Endoscopy 2009; 41: E21-E22
DOI: 10.1055/s-0028-1103468
Unusual cases and technical notes

© Georg Thieme Verlag KG Stuttgart · New York

EUS-guided drainage of ruptured liver abscess

T.  L.  Ang1 , S.  Seewald2 , E.  K.  Teo1 , K.  M.  Fock1 , N.  Soehendra2
  • 1Division of Gastroenterology, Department of Medicine, Changi General Hospital, Singapore
  • 2Department of Interdisciplinary Endoscopy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
Further Information

T. L. Ang

Division of Gastroenterology
Changi General Hospital

2 Simei St 3
Singapore 529889

Fax: +65-6781-6202

Email: tiing_leong_ang@cgh.com.sg

Publication History

Publication Date:
13 February 2009 (online)

Table of Contents

Liver abscesses are usually drained percutaneously. If drainage is inadequate, surgery may be necessary [1]. Endoscopic ultrasound (EUS)-guided drainage of pancreatic, pelvic, subphrenic, and splenic abscesses has been reported [2]. There has been one reported case of EUS-guided drainage of a well-encapsulated liver abscess [3]. A ruptured liver abscess is usually an indication for surgery [1]. We report a case of ruptured liver abscess with a walled-off left subhepatic collection that was successfully treated by EUS-guided drainage using a double-wire technique [4] that facilitated the placement of multiple stents.

A 58-year-old woman presented with a 1-week history of fever and lethargy. There was fullness in the left upper abdomen but no peritonism. The woman was also in diabetic ketoacidosis. Computer tomography showed a ruptured left liver abscess communicating with a walled-off subhepatic collection measuring 10.7 × 5.7 cm ([Fig. 1]). The patient was treated with intravenous antibiotics and insulin. Percutaneous drainage was attempted but was unsuccessful, with minimal aspirate. The surgical risks were considered high, so the patient was referred for endoscopic drainage. The subhepatic abscess was visualized using a therapeutic linear echoendoscope (GF-UCT160; Olympus, Tokyo, Japan) and punctured with a 19-gauge needle (EUSN-19-T; Cook Endoscopy, Winston-Salem, North Carolina, USA) ([Fig. 2]) via a transgastric approach. A 480-cm, 0.035-inch guide wire was inserted and the puncture needle was withdrawn. A 10-Fr Soehendra biliary dilator (Cook Endoscopy) was inserted over the guide wire and a second 0.035-inch guide wire was inserted through the dilator. The dilator was withdrawn, leaving two guide wires within the abscess cavity [4] ([Fig. 3]). Balloon dilation of the puncture site to 8 mm was performed (CRE; Boston Scientific, Natick, Massachusetts, USA). An 8-Fr and a 10-Fr 7-cm double pigtail stent were sequentially inserted ([Figs. 4], [5]). The procedure was completed within 30 minutes without complications. Resolution of the liver abscess and subhepatic collection was documented after 11 days and both stents were removed.

Zoom Image

Fig. 1 Computer tomography image of the ruptured liver abscess showing communication with a walled-off subhepatic collection.

Zoom Image

Fig. 2 Endoscopic ultrasound-guided puncture of the subhepatic abscess collection.

Zoom Image

Fig. 3 Fluoroscopy showing two guide wires inserted through a 10-Fr Soehendra dilator within the abscess cavity. The outline of a previously inserted percutaneous drainage catheter within the liver abscess can be seen; this catheter had minimal aspirate.

Zoom Image

Fig. 4 Pus flowed out of the abscess cavity after placement of a single stent, obscuring the endoscopic view. The presence of another guide wire facilitated the placement of a second stent despite the poor endoscopic view.

Zoom Image

Fig. 5 Two transgastric stents were inserted for drainage of the abscess.

Endoscopy_UCTN_Code_TTT_1AS_2AG

#

References

  • 1 Chung Y F, Tan Y M, Lui H F. et al . Management of pyogenic liver abscesses – percutaneous or open drainage?.  Singapore Med J. 2007;  48 1158-1165
  • 2 Seewald S, Ang T L, Teng K YK. et al . Innovation forum: EUS guided drainage of abdominal abscesses.  Endoscopy. 2008;  (in press)
  • 3 Seewald S, Imazu H, Omar S. et al . EUS-guided drainage of hepatic abscess.  Gastrointest Endosc. 2005;  61 495-498
  • 4 Ang T L, Teo E K, Fock K M. EUS-guided drainage of infected pancreatic pseudocyst: use of a 10Fr Soehendra dilator to facilitate a double-wire technique for initial transgastric access (with videos).  Gastrointest Endosc. 2008;  68 192-194

T. L. Ang

Division of Gastroenterology
Changi General Hospital

2 Simei St 3
Singapore 529889

Fax: +65-6781-6202

Email: tiing_leong_ang@cgh.com.sg

#

References

  • 1 Chung Y F, Tan Y M, Lui H F. et al . Management of pyogenic liver abscesses – percutaneous or open drainage?.  Singapore Med J. 2007;  48 1158-1165
  • 2 Seewald S, Ang T L, Teng K YK. et al . Innovation forum: EUS guided drainage of abdominal abscesses.  Endoscopy. 2008;  (in press)
  • 3 Seewald S, Imazu H, Omar S. et al . EUS-guided drainage of hepatic abscess.  Gastrointest Endosc. 2005;  61 495-498
  • 4 Ang T L, Teo E K, Fock K M. EUS-guided drainage of infected pancreatic pseudocyst: use of a 10Fr Soehendra dilator to facilitate a double-wire technique for initial transgastric access (with videos).  Gastrointest Endosc. 2008;  68 192-194

T. L. Ang

Division of Gastroenterology
Changi General Hospital

2 Simei St 3
Singapore 529889

Fax: +65-6781-6202

Email: tiing_leong_ang@cgh.com.sg

Zoom Image

Fig. 1 Computer tomography image of the ruptured liver abscess showing communication with a walled-off subhepatic collection.

Zoom Image

Fig. 2 Endoscopic ultrasound-guided puncture of the subhepatic abscess collection.

Zoom Image

Fig. 3 Fluoroscopy showing two guide wires inserted through a 10-Fr Soehendra dilator within the abscess cavity. The outline of a previously inserted percutaneous drainage catheter within the liver abscess can be seen; this catheter had minimal aspirate.

Zoom Image

Fig. 4 Pus flowed out of the abscess cavity after placement of a single stent, obscuring the endoscopic view. The presence of another guide wire facilitated the placement of a second stent despite the poor endoscopic view.

Zoom Image

Fig. 5 Two transgastric stents were inserted for drainage of the abscess.