Endoscopy 2020; 52(S 01): S80
DOI: 10.1055/s-0040-1704240
ESGE Days 2020 oral presentations
Friday, April 24, 2020 08:30 – 10:30 ERCP complications Liffey Meeting Room 2
© Georg Thieme Verlag KG Stuttgart · New York

SUCCESSFUL CLOSURE OF A LARGE TYPE I ERCP-RELATED PERFORATION WITH AN OVER-THE-SCOPE CLIP (OTSC) DEVICE: A VIDEO REPORT

M Velegraki
1   Venizeleio General Hospital, Department of Gastroenterology, Heraklion, Greece
,
E Vardas
1   Venizeleio General Hospital, Department of Gastroenterology, Heraklion, Greece
,
G Delibaltadakis
2   Venizeleio General Hospital, Department of General Surgery, Heraklion, Greece
,
G Paspatis
1   Venizeleio General Hospital, Department of Gastroenterology, Heraklion, Greece
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
23. April 2020 (online)

 
 

    Duodenal perforations during ERCP are associated with high morbidity and mortality rates. Traditionally, duodenal perforations caused by the duodenoscope itself (Stapfer type I) have been treated surgically. The OTSC is already recommended for the treatment of iatrogenic perforations, but there is scarce data about its use related to ERCP-related duodenal perforations.

    We present the case of a 91-year-old man, diagnosed with pancreatic head cancer, who underwent biliary stenting through ERCP. During the removal of the prophylactic pancreatic stent, a full-thickness defect of 20mm diameter was visible in the superior duodenal flexure. An OTSC successfully closed the perforation without further intervention.


    #