Subscribe to RSS
DOI: 10.1055/s-0030-1256058
© Georg Thieme Verlag KG Stuttgart · New York
Closure of a gastrotracheal fistula using a cardiac septal occluder device
Y. C. LeeMD, PhD
Department of Internal Medicine
Yonsei University
College of Medicine
250 Seongsanno
Seodaemun-gu
Seoul
120-752
Korea
Fax: +82-2-3936884
Email: leeyc@yuhs.ac
Publication History
Publication Date:
01 February 2011 (online)
Anastomotic leak is one of the most serious complications after esophagectomy, and it occurs in 5 % – 29 % of patients [1]. Although there are no standardized methods for treating intrathoracic leakage, the treatment options include surgery, external drainage, and endoscopic treatment.
A 68-year-old man was hospitalized with a mild cough associated with oral intake. He had been diagnosed with squamous cell carcinoma of the esophagus 18 months earlier and underwent esophagectomy and gastric pull-up surgery. A chest computed tomography (CT) scan revealed a fistula between the left main bronchus and the neoesophagus ([Fig. 1]).
Treatment was attempted with an endoscopic clip, fibrin glue, and a clip with detachable snare, but the fistula remained open. Finally, the patient agreed to a treatment option using an Amplatzer Multi-Fenestrated “Cribriform” Septal Occluder (AGA Medical Corporation, Plymouth, Minnesota, USA). A guide wire was inserted into the esophagus, and we advanced an occluder over the wire. Once the proper position was confirmed, an interventional cardiologist released the device, first on the tracheal side and then on the gastric side ([Fig. 2]).
A barium study on day 5 showed complete fistula closure ([Fig. 3]), and an oral diet was tolerated.
At the 1-month follow-up, endoscopic evaluation confirmed stable fistula closure by the occluder.
Over the past decade, management of anastomotic leaks has shifted toward a more conservative approach, including the use of endoscopic clips, fibrin glue [2], and self-expanding stents [3]. However, in the present case, previously reported techniques failed to close the fistula. We therefore attempted an experimental approach using the atrial septal defect occluder. In our review of the literature, there are only two prior reports in which Amplatzer devices were used to close esophagotracheal and bronchoesophageal fistulas [4] [5]. Although further studies are needed to establish the efficacy, the Amplatzer device could be considered in selected patients with anastomotic leakage.
Endoscopy_UCTN_Code_TTT_1AO_2AI
Competing interests: None
#References
- 1 Urschel J D. Esophagogastrostomy anastomotic leaks complicating esophagectomy: a review. Am J Surg. 1995; 169 634-640
- 2 Bohm G, Mossdorf A, Klink C et al. Treatment algorithm for postoperative upper gastrointestinal fistulas and leaks using combined vicryl plug and fibrin glue. Endoscopy. 2010; 42 599-602
- 3 Schubert D, Scheidbach H, Kuhn R et al. Endoscopic treatment of thoracic esophageal anastomotic leaks by using silicone-covered, self-expanding polyester stents. Gastrointest Endosc. 2005; 61 891-896
- 4 Repici A, Presbitero P, Carlino A et al. First human case of esophagus-tracheal fistula closure by using a cardiac septal occluder (with video). Gastrointest Endosc. 2010; 71 867-869
- 5 Green D A, Moskowitz W B, Shepherd R W. Closure of a broncho-to-neoesophageal fistula using an Amplatzer septal occluder device. Ann Thorac Surg. 2010; 89 2010-2012
Y. C. LeeMD, PhD
Department of Internal Medicine
Yonsei University
College of Medicine
250 Seongsanno
Seodaemun-gu
Seoul
120-752
Korea
Fax: +82-2-3936884
Email: leeyc@yuhs.ac
References
- 1 Urschel J D. Esophagogastrostomy anastomotic leaks complicating esophagectomy: a review. Am J Surg. 1995; 169 634-640
- 2 Bohm G, Mossdorf A, Klink C et al. Treatment algorithm for postoperative upper gastrointestinal fistulas and leaks using combined vicryl plug and fibrin glue. Endoscopy. 2010; 42 599-602
- 3 Schubert D, Scheidbach H, Kuhn R et al. Endoscopic treatment of thoracic esophageal anastomotic leaks by using silicone-covered, self-expanding polyester stents. Gastrointest Endosc. 2005; 61 891-896
- 4 Repici A, Presbitero P, Carlino A et al. First human case of esophagus-tracheal fistula closure by using a cardiac septal occluder (with video). Gastrointest Endosc. 2010; 71 867-869
- 5 Green D A, Moskowitz W B, Shepherd R W. Closure of a broncho-to-neoesophageal fistula using an Amplatzer septal occluder device. Ann Thorac Surg. 2010; 89 2010-2012