Keywords
human chorionic gonadotropin - β subunit - premature rupture of fetal membranes -
diagnosis - obstetrics - pregnancy complications
Palavras-chave
gonadotrofina coriônica humana - subunidade β - ruptura prematura de membranas fetais
- diagnóstico - obstetrícia - complicações na gravidez
Introduction
Premature rupture of fetal membranes (PROM) is the rupture of the chorionic membranes
prior to labor at any time during the pregnancy. Its prevalence ranges from 8–19.53%
of term pregnancies, and from 2–25% of all pregnancies. Traditionally, the diagnosis
of PROM involves vaginal discharge history of amniotic fluid verified at speculum
examination with the ferning test in the microscopic exam and the nitrazine test of
the vaginal discharge.[1]
[2] The early and accurate diagnosis of PROM is very important to start the correct
treatment, enabling good perinatal outcomes and minimizing complications rates and
clinical damage.[2]
[3]
Infection is the most common complication of PROM, and the incidence of this damage
is more frequent the longer is the latency period of delay in the diagnosis.[4] Moreover, other complications include prolonged and preterm labor, cord accident,
neonatal sepsis, respiratory distress syndrome, and increase in perinatal mortality
especially associated with prematurity.[1]
[5]
[6]
The best method to confirm PROM is a visible leakage of amniotic fluid from the cervix,
although this method is associated with 12–30% of false negative results. The sensibility
of the ferning and nitrazine tests ranges from 42–81%.[7] A long latency period is more connected to a wrong diagnosis due to the paucity
of amniotic fluid in the posterior fornix. The same difficulty occurs with the nitrazine
test: after 48 hours of latency, this test shows 9.4% of false negative results. Furthermore,
cervicitis, vaginitis, the presence of alkaline urine in the vaginal fluid, semen,
blood and antiseptics are associated to 17.4% of false positive results.[8] The ferning test also is affected by the same factors: the false negative rate ranges
from 13–30%, and the false positive rate ranges from 5–30%.[1]
Thus, when the loss of amniotic fluid is clear, the diagnosis is easy. On the other
hand, it becomes difficult or impossible in long latency periods or when the rupture
was discreet and high, which leads to the discharge of a scarce amount of amniotic
fluid. Complex cases lead to false positive results that, in turn, can lead to wrong,
high-cost treatments, like hospitalization and labor induction. However, the absence
of a correct diagnosis is harmful, because the patient may not receive the appropriate
assistance, such as antibiotic and corticosteroid therapies.[1]
[2]
[4]
[9] Therefore, new biochemical methods for early and accurate diagnoses are necessary.[10]
Due to the absence of a golden standard method for the diagnosis of PROM, many studies
have been performed to find an easy test that is definitive, noninvasive, and able
to improve the diagnosis of PROM.[2] Current studies emphasize research on biochemical agents found at high levels in
the amniotic fluid: prolactin, α-fetoprotein, insulin-like growth factor, fetal fibronectin,
urea, lactate, placental alpha microglobulin-1, diamine oxidase, human chorionic gonadotropin
(hCG), and creatine.[2]
[3]
[4]
[8]
[9]
[11]
[12]
[13]
[14]
Most of these tests are not popular because they have high costs and complexity.[2] Out of all biochemical markers studied, we highlight the hCG β subunit (β-hCG).
The β-hCG test has an easy determination, fast result, low cost, and many studies
suggest high sensibility and specificity for the diagnosis of PROM.
The hCG is a glycoprotein produced by trophoblastic tissue, and it is present in varying
levels in the blood, urine and amniotic fluid. During pregnancy, the level of hCG
in the blood increases progressively until it reaches 54,000 mUI/mL in 8 to 12 weeks
of gestation. Subsequently, there is a decrease in the levels of hCG in the blood
to 12,000 mUI/mL around 20 gestational weeks. The hCG is present in the amniotic fluid,
in the maternal urine, and its concentration ranges from 2,000 to 70,000 mUI/mL. This
marker is released by cervical glands that are responsible for its presence in the
vaginal fluid. However, there is little information about the level of β-hCG in the
vaginal fluid and its fluctuation between the three pregnancy trimesters.[4]
[8]
[10]
Quantitative analysis of the β-hCG is expensive and takes time, but the qualitative
analysis is simple, fast, inexpensive, and can be used in the diagnosis of PROM. Therefore,
it is possible that the pregnancy test over the threshold to the β-hCG level in the
vaginal discharge in a normal pregnancy.[8]
[11]
Given the aforementioned data, the present study advocates the qualitative analysis
of the hCG with cut-off points of 10 mIU/mL (β-hCG-10) and 25 mIU/mL (β-hCG-25) in the vaginal fluid washings of pregnancies with PROM. In order to do this,
we used the calculations of sensibility, specificity, positive predictive value (PPV),
negative predictive value (NPV), accuracy, likelihood ratio for a positive test result
(LR+), and likelihood ratio for a negative test result (LR-). This analysis aims to
launch the development and validation of new technology in the early diagnosis of
PROM.
Methods
A cross-sectional, prospective and analytic study of pregnant women between gestational
weeks 24 and 39 attending a university hospital in the state of Paraná, Brazil. The
sample population was divided into two groups: group A (pregnant women clinically
diagnosed with PROM) and group B (pregnant women without loss of amniotic liquid).
The study's exclusion criteria were: presence of uterine dynamic; fetal distress;
and presence of blood in the vaginal fluid. The diagnosis of PROM was made after the
amniotic fluid flow was observed through the hole cervical during the vaginal speculum
exam. Moreover, the diagnosis was complemented by the results of the nitrazine test,
with a pH ≥ 6, and the fern test of the vaginal fluid. The patients were subjected
to a vaginal fluid washing with 3 mL of saline solution, which was aspirated subsequently
with the same syringe and sent directly to the laboratory. The remaining solution
was centrifuged (1,500 rpm), and it was qualitatively tested for the presence of β-hCG-25
and β-hCG-10.
The data analysis was performed using the chi-squared test with Yates' correction
and Fisher's exact test. For the statistical analysis, a 95% confidence interval (95%CI)
was considered, and values of p < 0.05 were considered statistically significant. First, the data were tabulated
using the Microsoft Excel software (Microsoft Corporation, Redmond, WA, US), and the
data were analyzed using the Epi Info software, version 3.5.2 (Centers for Disease
Control and Prevention, Atlanta, GA, US), and the Statistical Analysis System (SAS),
version 9.4 (SAS Institute, Cary, NC, US).
The study was submitted to the Ethics Committee of one of our institutions and approved
under protocol number 515/2009. All participants signed a free and informed consent
form (FICF), and the research followed the Helsinki Declaration, which was reviewed
in 2008.
Results
The analysis was performed on 177 pregnant women. The β-hCG-10 test was performed
on 128 (72.3%) pregnant women, 57 (44.6%) of which belonged to group A (those with
PROM), and 71 to group B (those without loss of amniotic liquid). The β-hCG-25 test
was performed on 49 (27.7%) pregnant women, 18 (36.7%) of which belonged to group
A, and 31 (63.3%) to group B.
The β-HCG-10 test of the vaginal fluid was positive in 44 (34.4%) women in group A, and
in 40 (31.2%) women in group B; therefore, there were 13 (10.2%) cases of false negative
results. The statistical analysis using the chi-squared test with Yates' correction
showed a statistically significant difference between the groups (p = 0.0225) for the β-HCG-10 test ([Table 1]).
Table 1
Distribution of the pregnant women in group A (PROM) and group B (control) according
to the β-hCG-10 test of vaginal washes. Maringá, Paraná, Brazil, 2015
|
β-
h
CG-10 test
|
Group A
(PROM)
|
Group B
(control)
|
TOTAL
|
|
N
|
%
|
N
|
%
|
N
|
%
|
|
Positive
|
44
|
34.4
|
40
|
31.2
|
84
|
65.6
|
|
Negative
|
13
|
10.2
|
31
|
24.2
|
44
|
34.4
|
|
TOTAL
|
57
|
44.6
|
71
|
55.4
|
128
|
100
|
Abbreviations: β-hCG-10, human chorionic gonadotropin β subunit test with a cut-off
point of 10 mIU/mL; PROM, premature rupture of fetal membranes.
Notes: Chi-squared test (χ2) = 5.21; p = 0.0225; Yates' correction for continuity; odds ratio (OR) = 2.62 (1.13–6.15).
The β-hCG-10 vaginal test had 77.1% of sensitivity, 43.6% of specificity, 52.3% (44/84)
of PPV, 70.4% (31/44) of NPV, and 58.6% (75/128) of accuracy in the diagnosis of PROM.
The likelihood ratio for a positive test result (LR+) was 1.37, and the likelihood
ratio for a negative test result (LR-) was 0.50.
The β-hCG-25 test of the vaginal fluid was positive in 8 (16.3%) cases in group A,
and in 4 (8.2%) cases in group B, with 10 (20.4%) cases of false negatives. The statistical
analysis using Fisher's exact test showed a statistically significant difference between
the groups for the β-hCG-25 vaginal test (p = 0.0175) ([Table 2]).
Table 2
Distribution of the pregnant women in group A (PROM) and group B (control) according
to the β-hCG 25 test of vaginal washes. Maringá, Paraná, Brazil, 2015
|
β
-
hCG 25
|
Group A
(PROM)
|
Group B
(control)
|
Total
|
|
N
|
%
|
N
|
%
|
N
|
%
|
|
Positive
|
8
|
16.3
|
4
|
8.2
|
12
|
24.5
|
|
Negative
|
10
|
20.4
|
27
|
55.1
|
37
|
75.5
|
|
TOTAL
|
18
|
36.7
|
31
|
63.3
|
49
|
100
|
Abbreviations: β-hCG-25, human chorionic gonadotropin β subunit test with a cut-off
point of 25 mIU/mL; PROM, premature rupture of fetal membranes.
Notes: Chi-squared test (χ2) = 4.54; p = 0.0175; Fisher's exact test; odds ratio (OR) = 5.40 (1.11–28.10).
The β-hCG-25 vaginal test had 44.4% of sensitivity, 87.1% of specificity, 66.6% (8/12)
of PPV, 72.9% (27/37) of NPV and an accuracy of 71.4% in the diagnosis of PROM. The
LR+ was of 3.41 and the LR- was of 0.63.
Discussion
The qualitative hCG test for the diagnosis of PROM has shown to be a better method
than the traditional diagnosis methods like the ferning and nitrazine (pH) tests and
the speculum exam. The hCG measurement is not modified by the same factors as the
ferning and nitrazine tests. In fact, the speculum exam is of no help when it is performed
after a long latency period, while a high hCG concentration can be measured in the
vaginal fluid 24 hours after the PROM.[1]
The determination of the amount of β-hCG-25 in the vaginal fluid can be used as a
good method for the diagnosis of PROM, and it had an accuracy of 71.4% in the present
study. In the literature, this method was reported to have an accuracy of 87%.[8]
The β-hCG-25 test had low sensitivity (44.4%), probably due to the fewer PROM samples
used in the present study. This hypothesis is supported by other studies with better
results, which used the same cut-off point, but had larger samples.[8]
[9]
[12] On the other hand, this test provided a good amount of specificity (87.1%), which
shows its good diagnosis power. Moreover, we achieved specificity rates that were
higher than those of many previous studies, which reported specificity rates of 68%,
84%, 86%, for example.[13]
[14]
[15]
In the present study, the β-hCG-10 and β-hCG-25 tests provided NPVs of 70.4% and 72.9%
respectively. These results were better than the NPV of another study that used a
bigger cut-off point (100 mUI/mL).[4]
Likelihood ratio is the ratio between the probability of a result at a diagnosis test
in people with a disease and the probability of getting the same result in healthy
people. So, for the β-hCG-10 test, the LR+ of 1.37 is the chance to find a positive
result in people with PROM (true positive), and it is similar to finding a positive
result in healthy people (false positive). The LR- of 0.5 means that the chance to
find a false negative result relative to a true negative result is of 50:100, or that
the chance of a negative outcome being true for this cut-off point relative to a false
negative result is of 2.00. A negative result for this cut-off point can help us reasonably
distinguish a healthy person from someone with PROM.
For the β-hCG-25 test, the LR+ of 3.41 means that, for this cut-off point, the chance
that the test result is a true positive is 3.41 times higher than the chance of the
test result being a false positive. In this case, a positive result can help us distinguish
those with PROM from the healthy subjects. The LR- of 0.63 means that the chance the
negative test result is false is of 63:100; in other words, the chance a negative
test result is true for this cut-off point is 1.58 times higher than the chance a
negative test result is false. The accuracy of the β-hCG-10 test was of 0.58, and
for the β-hCG-25 test, it was of 0.71.
When the two cut-off points of the present study are compared, it is possible to notice
that the β-hCG-25 test has a greater discriminatory power for PROM than the β-hCG-10
test.
Many studies discuss the ideal cut-off point for the hCG test for the diagnosis of
PROM.[16] In our review, the major cut-off point studied was of 100 mUI/mL, and it provided
a sensibility of 71.2%, a specificity of 100%, a PPV of 100%, and an NPV of 65.1%;
even though there was a high specificity with this cut-off point, it showed lower
sensibility.[4] A cut-off point of 39.8 mUI/mL was also studied, and all parameters were higher
than 90%, so the literature suggests that this is a good value to be considered.[16] Researchers had who used a cut-off point ≤ 25 mUI/mL also achieved sensibility and
specificity rates higher than than 90%, which suggest this can be an appropriate value.[1]
[12]
[17]
[18]
During pregnancy, the cervical glands release hCG in the vaginal fluid, but the concentration
remains lower than 10 mUI/mL after the 20th gestational week,[1] which supports the possibility of performing the β-hCG qualitative test with a cut-off
point of 10 mUI/mL. However, in this study, the β-hCG-10 test provided a low accuracy
(58.6%).
The mean level of β-hCG in the vaginal fluid in a pregnancy with intact membranes
varies throughout the pregnancy from 37.9 mUI/mL in the first trimester to 9.5 mUI/mL
in the second trimester, and from 6.3 to 7.71 mUI/mL in the third trimester. On the
other hand, the β-hCG levels in pregnancies with PROM in the literature ranges from
330.88 to 468.06 mUI/mL.[1]
[11]
[14]
Due to the variation in β-hCG levels during different trimesters, it is valid to argue
that the accuracy of the parameters may vary throughout pregnancy. In the literature,
few studies evaluated this fact, although when is done this analysis, the β-hCG provides
better sensibility in second trimester, which suggest that it is an opportunity for
this pregnancy period.[3]
[10] Our data analysis did not discern the parameters for each trimester, so it is not
possible to compare the data for every trimester. We suggest that future studies with
bigger samples should perform this analysis.
Another PROM marker with easy access and excellent parameter is creatinine. The literature
reports that creatinine is a better PROM marker than β-hCG,[2]
[18] with an accuracy of 100%. This information shows it is necessary to evaluate creatinine
as another good PROM marker.[15]
The hCG test should not be performed in the presence of blood, because vaginal bleeding
can lead to false positive results due to the high hCG concentration in the blood.[8] Thus, a false positive PROM result can lead to unnecessary interventions, such as
hospitalization, antibiotic therapy, corticosteroid therapy and labor induction.[2]
[17]
Therefore, it is important to keep searching for the ideal PROM maker, which is present
in the amniotic fluid, has a long half-life, and can be detected throughout pregnancy.
The test quality should not depend on the presence of blood, urine, feces, semen or
others topic products that may be present in the vaginal fluid.[5]
[7] Moreover, an ideal biomarker should provide a high concentration of amniotic fluid,
low blood concentration, and an extremely low concentration in the vaginal fluid in
pregnancies with intact fetal membranes.[5] Many markers have been studied, and the β-hCG is among the most simple, easy to
use, and cheap.[14] Thus, the β-hCG test may be a practicable possibility for the diagnosis of PROM,
although more studies are needed on its efficacy, and a consensus must be reached
on the ideal cut-off points for the different trimesters. The description of several
cut-off points may be explained by the difference in the sample size of the studies
and the different inclusion and exclusion criteria.
The present study does not aim to set a definitive cut-off point; its goal is to evaluate
the pregnancy test used for the diagnosis of PROM. In light of the aforementioned
data, the β-hCG may be a practicable possibility for the diagnosis of PROM because
it is a simple and fast exam that can be performed without any sophisticated equipment.
This study can help health care managers make decisions to implement improvements
in health care policies for the promotion of health and the prevention of diseases
in women.