Endoscopy 2014; 46(S 01): E60
DOI: 10.1055/s-0033-1359162
Cases and Techniques Library (CTL)
© Georg Thieme Verlag KG Stuttgart · New York

Colonoscopy-assisted percutaneous endoscopic gastrostomy to avoid a gastrocolocutaneous fistula of the transverse colon

Yosho Fukita
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Yoshiki Katakura
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Seitaro Adachi
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Ikuma Yasuda
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Tsutoshi Asaki
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Michifumi Toyomizu
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
,
Hiroyuki Ishibashi
Department of Gastroenterology, Seirei Yokohama Hospital, Yokohama, Kanagawa, Japan
› Institutsangaben
Weitere Informationen

Corresponding author

Yosho Fukita, MD, PhD
Department of Gastroenterology
Seirei Yokohama Hospital
215 Iwai-cho, Hodogaya-ku
Yokohama, Kanagawa-pref
Japan 240-8521   
Fax: +81-45-7153387   

Publikationsverlauf

Publikationsdatum:
12. Februar 2014 (online)

 

An 80-year-old woman with a nasogastric tube in situ for cerebral infarction sequelae was referred for percutaneous endoscopic gastrostomy (PEG). The abdominal computed tomography scan on admission showed that the transverse colon was interposed between the anterior abdominal wall and the stomach ([Fig. 1]). The usual PEG placement posed a high risk of piercing the transverse colon. A fluoroscopy-assisted colonoscopy was performed, which showed that the transverse colon was present in the upper abdomen ([Fig. 2 a]). While maintaining the tip of the colonoscope at the hepatic flexure, the transverse colon was moved toward the pelvis under fluoroscopic guidance by using a twisting maneuver of the scope shaft. While the colonoscope was in situ, the esophagogastroduodenoscope was inserted ([Fig. 2 b]). The stomach was expanded as usual to perform the PEG. PEG feeding was initiated as usual without problems. When the PEG button was replaced with a new one 6 months later, no specific abnormalities were observed.

Zoom Image
Fig. 1 Abdominal computed tomography showed that the transverse colon was interposed between the anterior abdominal wall and the stomach.

Fig. 2 Fluoroscopy-assisted colonoscopy to aid percutaneous endoscopic gastrostomy. a A fluoroscopy-assisted colonoscopy showed that the transverse colon was present in the upper abdomen. Water-soluble contrast medium introduced from the distal end of the scope was seen. b The transverse colon was moved toward the pelvis under fluoroscopic guidance by using a twisting maneuver of the scope shaft. While the colonoscope was in situ, the upper gastrointestinal endoscope was inserted.

Zoom Image
Zoom Image

A gastrocolocutaneous fistula is a rare complication of PEG [1] [2]. It results from the interposition of the colon between the anterior abdominal and gastric walls, so the PEG tube inadvertently passes through the colon into the stomach, resulting in the development of an iatrogenic fistula. The risk of this complication increases in cases of megacolon, subphrenic transposition of the colon, a history of abdominal surgery, or overinflation of the stomach [1] [2].

Colonoscopy-assisted PEG insertion is slightly different from conventional endoscopic methods in terms of its approach. To the best of our knowledge, only one study used both a colonoscope and an esophagogastroduodenoscope for PEG placement [3]. In that report, Tominaga et al. used fluoroscopy to detect sigmoid interposition between the abdominal wall and the stomach; subsequent evacuation of gas from the sigmoid using colonoscopy resulted in successful PEG placement. In the present case, colonoscopy was used to move the transverse colon toward the pelvis under fluoroscopic guidance. Serious complications can be prevented using this method.

Endoscopy_UCTN_Code_TTT_1AO_2AK


#

Competing interests: None

  • References

  • 1 Friedmann R, Feldman H, Sonnenblick M. Misplacement of percutaneously inserted gastrostomy tube into the colon: report of 6 cases and review of the literature. JPEN J Parenter Enteral Nutr 2007; 31: 469-476
  • 2 Schrag SP, Sharma R, Jaik NP et al. Complications related to percutaneous endoscopic gastrostomy (PEG) tubes. A comprehensive clinical review. J Gastrointestin Liver Dis 2007; 16: 407-418
  • 3 Tominaga K, Saigusa Y, Ito S et al. Percutaneous endoscopic gastrostomy with the aid of a colonoscope to avoid gastrocolic fistula formation. Endoscopy 2007; 39 (Suppl. 01) E112-113

Corresponding author

Yosho Fukita, MD, PhD
Department of Gastroenterology
Seirei Yokohama Hospital
215 Iwai-cho, Hodogaya-ku
Yokohama, Kanagawa-pref
Japan 240-8521   
Fax: +81-45-7153387   

  • References

  • 1 Friedmann R, Feldman H, Sonnenblick M. Misplacement of percutaneously inserted gastrostomy tube into the colon: report of 6 cases and review of the literature. JPEN J Parenter Enteral Nutr 2007; 31: 469-476
  • 2 Schrag SP, Sharma R, Jaik NP et al. Complications related to percutaneous endoscopic gastrostomy (PEG) tubes. A comprehensive clinical review. J Gastrointestin Liver Dis 2007; 16: 407-418
  • 3 Tominaga K, Saigusa Y, Ito S et al. Percutaneous endoscopic gastrostomy with the aid of a colonoscope to avoid gastrocolic fistula formation. Endoscopy 2007; 39 (Suppl. 01) E112-113

Zoom Image
Fig. 1 Abdominal computed tomography showed that the transverse colon was interposed between the anterior abdominal wall and the stomach.
Zoom Image
Zoom Image