Pneumologie 2012; 66(10): 607-609
DOI: 10.1055/s-0032-1325684
Case Report
© Georg Thieme Verlag KG Stuttgart · New York

Tracheal Perforation by an Oesophageal Stent

Tracheaperforation durch einen Ösophagusstent
H. Knoop
1   Thoraxzentrum Ruhrgebiet, Klinik für Pneumologie und Infektiologie, EVK Herne – Betriebsstelle Eickel (Prof. Dr. med. S. Ewig)
,
U. Knoop
2   Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil, Medizinische Klinik III – Pneumologie, Allergologie, Schlaf- und Beatmungsmedizin (Prof. Dr. med. J. Behr)
,
H.-C.-D. Martini
3   Radiologie Witten (Dr. med. H.-C.-D. Martini)
,
L. Heining
1   Thoraxzentrum Ruhrgebiet, Klinik für Pneumologie und Infektiologie, EVK Herne – Betriebsstelle Eickel (Prof. Dr. med. S. Ewig)
,
R. Wolf
1   Thoraxzentrum Ruhrgebiet, Klinik für Pneumologie und Infektiologie, EVK Herne – Betriebsstelle Eickel (Prof. Dr. med. S. Ewig)
,
S. Ewig
1   Thoraxzentrum Ruhrgebiet, Klinik für Pneumologie und Infektiologie, EVK Herne – Betriebsstelle Eickel (Prof. Dr. med. S. Ewig)
,
E. Hecker
4   Thoraxzentrum Ruhrgebiet, Klinik für Thoraxchirurgie, EVK Herne – Betriebsstelle Eickel (Dr. med. Dipl.-Oec. E. Hecker)
› Institutsangaben
Weitere Informationen

Corresponding author

Dr. med. Heiko Knoop
Thoraxzentrum Ruhrgebiet
Klinik für Pneumologie und Infektiologie
Evangelisches Krankenhaus Herne – Betriebsstelle Eickel
Akademisches Lehrkrankenhaus der Universität Duisburg-Essen
Hordeler Str. 7 – 9
44651 Herne

Publikationsverlauf

received 20. August 2012

accepted 23. August 2012

Publikationsdatum:
10. Oktober 2012 (online)

 

Abstract

In a 63 year-old female patient with oesophageal carcinoma a tracheal perforation by an oesophageal stent was diagnosed. A first attempt of tracheal stenting was not successful due to spontaneous dislocation of the stent. Therefore, a shorter stent was chosen and correctly placed in a second session. This case report on an oesophagotracheal fistula provides a summary of this complication in advanced oesophageal cancer.


Zusammenfassung

Bei einer 63-jährigen Patientin mit Ösophaguskarzinom wurde eine Tracheaperforation durch einen Ösophagusstent diagnostiziert. Ein erster Versuch der Versorgung mit einem Trachealstent erwies sich aufgrund einer spontanen Dislokation des Stents als nicht erfolgreich. Aus diesem Grund wurde im Rahmen einer erneuten starren Bronchoskopie ein kürzerer Stent platziert mit anhaltend korrekter Lage. Dieser Fallbericht über eine ösophagotracheale Fistel gibt eine kurze Übersicht über diese Komplikation bei Patienten mit fortgeschrittenem Ösophaguskarzinom.


Case report

A 63 year-old female patient was transferred to our hospital for further evaluation of an unusual tracheal lesion. In November 2011, an advanced ulcerating low differentiated keratinizing squamous cell carcinoma (SCC) of the oesophagus had been diagnosed. Palliative chemotherapy and radiotherapy had been performed in the past but had to be stopped later on due to progressive disease and deterioration in ECOG (Eastern Cooperative Oncology Group) Performance Status [1]. In February 2012, endoscopic dilation and implantation of an oesophageal stent was necessary due to stenosis. Since the beginning of July 2012, the patient suffered from hoarseness and progressive cough without expectoration and therefore was admitted to the hospital where the oesophageal carcinoma (EC) was first diagnosed and treated. Computed tomography ([Fig. 1 a – c]) and bronchoscopy were performed before transfer to our hospital.

Zoom
Fig. 1 Oesophago-tracheal fistula of 3.6 cm length after oesophageal stenting with high grade tracheal stenosis.

On first inspection with flexible bronchoscopy a long segmental penetration of the oesophageal stent into the trachea was obvious, covering the complete tracheal width and a length of 3.6 cm ([Fig. 2]). The distance to the main carina was 3 cm and to the vocal cord-planar approximately 4 cm. The penetration caused a slot-shaped high grade stenosis of the trachea which could be passed easily with the bronchoscope. Additionally, the mucosa of the middle lobe was swollen with consecutive concentric constriction of the middle lobe ostium. Histological analysis of the mucosal biopsy revealed SCC with adenocarcinoma components according to a pulmonary metastasis of the EC. Implantation of a tracheal stent (80 mm × 20 mm) via rigid bronchoscopy was performed and seemed to be successful with correct bronchoscopic localization of the stent. However, the patient developed severe hypoxemia shortly after the procedure. X-ray suggested a dislocation of the stent ([Fig. 3 a]) which had to be retracted immediately. In a second session a covered expandable nitinol stent (60 × 20 mm, nickel-titanium alloy, Micro-Tech Europe) was implanted successfully ([Fig. 3 b]) with a distance to both main carina and vocal cord planar of 1 cm, respectively ([Fig. 4 a, b]). Flexible bronchoscopy confirmed the correct localization of the stent one day after implantation. The patient could be re-transferred for further palliative treatment.

Zoom
Fig. 2 Oesophageal stent penetrating the trachea through the dorsal tracheal wall and causing high grade stenosis in bronchoscopy.
Zoom
Fig. 3a Infiltrative lesion in the left upper pulmonary lobe highly suggestive for dislocation of the tracheal stent, b Correct localization of the oesophageal stent in X-ray. Due to reduced performance status, a standing lateral radiograph to visualize the correct position of the tracheal stent was not possible.
Zoom
Fig. 4 Tracheal stent with a distance to both main carina and vocal cord planar of 1 cm, respectively, in bronchoscopy.

Discussion

EC is the sixth most common cause among cancer related deaths [2]. Risk factors for EC identified so far include alcohol abuse [3], chewing tobacco [2] and low consumption of fruit and vegetable [4]. Diagnosis, treatment and follow-up should be performed according to current guidelines [5] [6]. Advanced EC may erode into adjacent structures and hereby cause esophagorespiratory fistulas (ERF). This complication with relevant impact on prognosis occurs in less than 20 % of patients with EC [7]. The main fistula site is the trachea [8]. Several fistulas may occur in the same patient [9]. Computertomography and bronchoscopy are the main diagnostic tools for further evaluation. In patients with EC and good performance status, surgery remains a treatment option for ERF. Besides surgical treatment, stenting of oesophagus, airway or both is an efficient palliative therapeutic alternative which can relieve symptoms and may improve survival [10, 11]. Symptoms can be mainly attributed to pulmonary infections due to recurrent aspiration.

Tracheal perforation has been a common complication in 15 to 40 % of patients after oesophageal stenting with conventional unexpandable plastic prostheses which was the treatment of choice for ERF until the early 1990s [12]. Nowadays, the use of covered expandable metallic stents has been established as these stents show less procedural complications [13]. However, perforation of the trachea by this type of oesophageal stents has also been described [14].



Conflict of interest

The authors have no conflict of interest.

Acknowledgements

The authors thank the “Radiologie Herne” (Dr. med. T. Magin) for the permission to use the X-rays.


Corresponding author

Dr. med. Heiko Knoop
Thoraxzentrum Ruhrgebiet
Klinik für Pneumologie und Infektiologie
Evangelisches Krankenhaus Herne – Betriebsstelle Eickel
Akademisches Lehrkrankenhaus der Universität Duisburg-Essen
Hordeler Str. 7 – 9
44651 Herne


Zoom
Fig. 1 Oesophago-tracheal fistula of 3.6 cm length after oesophageal stenting with high grade tracheal stenosis.
Zoom
Fig. 2 Oesophageal stent penetrating the trachea through the dorsal tracheal wall and causing high grade stenosis in bronchoscopy.
Zoom
Fig. 3a Infiltrative lesion in the left upper pulmonary lobe highly suggestive for dislocation of the tracheal stent, b Correct localization of the oesophageal stent in X-ray. Due to reduced performance status, a standing lateral radiograph to visualize the correct position of the tracheal stent was not possible.
Zoom
Fig. 4 Tracheal stent with a distance to both main carina and vocal cord planar of 1 cm, respectively, in bronchoscopy.