Vet Comp Orthop Traumatol 2000; 13(03): 115-118
DOI: 10.1055/s-0038-1632644
Clinical Communication
Schattauer GmbH

Ovine hip hemiarthroplasty: reducing dislocation

D. G. Dunlop
1   Princess Margaret Rose Orthopedic Hospital, Edinburgh, Scotland
,
J. R. Field
2   Repatriation General Hospital, Orthopedic Unit, Daw Park, South Australia, Australia
› Author Affiliations
Further Information

Publication History

Received 02 December 1999

Accepted 04 May 2000

Publication Date:
09 February 2018 (online)

We present a surgical modification which can be performed during hip hemiarthroplasty, in the ovine model, that may significantly reduce the perioperative dislocation rate. A modified tenorrhaphy technique was performed on the tendinous insertion of the accessory gluteal muscle during wound closure following hemiarthroplasty. Subsequently only one of sixteen animals (6%) dislocated. This compares favourably with other studies in which significantly higher rates of dislocation have been reported. The macroscopic appearance of the repair was assessed at the time of necropsy and found to be satisfactory.

 
  • REFERENCES

  • 1 Bruns DP, Olmstead ML, Litsky AS. Technique and results for total hip replacement in sheep: An experimental model. Vet Comp Orthop Traumatol 1996; 09: 158-64.
  • 2 Field JR, Aberman H, Carbone A, Sharpe P, Smith N, Dunlop DG, Howie DW. An ovine model for total hip replacement: Operative procedure and complications. Vet Comp Orthop Traumatol. in press.
  • 3 Dunlop DG, Griffon D, Howie CR. et al. An ovine model to evaluate impacted pellets of new synthetic bone graft substitutes. J Bone Jt Surg. 2000 81-B. Supp I.
  • 4 Dunlop DG, Field JR, Costi J. et al. Design and evaluation of a device for measuring 3-D micromotions of impaction grafted cemented femoral stem prosthesis. J Royal Coll Surg; Edinburgh: 1999
  • 5 Newman E, Turner AS, Wark JD. The potential of sheep for the study of osteopenia: Current status and comparison with other animal models. Bone 1995; 16: 277S-84S.
  • 6 Turner AS, Eckhoff DG, Dewell RD. Periapatite coated implants improve fixation in osteoporotic bone. 44th Ann Meeting Orthop Res Soc New Orleans; Louisiana: 1998
  • 7 Wang AW. Femoral bone remodelling following cemented hip arthroplasty in a sheep model. PhD Thesis, University of Adelaide; 1998: 52-62.
  • 8 Brumby SA, Howie DW, Pearcy MJ, Wang AW, Nawana NS. Radiographic and histologic analysis of cemented double-tapered femoral stems. Clin Orthop Rel Res 1998; 355: 229-37.
  • 9 Olmstead ML, Hohn RB, Turner TM. A five year study of 221 total hip replacements in the dog. J Am Vet Med Assoc 1983; 183: 191-4.
  • 10 Montgomery RD, Milton JL, Pernell R, Aberman HM. Total hip arthroplasty for treatment of canine hip dysplasia. Vet Clin Nth Amer 1992; 22: 703-19.
  • 11 Sumner DR, Turner TM, Urban RM, Galante JO. Remodeling and ingrowth of bone at two years in a canine cementless total hip-arthroplasty model. J Bone Joint Surg (Am) 1989; 74: 239-50.
  • 12 Rashmir-Raven AM, DeYoung DJ, Abrams CF, Aberman HA, Richardson DC. Subsidence of an uncemented canine femoral stem. Vet Surg 1992; 21: 327-31.
  • 13 De Young DJ, DeYoung BA, Abrams CF, Kenna RV, Hungerford DS. Implantation of an uncemented total hip prosthesis. Technique and initial results of 100 arthroplasties. Vet Surg 1992; 21: 168-77.
  • 14 Radin EL, Rubin CT, Thrasher EL. et al. Changes in the cement-bone interface after total hip replacement. J Bone Jt Surg (Am) 1982; 64-A: 1188-200.
  • 15 Kelley SS, Lachiewicz PE, Hickman JM. et al. Relationship of femoral head and acetabular size to the prevalence of dislocation. Clin Orthop Rel Res 1998; 355: 163-70.
  • 16 Turner RS. Postoperative total hip prosthetic femoral head dislocations. Clin Orthop Rel Res 1994; 301: 196-204.
  • 17 Cave EP, Rowe CR. Capsular repair for recurrent dislocation of the shoulder: Pathologic findings and operative technique. Surgical Clin Nth Amer 1947; 27: 1289-93.