tätigkeiten nachgehen.

Schlussfolgerung Auf die Schonung des Ramus ascendens sowie die Gefäße zur Hebung entweder eines konsekutiven SIEA- oder SCIP-Lappens ist bei der Präparation des osteokutanen Beckenkammtransplantates zu achten.

Abstract

Background The deep circumflex iliac artery (DCIA) perforator flap is an established method to reconstruct osteocutaneous defects. However, the cutaneous perforators come with a great anatomic variability. To deal with this problem, we used a sequential chimeric osteocutaneous free flap for reconstruction.

Patients and Methods A 58-year-old man presented with an open tibial fracture after an avalanche accident resulting in an extended osteocutaneous defect in the lower extremity. The injury required osteocutaneous free flap coverage. We reconstructed the defect with a sequential chimeric osteocutaneous DCIA-perforator-SIEA flap.

Results The preservation of the ascending branch of the deep circumflex iliac vessels offered us the possibility to effectively cover an extended osteocutaneous defect in the lower extremity with a sequential chimeric osteocutaneous DCIA-perforator-SIEA flap. In our patient, the sequential chimeric osteocutaneous DCIA-perforator-SIEA flap healed without complications. A small hernia developed at the inguinal donor site area, but it healed without further complications after surgical treatment. The patient regained an adequate function and returned to daily life and physical exercise.

Conclusion While preparing the DCIA-perforator free flap, it is important to preserve the ascending branch of the deep circumflex iliac vessels and the vessels needed to harvest either a SIEA or SCIP flap.



Publication History

Received: 16 September 2023

Accepted: 03 January 2024

Article published online:
15 February 2024

© 2024. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • Literatur

  • 1 Taylor GI, Townsend P, Corlett R. Superiority of the deep circumflex iliac vessels as the supply for free groin flaps. Plast Reconstr Surg 1979; 64: 595-604
  • 2 Sauerbier M, Maldonado AA, Hoffmann R. et al. Possible applications of free microsurgical fibula transplantation in the reconstruction of complex bone defects in the extremities: review of the literature and case series. Handchir Mikrochir Plast Chir Organ Deutschsprachigen Arbeitsgemeinschaft Handchir Organ Deutschsprachigen Arbeitsgemeinschaft Mikrochir Peripher Nerven Gefasse Organ V 2020; 52: 505-517
  • 3 Sekiguchi J, Kobayashi S, Ohmori K. Use of the Osteocutaneous Free Scapular Flap on the Lower Extremities. Plast Reconstr Surg 1993; 91: 103-112
  • 4 Kastenberger T, Kaiser P, Bode S. et al. Treatment of scaphoid non-union: vascularised iliac crest graft or medial femur condyle graft?. Handchir Mikrochir Plast Chir Organ Deutschsprachigen Arbeitsgemeinschaft Handchir Organ Deutschsprachigen Arbeitsgemeinschaft Mikrochir Peripher Nerven Gefasse Organ V 2020; 52: 419-424
  • 5 Kaiser B, Gohritz A, Mende K. et al. Bone Reconstruction in the Upper Extremity other than the Scaphoid with the free vascularized Medial Femoral Condyle. Handchir Mikrochir Plast Chir Organ Deutschsprachigen Arbeitsgemeinschaft Handchir Organ Deutschsprachigen Arbeitsgemeinschaft Mikrochir Peripher Nerven Gefasse Organ V 2023; 55: 53-59
  • 6 Auleda J, Bianchi A, Tibau R. et al. Hernia through iliac crest defects: A report of four cases. Int Orthop 1995; 19
  • 7 Prabhu R, Kumar N, Shenoy R. Iliac crest bone graft donor site hernia: not so uncommon. Case Rep 2013; 2013: bcr2013010386-bcr2013010386
  • 8 Ting JWC, Rozen WM, Grinsell D. et al. The in vivo anatomy of the deep circumflex iliac artery perforators: defining the role for the DCIA perforator flap. Microsurgery 2009; 29: 326-329
  • 9 Koshima I, Nanba Y, Tsutsui T. et al. Sequential vascularized iliac bone graft and a superficial circumflex iliac artery perforator flap with a single source vessel for established mandibular defects. Plast Reconstr Surg 2004; 113: 101-106
  • 10 Matsumoto T, Tsumura T, Kishimoto K. et al. Sequential chimeric free deep circumflex iliac artery bone flap and superficial circumflex iliac artery perforator flap from the same site for one-stage reconstructions of severe hand injury: A report of two cases. JPRAS Open 2020; 26: 49-53
  • 11 Kim H-S, Kim BC, Kim H-J. et al. Anatomical basis of the deep circumflex iliac artery flap. J Craniofac Surg 2013; 24: 605-609