Keywords
patient safety - quality improvement - platelet transfusion - clinical decision support
systems - human–computer interaction
Background and Significance
Background and Significance
As increasing attention is directed toward preventing medical errors, new emphasis
has been placed on the use of clinical information systems, including clinical decision
support (CDS) and computerized provider order entry (CPOE), to improve health care
quality and patient safety.[1]
[2] The expansion of CDS and CPOE was accelerated by the Health Information Technology
for Economic and Clinical Health Act, which created incentives for the “meaningful
use” of the electronic health record (EHR) to improve health care quality.[3] CDS systems can provide evidence-based recommendations integrated into a provider's
clinical workflow and may include order sets, alerts, reminders, and drug dosing recommendations.[4]
[5]
[6]
[7]
[8] CDS and CPOE have frequently been shown to improve guideline adherence,[5]
[9]
[10]
[11]
[12]
[13]
[14]
[15] prevent medical errors,[12]
[16]
[17]
[18]
[19] and improve health care quality.[5]
[20]
[21]
[22]
[23]
[24] Unfortunately, CPOE and CDS have also been shown to generate unintended consequences,
including the creation of previously unanticipated errors.[25]
[26]
[27]
[28]
[29]
[30] Many of these unintended consequences can lead to adverse events which go undetected.[29]
[31] An example of this new kind of error includes a “juxtaposition” error, where a user
unknowingly selects the wrong option between choices that were adjacent to one another
in a selectable list.[26]
[27] Guidelines exist for the development, governance, and monitoring of CPOE and CDS
systems; however, they were not available when our institution implemented our EHR.[32]
Prophylactic platelet transfusion is widely recommended to prevent spontaneous hemorrhage
in severely thrombocytopenic patients.[33] Pediatric platelet transfusion volume is typically weight based.[34] Transfusing less than the recommended volume could lead to increased risk of severe
or life-threatening hemorrhage.[35] Additionally, repeated exposure to platelet products puts patients at increased
risk for transfusion-related adverse events like infections, transfusion-related acute
lung injury, and anaphylaxis.[35]
[36]
[37] At our hospital, development of order sets at different times for different services
led to the existence of similar order sets that provide recommendations for weight-based
pediatric platelet transfusion volume. Prior studies have shown that CDS can reduce
ordering errors for blood products, but that physician noncompliance with recommendations
remained high.[38]
[39]
Objectives
The aim of this study was to (1) determine the frequency of platelet transfusion ordering
errors using commonly used platelet transfusion order sets. Because we hypothesized
that the error rates would differ between different order sets, we also aimed to (2)
reduce the number of platelet transfusion ordering errors by 50% using the order set
identified to have the highest percentage of ordering errors; and (3) to create a
generalizable model for the postimplementation monitoring of commonly utilized CDS
tools at our institution.
Methods
Setting
The study was conducted at Boston Children's Hospital in Boston, Massachusetts, United
States, which is a 404-bed tertiary pediatric care hospital. This hospital trains
fellows, residents, and medical students.
Our hospital utilizes a commercial EHR with customized order sets and other CDS. During
the initial implementation of CPOE and CDS, the clinical informatics team designed
and implemented order sets based on the clinical recommendations from subject matter
experts. After the initial implementation of order sets, development of subsequent
order sets was decentralized, leading to variation in order set design. Some years
later, a Clinical Orders Oversight Committee was developed to provide governance over
maintenance of existing order sets and creation of new ones. The Clinical Orders Oversight
Committee includes physician and nurse informaticists, information technology staff,
as well as staff from most functional departments in the hospital (i.e., laboratory
staff, radiology staff, among others).
For this quality improvement (QI) initiative, we identified all order sets that provide
recommendations for weight-based pediatric platelet transfusion volume. We focused
on the two most commonly used order sets and orders placed without the use of an order
set. The first order set is intended for use in Inpatient Service 1 and was created
during the initial CPOE implementation. The other, intended for use in Inpatient Service
2, was developed several years later. One service is a pediatric intensive care unit
(ICU), and the other is an inpatient pediatric hematology/oncology service. Although
the patient populations on these units are different, those receiving platelet transfusions
are often the same, and the transfusion volume recommendations are the same.
Design
In the initial planning phase for the study, we reviewed all existing platelet transfusion
ordering CDS at a tertiary care pediatric hospital. Next, a retrospective cohort study
was conducted to compare order error rates for platelet transfusions placed using
the two mostly commonly used order sets, the Inpatient Service 1 and Inpatient Service
2 order sets, as well as orders placed without the use of any order set. Based on
preliminary data review, we focused specifically on the order set with the highest
order error percentage, Inpatient Service 1. The results of this study and our critical
evaluation of the platelet transfusion order sets were reviewed with our Clinical
Orders Oversight Committee.
Intervention
Based on preliminary data review, the display of the Inpatient Service 1 order set
was modified. The original Inpatient Service 1 order set display had check boxes flanked
by two different weight parameters, and required users to select a box for the appropriate
weight category to place the order ([Fig. 1]). Each weight category has a recommended number of units of platelets for transfusion,
with the volume of each unit approximately 20 to 40 mL. The display was updated using
user-centered design principles to improve usability and reduce undertransfusion ordering
errors ([Fig. 1]). After these modifications, the revised Inpatient Service 1 order set was reviewed
by key stakeholders in the Inpatient Service 1 department including multiple nurse
practitioners, attending providers, and the resident rotation director. The order
set was additionally reviewed by the Clinical Orders Oversight Committee prior to
implementation. After this updated order set was implemented, a quasi-experimental
time-series design was used to track undertransfusion ordering errors prospectively.[40]
Fig. 1 Order sets.
All platelet transfusion orders placed over the previous year were collected and reviewed.
The results of this review and the above changes were presented at an Inpatient Service
1 Mortality and Morbidity Conference.
Data Collection
We queried our enterprise data warehouse to identify all platelet transfusion orders
that were placed from January 1, 2017 through December 12, 2017 (baseline period).
We excluded platelet transfusion orders that were placed in preparation for surgery
or other invasive procedures as we were specifically interested in prophylactic transfusion
in the setting of thrombocytopenia, which was the clinical indication for use of the
existing order sets. Additionally, we excluded orders placed in the cardiac ICU as
those patients often had both different indications and thresholds for platelet transfusion
as well as a clinical indication for transfusing lower platelet volumes due to the
extreme fluid sensitivity of the patient population. Subsequently, we prospectively
followed all platelet transfusion orders placed using the two most commonly used order
sets (Inpatient Service 1 and Inpatient Service 2 order sets), as well as orders placed
without the use of any order set, from December 13, 2017 through June 30, 2018 (intervention
period). The same exclusion criteria as above were applied. All suspected errors identified
were confirmed with manual chart review by which included a review of provider documentation
for clinical indications which would justify purposefully limiting transfusion volume.
The manual chart review was performed by two physicians who independently reviewed
the charts of all suspected errors.
Measures
The primary outcome measure was the percentage of platelet transfusion undertransfusion
ordering errors. Errors were defined as platelet transfusion volumes ordered which
were less than the amount recommended by the order set used. We did not characterize
orders placed for greater than the recommended volume of platelets as errors as there
are frequently clinical and patient-specific indications for such orders.
Analysis
For our primary outcome measure, we compared the percentage of ordering errors when
using the Inpatient Service 1 or Inpatient Service 2 order set, or the use of no order
set, during the baseline and intervention periods. A chi-squared test was used to
compare proportions. p-Values of < 0.05 were considered significant. Statistical process control charts
were used to track the outcome measure over time and to assess for special cause variation.
The centerline is the average platelet transfusion order error percentage in the baseline
period. Control charts were created using CHARTrunner version 3.0 (PQ Systems, Dayton,
Ohio, United States). Special cause variation was defined as a run of 6 or more consecutive
points above or below the centerline, signaling a shift.[41] The interrater agreement of the manual chart review was measured using a kappa statistic.
An additional subgroup analysis was done to exclude errors when the ordering weight
was within 1 kg of the category below as this could have been ordered at the clinician's
discretion, given the proximity to the lower weight category. For example, if the
patient weighed 12.7 kg, and was ordered for the platelet transfusion volume recommended
for the less than 12 kg category, this would not count as an error in this subgroup
analysis.
Results
We identified six different ways in which platelet transfusions were ordered, including
five unique order sets and placing an order without the use of any order set. Sixty-two
percent of all platelet transfusion orders were placed using either the Inpatient
Service 1 or Inpatient Service 2 platelet transfusion order set, while 35% were placed
without the use of any order set, and approximately 4% used another platelet transfusion
order set. We did not analyze the order sets used for this 4% of orders given the
low usage rate. About 1% of orders were placed using one of two remaining order sets,
which were not analyzed given the low rate of usage. We found that orders placed without
the use of any order set increased from 33% of all orders in the preintervention period
to 37% of all orders placed in the postintervention period (p-value < 0.05).
We identified 4,144 platelet transfusion orders that were placed using either the
Inpatient Service 1 or Inpatient Service 2 order set. We additionally identified 2,111
orders that were placed without the use of any order set. Of the orders placed with
the Inpatient Service 1 or Inpatient Service 2 order set, or placed without use of
any order set, 1,221 were excluded based on the exclusion criteria above leaving 5,034
platelet transfusion orders in the analysis. These orders were placed for 472 unique
patients, with each patient receiving an average of 10.3 platelet transfusions. Of
the included orders, 3,083 were from the baseline period, and 1,951 were from the
intervention period. Chart review of suspected platelet ordering errors did not identify
any documentation to suggest platelet transfusion was purposefully limited due to
clinical concerns of volume overload or any other reason. There was excellent agreement
between the two independent physicians' chart review (κ = 0.91). Using the weight-based
recommendations in the order sets, 69 errors were identified (1.4% of all platelet
orders). Of those errors, 53 resulted in undertransfusion (77%). The remaining 23%
of ordering errors were corrected before the transfusion occurred. In every instance
of ordering error when an order set was used, the ordered volume corresponded to the
expected volume for the weight range below the patient's.
In the baseline time period, we identified significantly more undertransfusion ordering
errors on orders placed using the Inpatient Service 1 as compared with the Inpatient
Service 2 order set ([Table 1]). Additionally, we identified significantly more undertransfusion ordering errors
on orders placed using the Inpatient Service 1 order set as compared with use of no
order set. The percentage of platelet undertransfusion ordering errors using the Inpatient
Service 1 order set decreased from a mean of 3.1% in the baseline period to a mean
of 0.3% in the intervention period ([Fig. 2]). The decrease in the platelet undertransfusion ordering error occurrence coincided
with the implementation of the revised order set. After revision, there were significantly
fewer errors on orders placed using the Inpatient Service 1 order set as compared
with the use of no order set. There was no significant difference between the use
of the Inpatient Service 1 or Inpatient Service 2 order set in the intervention period.
The percentage of platelet undertransfusion ordering errors using the Inpatient Service
2 order set did not change significantly from the baseline to the intervention period.
Table 1
Platelet transfusion ordering errors using the Inpatient Service 1 and Inpatient Service
2 order sets
|
Baseline period (1/1/17–12/12/17)
|
Orders
|
Errors
|
Percentage errors
|
p-Value
|
|
Inpatient Service 1 order set (original order set)
|
1,249
|
39
|
3.1%
|
|
|
Inpatient Service 2 order set
|
740
|
9
|
1.2%
|
< 0.05[a]
|
|
No order set
|
1,094
|
5
|
0.46%
|
< 0.001[a]
|
|
Intervention period (12/13/17–6/30/18)
|
|
|
|
|
|
Inpatient Service 1 order set (revised order set)
|
897
|
3
|
0.3%
|
< 0.001[a]
|
|
Inpatient Service 2 order set
|
335
|
2
|
0.6%
|
0.52[b]
|
|
No order set
|
719
|
11
|
1.5%
|
< 0.05[c]
|
a
p-Value as compared with Inpatient Service 1 baseline period (original order set).
b
p-Value as compared with Inpatient Service 2 baseline period.
c
p-Value as compared with Inpatient Service 1 intervention period (revised order set).
Fig. 2 Statistical control p-chart: Inpatient Service 1 platelet transfusion order set ordering error rate.
There was no change in the results for the additional subgroup analysis that was done
to exclude errors when the ordering weight was within 1 kg of the category below (data
not shown).
Discussion
Summary
We found that significantly more platelet undertransfusion ordering errors were made
when using the Inpatient Service 1 order set compared with the Inpatient Service 2
order set. Given the display of the original Inpatient Service 1 order set, with each
check box flanked by two different weight parameters, we suspect that the increased
error frequency was the result of juxtaposition errors, which were less likely with
the design of the Inpatient Service 2 order set. This hypothesis is supported by the
rapid decrease in undertransfusion ordering errors for orders placed using the Inpatient
Service 1 order set during the intervention period. Interestingly, even though the
Inpatient Service 2 order set requires users to manually type the platelet volume,
this suggests that there were few or no errors caused by users inadvertently hitting
the wrong key. We found that the number of orders placed without using an order set
increased significantly after implementation of our revised order set. The reason
for this change is unclear, and future QI efforts can assess barriers to use of order
sets and methods to develop new CDS or workflows that would encourage more use. Additionally,
we found that 77% of incorrect orders resulted in actual transfusion of the incorrect
volume of platelets, which suggests these errors frequently go unidentified by both
blood bank and nursing staff when reviewing and approving the orders. This may be
due to lack of awareness of transfusion guidelines, inadequate processes in place
to confirm appropriate dosing, or overreliance on technology.[27] At the time of development of many of our institutional order sets, design options
were limited within our commercial EHR. When the Inpatient Service 1 order set was
developed, the CDS tool placed the actionable item (checkbox) between two lines of
text, making it difficult to clearly associate the actionable item with the relevant
reference text. At the time of development of both the original and revised order
set, we did not have the capability to select a default option based on the most recent
weight documented. While our EHR has always provided the ability for weight-based
dosing of medications, it has not provided the ability for weight-based dosing of
blood products. This capability has subsequently been added, and one of our next steps
will be to modify the order sets to include a default selection. Additionally, like
many other institutions, the individuals designing these first order sets had no formal
training for this process and minimal experience with CPOE. This study demonstrates
how CDS and CPOE can lead to unintended consequences that manifest as silent errors,
which can be difficult to detect even with careful analysis.[26]
[42] At our institution, we did not find any errors reported in our safety event reporting
system or mentioned in review of clinical notes during several months of our baseline
data review, which suggests these errors may go unrecognized by the clinical team.
Moreover, the low overall error ordering rate contributes to the difficulty of recognizing
the recurrence of this type of error. We suggest that the use of collections of clinical
data may help identify patterns in erroneous ordering, which could otherwise go undetected.
As CDS continues to propagate to assist with guideline adherence and QI efforts,[8] designers should recognize the opportunity for error when creating CDS tools.[43] Given that these types of errors can be hard to predict, organizations should utilize
usability testing and postimplementation monitoring to mitigate the risk of unintended
errors.[26]
[42]
[44]
[45]
[46]
The Safety Assurance Factors for Electronic Health Record Resilience guidelines include
usability testing and monitoring as recommended practices for institutions using CDS
and CPOE.[47] Institutions using CDS should have procedures that require regular review of order
sets that includes both a clinical evaluation and patient safety evaluation with data
when possible. Based on the success of our intervention, we propose the following
framework as one potential method for identifying and tracking the effectiveness and
safety of CDS tools ([Fig. 3]). We suggest that there are multiple ways to identify CDS tools for review using
this framework, including: review of all new CDS tools, a random or scheduled screening
of existing CDS tools, or review of CDS tools when there is concern for an issue (e.g.,
through error reports from frontline staff). Additionally, as institutions develop
new CDS tools it is critical to identify measurable outcomes to monitor for errors
prospectively. While this type of testing and monitoring can be costly and time-consuming,
it may provide long-term cost savings through improved adherence to guidelines, decreased
practice variation, and minimizing adverse events, particularly for high-risk therapies,
like blood product administration.
Fig. 3 Framework for tracking effectiveness of clinical decision support tools.
Finally, there is an important role for clinical informaticists as a key part of the
development, approval, and monitoring of CDS. Institutions should ensure they have
enough clinicians who are knowledgeable about informatics and user-centered design
to support safe practices.
Limitations
This study has several limitations. First, we recognize that in our initial baseline
data collection period, we compared order sets developed for use in Inpatient Service
1 to order sets for use in Inpatient Service 2 which care for different, though somewhat
overlapping, patient populations. While these patient populations are different, the
patients receiving platelet transfusions are often the same and the platelet transfusion
recommendations are the same. Second, the proposed approach for tracking effectiveness
of CDS tools is only applicable if there is a measurable outcome. Of course, there
are many types of CDS tools where no simple metric can be created, in which case another
type of postimplementation monitoring would be indicated. Third, though it is known
that transfusing less than the recommend amount of platelets could increase the risk
of hemorrhage or other exposure-related adverse reactions, we did not track the rates
of these occurrences and so cannot comment on whether our revised clinical decision
order set has reduced the risk of these outcomes. Finally, we recognize that the data
reporting infrastructure available at a tertiary care pediatric hospital may not be
available at all organizations, which may limit the generalizability of our approach.
Conclusion
This QI intervention successfully reduced platelet transfusion ordering errors placed
using an order set which could be easily misinterpreted. A similar initiative could
be undertaken for many CDS tools to identify and prevent medical errors and other
unintended consequences of CDS. This type of study will likely become increasingly
important as CDS becomes more ubiquitous.
Clinical Relevance Statement
Clinical Relevance Statement
This study describes one way that clinical decision support design may contribute
to ordering errors. In this study, the order set design was associated with an increased
frequency of ordering an inappropriately low volume platelet transfusion. Ordering
providers and clinical decision support designers should be aware of the way that
design can facilitate or prevent ordering errors. Additionally, this study describes
a framework which could be used to identify and track the effectiveness of similar
clinical decision support tools, which could ultimately reduce or prevent ordering
errors.
Multiple Choice Questions
Multiple Choice Questions
-
The Health Information Technology for Economic and Clinical Health (HITECH) Act created
incentives for which of the following?
-
The meaningful use of the electronic health record to improve health care quality.
-
The use of mobile devices to access and document in the electronic health record.
-
The use of high resolution imaging devices to improve radiological study quality.
-
The use of state-of-the-art laboratory equipment to improve laboratory efficiency.
Correct Answer: The correct answer is option a, the meaningful use of the electronic health record
to improve health care quality. The Health Information Technology for Economic and
Clinical Health (HITECH) was enacted in 2009 under the American Recovery and Reinvestment
Act. The purpose of the Act was to increase adoption, implementation, and encourage
the meaningful use of health information technology.[3]
-
What is a juxtaposition error?
-
Walking to the wrong patient bed when patients are in shared rooms.
-
Inserting a similar sounding but incorrect word when using dictation software.
-
Selecting the wrong ordering option between choices that were adjacent to one another.
-
Placing orders on the wrong patient when multiple tabs are open in the electronic
health record.
Correct Answer: The correct answer is option c. Like the ordering error made in this study, a juxtaposition
error is when a user unknowingly selects the wrong option between choices that were
adjacent to one another in a selectable list. This is an example of an unanticipated
consequence of computerized provider order entry systems.[27]
[28]
-
Which of the following are guidelines that recommend best safety practices for organizations
using electronic health records?
-
American Institute of Electronic Health Record Safety Guidelines.
-
Safety Assurance Factors for Electronic Health Record Resilience (SAFER) Guides.
-
U.S. Preventative Services Task Force Recommendations on Electronic Health Record
Safety.
-
Boston Guidelines for Safe Use of the Electronic Health Record.
Correct Answer: The correct answer is option b, safety Assurance Factors for Electronic Health Record
Resilience (SAFER) Guides. The SAFER guides are self-assessment checklists according
to evidence-based practice for safe electronic health record implementation. These
guides include a recommendation for usability testing and postimplementation monitoring
in organizations using clinical decision support and computerized provider order entry.