Over-the-scope clip on over-the-scope clip technique for closure of delayed perforation near a previously placed over-the-scope clip
The over-the-scope (OTS) clip is effective for defect closure during endoscopic treatment [1] [2]. OTS clip closure has been reported to be effective in preventing delayed perforation and bleeding, especially after duodenal endoscopic resection [3]. However, adverse events associated with the OTS clip itself have been reported, including bleeding, perforation, infection, and failure to attach [4] [5].
The patient was a 50-year-old man who underwent endoscopic submucosal dissection (ESD) for an 80 mm, 0-IIa, superficial, nonampullary, epithelial tumor in the descending duodenum. After endoscopic treatment, the ulcer was closed with OTS clips ([Fig. 1]). Fever and abdominal pain persisted after endoscopic treatment, and contrast-enhanced computed tomography scan of the abdomen on the third day after endoscopic treatment showed free air and abscess formation around the outside of the resection site ([Fig. 2] a). Emergency upper gastrointestinal endoscopy was performed because of delayed perforation. We tried to close the perforation, but the fragile edges of the perforation made it difficult to close with conventional hemostatic clips. Then, we pulled the edge of the perforation site and the tissue grasped by the previous OTS clip together, and secured them with a new OTS clip ([Fig. 3], [Video 1]).






Qualität:
Endoscopy 14 days after ESD confirmed closure of the perforation ([Fig. 4]). Endoscopy 37 days after closure of the perforation confirmed maintenance of the closure and revealed that the abscess had disappeared ([Fig. 2] b); the patient was then discharged. Pathological findings showed curative resection with adenocarcinoma, pTis (depth M), Ly0, V0, pVM0, pHM0 ([Fig. 5]).




OTS clips have a strong grasping force but are difficult to remove once implanted. Using strong grasping force, we tried to pull together the edge of the perforation site and the tissue grasped by the previous OTS clip. Finally, the perforation site, including the previous OTS clip, was completely covered by the second OTS clip.
Endoscopy_UCTN_Code_CPL_1AH_2AZ_3AD
E-Videos is an open access online section of the journal Endoscopy, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/).
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos.
#
Conflict of Interest
The authors declare that they have no conflict of interest.
Acknowledgement
We wish to express our deep appreciation to all endoscopy medical staff for their assistance with endoscopic procedures.
-
References
- 1 Kato M, Takeuchi Y, Hoteya S. et al. Outcomes of endoscopic resection for superficial duodenal tumors: 10 years’ experience in 18 Japanese high-volume centers. Endoscopy 2022; 54: 663-670
- 2 Ohata K, Sakai E, Suzuki Y. et al. Risk factors of delayed bleeding after endoscopic resection of superficial non-ampullary duodenal epithelial tumors and prevention by over-the-scope and conventional clipping. Dig Endosc 2021; 33: 390-398
- 3 Bartell N, Bittner K, Kaul V. et al. Clinical efficacy of the over-the-scope clip device: a systematic review. World J Gastroenterol 2020; 26: 3495-3516
- 4 El Bacha H, Prat F. Endoscopic management of iatrogenic EUS-related duodenal perforations with over-the-scope clips. Endosc Int Open 2020; 8: E59-E63
- 5 Gazelakis K, Lovett G, Chen R. et al. Over-the-scope clip for the immediate management of Stapfer type-1 duodenal perforation during endoscopic retrograde cholangiopancreatography. Case Rep Gastroenterol 2022; 16: 186-194
Correspondence
Publikationsverlauf
Artikel online veröffentlicht:
31. Januar 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).
Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
-
References
- 1 Kato M, Takeuchi Y, Hoteya S. et al. Outcomes of endoscopic resection for superficial duodenal tumors: 10 years’ experience in 18 Japanese high-volume centers. Endoscopy 2022; 54: 663-670
- 2 Ohata K, Sakai E, Suzuki Y. et al. Risk factors of delayed bleeding after endoscopic resection of superficial non-ampullary duodenal epithelial tumors and prevention by over-the-scope and conventional clipping. Dig Endosc 2021; 33: 390-398
- 3 Bartell N, Bittner K, Kaul V. et al. Clinical efficacy of the over-the-scope clip device: a systematic review. World J Gastroenterol 2020; 26: 3495-3516
- 4 El Bacha H, Prat F. Endoscopic management of iatrogenic EUS-related duodenal perforations with over-the-scope clips. Endosc Int Open 2020; 8: E59-E63
- 5 Gazelakis K, Lovett G, Chen R. et al. Over-the-scope clip for the immediate management of Stapfer type-1 duodenal perforation during endoscopic retrograde cholangiopancreatography. Case Rep Gastroenterol 2022; 16: 186-194