Laryngorhinootologie 2010; 89(4): 200-202
DOI: 10.1055/s-0030-1253308
Tipps & Tricks

© Georg Thieme Verlag KG Stuttgart ˙ New York

Technik zur Platzierung von Jones Tubes im Rahmen der Tränenwegschirurgie

Technique for Jones Tube Placement in Lacimal Drainage Surgery
Further Information

Publication History

Publication Date:
12 April 2010 (online)

 

Abstract

In certain cases, the use of a Jones Tube is necessary for lacrimal duct reconstruction. Although the principle is straight forward, the practical procedure can prove to be difficult. The procedure requires the resection of the medial bony wall of the lacrimal sac. We form a duct between the medial canthus and the nasal cavity using a 14 gauge canula. By removing the needle, the catheter remains in place and serves as a guide for the placement of the Jones Tube with the assistance of an obturator. Thus the duct is not lost and an additional puncture is unnecessary.