Subscribe to RSS
DOI: 10.1055/s-0030-1255897
© Georg Thieme Verlag KG Stuttgart · New York
Small-bowel perforation in a patient with Roux-en-Y anatomy for Peutz–Jeghers polyps after spiral enteroscopic investigation
Z.-Z. GeMD
Department of Gastroenterology
Shanghai Renji
Hospital
Shanghai Jiaotong University School of
Medicine
Shanghai Institute of Digestive Disease
145 Shan-dong zhong Rd
Shanghai
200001
China
Fax: +86-21-68383015
Email: zhizhengge@yahoo.com.cn
Publication History
Publication Date:
18 March 2011 (online)
Spiral enteroscopy is a new technique for diagnosis and treatment of small-bowel disease. In July 2009, a 19-year-old woman with Peutz–Jeghers syndrome was sent to our hospital for screening and treatment. The patient had undergone segmental resection of the distal jejunum, 4 years previously, for acute intestinal obstruction due to large Peutz–Jeghers polyps.
After informed consent had been obtained, we chose antegrade spiral enteroscopy for small-bowel investigation. The procedure was performed under monitored anesthesia. A standard Fujinon EN-450P5 enteroscope with an Endo-Ease Discovery SB overtube was used. The insertion depth of the enteroscope was about 220 cm beyond the ligament of Treitz. The duration of the procedure was 44 min.
During the investigation, a normal Roux-en-Y anastomotic stoma was found at about 200 cm beyond the ligament of Treitz ([Fig. 1]), and eight IIa-type hyperplastic polyps of size 3 – 8 mm were found nearby. Argon plasma coagulation (APC) was used for treatment of these polyps.
The procedure of investigation and treatment was successful, and no bleeding occurred. However, the patient experienced severe abdominal pain after 2 h. The abdominal computed tomography (CT) scan showed pneumoperitoneum. During emergent surgery, a perforation of 15 mm was seen at the anastomotic stoma, and intraperitoneal adhesion was severe. The patient was clinically stable after repair of the perforation, and was discharged 5 days later.
Diagnostic double-balloon enteroscopy (DBE) has an overall complication rate of 1.7 % (perforation 0.3 %, pancreatitis 0.3 %, bleeding 0.8 %). Therapeutic DBE has a relatively high complication rate of 4.3 % (APC perforation 1.2 %, dilation perforation 2.9 %) [1]. In patients with small-bowel anastomoses, perforations occur easily during diagnostic DBE procedures [2]. The rate of perforation after spiral enteroscopy is reported to be 0.34 % [3]. Spiral enteroscopy has been successfully performed in patients with surgically altered anatomies [4], with no reports of perforation until now. In this case, perforation was found to have occurred because of prior surgery not therapeutic procedures. Avoiding excessive tension may help to limit complications including perforation.
Endoscopy_UCTN_Code_CPL_1AI_2AD
Competing interests: None
#References
- 1 Mensink P B, Haringsma J, Kucharzik T et al. Complications of double balloon enteroscopy: a multicenter survey. Endoscopy . 2007; 39 613-615
- 2 Semrad C E. Small-bowel enteroscopy: territory conquered, future horizons. Curr Opin Gastroenterol . 2009; 25 110-115
- 3 Akerman P A, Cantero D. Severe complications of spiral enteroscopy in the first 1750 patients. Gastrointest Endosc. 2009; 69 AB127
- 4 Akerman P A, Agrawal D, Chen W et al. Spiral enteroscopy: a novel method of enteroscopy by using the Endo-Ease Discovery SB overtube and a pediatric colonoscope. Gastrointest Endosc. 2009; 69 327-332
Z.-Z. GeMD
Department of Gastroenterology
Shanghai Renji
Hospital
Shanghai Jiaotong University School of
Medicine
Shanghai Institute of Digestive Disease
145 Shan-dong zhong Rd
Shanghai
200001
China
Fax: +86-21-68383015
Email: zhizhengge@yahoo.com.cn
References
- 1 Mensink P B, Haringsma J, Kucharzik T et al. Complications of double balloon enteroscopy: a multicenter survey. Endoscopy . 2007; 39 613-615
- 2 Semrad C E. Small-bowel enteroscopy: territory conquered, future horizons. Curr Opin Gastroenterol . 2009; 25 110-115
- 3 Akerman P A, Cantero D. Severe complications of spiral enteroscopy in the first 1750 patients. Gastrointest Endosc. 2009; 69 AB127
- 4 Akerman P A, Agrawal D, Chen W et al. Spiral enteroscopy: a novel method of enteroscopy by using the Endo-Ease Discovery SB overtube and a pediatric colonoscope. Gastrointest Endosc. 2009; 69 327-332