Keywords preheated resin - marginal sealing - indirect restorations - microtensile bond strength - adhesive interface
Introduction
Advances in adhesive dentistry have increased the applications of partial adhesive aesthetic restorations of conservative and aesthetic inlays and onlays. The purpose of these restorations is to preserve and protect the intact structure and healthy remnant of the tooth.[1 ]
[2 ] They are made with ceramic materials that exhibit beneficial mechanical properties and composites that possess an elastic module similar to that of dentin and that can be manufactured with a technique directly in the mouth or indirectly by manually working with a model stone or with computer-aided design/computer-aided manufacturing.[3 ]
Adhesive restorations are continuously subjected to stress and occlusal forces, and composites are materials that best distribute the loads in Class II cavities,[4 ]
[5 ] in that these types of cavities compromise the interproximal walls of the teeth. In addition, these types of cavities are more prone than other types to poor marginal proximal adaptation between the restorative material and the dentary substrate due to limitations in visibility and access to the cavity. The design of the cavity and the contraction caused by polymerization of the composites are considered the main risk factors causing the formation of marginal gaps; [6 ]
[7 ] it has been reported that marginal retention loss is one of the main causes of restoration failure.[8 ] In this type of clinical situation, the indirect technique is recommended because it provides better visualization for marginal adaptation of the material, easy manipulation of the restoration, and allows adjustment of the interproximal contacts.[9 ]
[10 ]
The choice of cementing material for indirect adhesive restoration depends on the thickness of the film formed by the cement, wear resistance, marginal sealing, and photocuring capacity. Indirect adhesive restorations are often bonded with RC that have been developed for use without the need for a bonding agent; their low solubility and viscosity provide a clinically acceptable cement film thickness and have been shown to have better mechanical properties than conventional cements.[11 ]
[12 ]
An alternative cementation material is PR because by increasing its temperature to between 55°and 60°C, its viscosity is reduced. Additionally, its fluidity is reduced by the increased free radical mobility, which facilitates better adaptation to the walls of the cavity, compared with that of conventional cementation materials. PR cementation also results in superior marginal adaptation, reducing microfiltration, and therefore increasing the durability of the restorations,[13 ] which also facilitates the cementing of restorations with a relatively low polymerization contraction. However, the use of the PR technique is considered sensitive due to the strict temperature control required, but it should not cause irreversible damage to the pulp tissue.[14 ]
Marginal integrity and the cementing agent are key factors that determine the success of an adhesive restoration; the ideal cement should not wear out or have cracks. Studies have focused on the use of PR for conservative dentistry, but there is not sufficient information concerning its use as a cementing agent. According to the literature, there is little scientific evidence of the effect of PR as cementing agents for indirect partial adhesive restorations of composites. The objective of this in vitro experimental study was to evaluate the marginal sealing and adhesive interface with scanning electron microscopy (SEM) and Confocal laser microscopy (CLSM) of indirect partial adhesive restorations of composites to dentin in Class II cavities of premolars cemented with RC (Relyx U200; 3M ESPE, Minnesota, United States) and PR (ENA HRi; SYNCA, New York, United States). The bond strength of indirect restorations to dentin was evaluated with the XT Plus C Texture Analyzer (Stable Micro System, United Kingdom). The null hypothesis of this study lies in that there is no difference in marginal sealing, adhesive interface, or the bond strength of indirect composite adhesive restorations utilizing RC and PR.
Materials and Methods
Sample Collection
A total of 30 upper and lower premolars were collected from patients who visited the specialty clinic of the Orthodontics Department of the Universidad Autónoma de San Luis Potosí with indications for extraction by orthodontic treatment, following the acquisition of informed and signed consent. The inclusion criteria were upper and lower premolars without destruction of their clinical crown and root, cavities, fractures, or the presence of previous restorations. All of the specimens were stored in a hydrating medium, and scaling was performed to remove any plaque, calculus, or periodontal tissues. Subsequently, these were washed with saline solution and kept in thymol at 4°C until use, but for no longer than 3 months.
Cavity Preparation
A single operator created Class II cavities (mesio-occlusal, 4 mm in distal-mesial width, 4 mm in the vestibule-palatine plane or buccolingually, and 5 mm in depth); the measurements were performed with a periodontal probe, and the cavities were created with a high-speed turbine (KaVo Kerr; California, United States) with a rounded coarse-grain diamond extreme cutter (3131 Azdent Baistra; Henan, China) and with profuse irrigation. The cutter was changed after every five cavities. The teeth were mounted on an acrylic arch to obtain an impression with an impression tray with holes (Rim Lock; Dentsply, PA, United States) and with the two-step technique with a heavy- and light-addition silicon (Silagum; DMG, Germany), following the manufacturer’s instructions. After 1 hour, the impressions were filled with cast type IV Elite Rock (Zhermack; RO, Italy) to prepare cast portions of 22 g/100 mL.
Preparation and Cementation of the Restorations
A separating layer (MDC, California, United States) was placed into the cavities of the cast models, and the 30 indirect restorations were manufactured with UD2 color dentin composite (ENA HRi, SYNCA) employing the oblique incremental technique with layers of 2 mm thick. Each layer was photopolymerized for 20 seconds at an intensity of 1,200 mW/cm2 (Bluephase N; Ivoclar Vivadent, New York, United States). The samples were randomly distributed into two experimental groups corresponding to the cementing material ([Table 1 ]): group A, 15 restorations cemented with RC (resinous cement) (Relyx U200, 3M ESPE), and group B, 15 composite restorations cemented with PR color UD2 (ENA HRi, SYNCA). All procedures were performed according to manufacturers’ instructions ([Tables 2 ]
[3 ]). The restorations were polished with flexible Sof-Lex finishing and polishing discs (3M ESPE) and were subjected to a thermocycling regimen of 500 cycles with an exposure time of 30 seconds at 4°, 37°, and 57°C to simulate the environment of an oral cavity.
Table 1
Brand and batch number of the preheated resin and dual-cured cementing system
Trade name
Manufacturer
Type of cement
Batch
Relyx U200
3M ESPE, St. Paul, Minnesota, United States USA
Self-adhesive resinous cement
4636189
ENA HRi
ENA HRi, SYNCA, New York, United States
Preheated resin
2017003475
Table 2
Preparation of the composite restoration surface prior to cementing
Trade name
Procedure in composite restoration
Relyx U200
Place the restoration in the ultrasound for 5 minutes and apply two layers of Silane (Ultradent, Utah, United States) for 3 minutes.
ENA HRi
Place the restoration in the ultrasound for 5 minutes and apply two layers of Silane (Ultradent) for 3 minutes and add two layers of adhesive (Single Bond Universal, 3M ESPE) without photocuring.
Table 3
Cementation procedure in the dental substrate
Trade name
Procedure in the dental substrate
Relyx U200
Selective engraving in the enamel with orthophosphoric acid (Scotchbond Universal Adhesive, 3M ESPE) for 20 seconds wash with a water spray for 40 seconds and dry for 5 seconds without fully drying the sample.
Impregnate the cavity with the cement and settle the restoration. Remove the excess before photocuring.
ENA HRi
Selective engraving in the enamel with orthophosphoric acid (Scotchbond Universal Adhesive, 3M ESPE) for 20 seconds wash with a water spray for 40 seconds and dry for 5 seconds without fully drying the sample.
Rub two layers of adhesive (Single Bond Universal, 3M ESPE) for 20 seconds and photocure for 20 seconds.
Impregnate the cavity with preheated resins that was previously in an engine (HRi) at a temperature of 39°to 55°C for 60 minutes and apply it to the cavity floor.
Evaluation of Marginal Sealed and Adhesive Interfaces
The first cut was transversal on the occlusal face, followed by a sectional cut in the wall of the proximal restoration, and finally an internal longitudinal cut was made in the middle part of the restoration ([Fig. 1 ]). The width of the specimens was 1.5 mm, and the cuts were made with a diamond disc with two lights IsoMet Wafering Blades 15 LC (Buehler, Germany). The specimens were polished with 600-, 800-, and 1,000-grit sandpaper to obtain a smooth surface and were thoroughly dehydrated at intervals of 30 minutes in alcohol at concentrations of 25, 40, 50, 75, 80, 90, and 100%, and were coated with 15 to 20 nm gold particles to be observed by SEM (JEOL JSM-6510; JEOL, Massachusetts, United States).
Fig. 1 Schematic view of the transversal occlusal cross-section, external longitudinal sections of the proximal wall of the restoration, and the internal longitudinal section of the restoration.
Evaluation of the Microfiltration
The teeth were covered with two layers of nail varnish on the entire surface, with the exception of the occlusal and mesial faces of the axial faces of the cavities of the specimens, leaving 1 mm free around the sealant edges. The teeth were incubated in a fluorescent solution of rhodamine B (0.02 mg/200 mL sterile distilled water; Sigma-Aldrich, St. Louis, Missouri, United States) for 24 hours followed by a vigorous washing step to remove the excess rhodamine, and were allowed to dry for 72 hours. Subsequently, a 1.5-mm thick proximal case-level cut was made with a two-light diamond disc IsoMet Wafering Blades 15 LC (Buehler) to observe the microfiltration of the fluorescent agent with CLSM (Leica Model DMI4000B, Germany). LASAF (Leica, Germany) was used to obtain images with a ×40 objective; five measurements were made on each image of the rhodamine penetration into the walls and on the floor of the cavity. All samples were observed by the same examiner, and measurements were randomly repeated in a blinded manner.
Microtensile Bond Strength Test
The restorations cemented with RC (resinous cement) and PR were cut crosswise into 1.5-mm discs to be mounted onto a microtensile device (TA. XT Plus C; Stable Micro System), which was utilized to evaluate the composite restorations attached with RC or PR. The parameters employed were a speed of 3 mm/second with a force of 5 g for stretching to evaluate the microtensile bond strength.
Statistical Analysis
Statistical analysis, consisting of a Mann—Whitney U test with 95% confidence intervals was performed with Minitab version 17 statistical software.
Results
Evaluation of Marginal Sealing and Adhesive Interfaces
The descriptive analysis of the SEM micrograph of a longitudinal cut of the indirect composite restorations cemented with RC revealed the presence of gaps in the tooth-restoration junction interface on the cavity floor, and no intimate sealing of the restoration was observed between the RC and dentin at an ×80 magnification ([Fig. 2A ]). At a magnification of × 1,500, there was no smear layer, indicating adhesive failure by a clear separation and the formation of a gap between the dentin and the restoration ([Figs. 2B ]
[2C ]). In restorations cemented with PR, a narrower interface was observed along the walls and the floor of the cavity, a thin layer of PR cement was observed with some short gaps of separation toward the dentin, and resinous tags of the penetration of the PR into the dental substrate were observed ([Fig. 2D ]). At a magnification of ×1,500, the presence of permeable dentin tubules and the formation of a hybrid layer was observed, although there were minor partial adhesive failures. The hybrid layer in this group was characterized by its regularity and its high degree of continuity ([Figs. 2E ]
[F ]).
Fig. 2 Scanning electron micrographs of the longitudinal cut of the seal of the indirect restorations of a composite attached with RC at ×80 (A ) and at high magnification, ×1,500 (B, C ) and cemented with preheated resins at ×80 (D ) and at ×1,500 (E, F ).
In the transverse cuts of the occlusal faces of the surface, the cavity edge—both in the composite restorations cemented with RC and those with PR—was observed to have marginal gaps very similar to those of the longitudinal specimens. In the restorations cemented with RC, longer distance gaps between the dentin and the composite were observed ([Fig. 3A ]), as was adhesive failure and the total absence of a hybrid layer where a separation of the dentin and cement was clearly identified ([Fig. 3B ]). In the case of cemented restorations with PR, there was a close union of the interface between the dentin and the composite ([Fig. 3C ]). At a magnification of ×1,500, the presence of a smear layer was observed, and the hybrid layer was continuous and homogeneous throughout the adhesive interface, demonstrating a better adhesion process ([Fig. 3D ]).
Fig. 3 Representative scanning electron microscopy micrographs of the marginal sealing in the cross-sections of the restorations of indirect resins attached with resinous cement at ×80 (A ) and the adhesive interface at ×1,500 (B) , with the preheated resins cementing agent at a magnification of ×80 (C) , and the adhesive interface at ×1,500 (D ).
In the microfiltration measurements of rhodamine in dentin, an average value of 84.4 µm was obtained in the restorations cemented with RC; for PR, the value was 47.7 µm and no statistically significant difference was determined ([Fig. 4A ]). In the images obtained with CLSM, an increase in the microfiltration of rhodamine on the floor of the cavities was observed compared with the axial walls where RC was used ([Fig. 5A ] vestibular, [5B ] cavity floor, [5C ] face palatine), while for restorations cemented with PR, although greater microfiltration was not observed, the penetration was limited in the marginal mismatch space, where there was no marginal seal ([Fig. 5D ] vestibular wall, [5E ] cavity floor, and [5F ] palatine wall).
Fig. 4 Microleakage results of the values of the penetration of rhodamine in the marginal mismatch in the dentin-resin layer in the vestibular, palatine walls, and the floor of the Class II cavity (A) , and the comparation of the values obtained from the microtensile bond strength of indirect resin restorations with preheated resins and RC (resinous cement). *Indicates significant differences between both groups (p < 0.05) (B ).
Fig. 5 Images obtained with confocal microscopy of the penetration of rhodamine in restorations cemented with resinous cement in the vestibular wall (A ), cavity floor (B) , and palatine wall (C ), with PR in the vestibular wall (D ), cavity floor (E) , and palatine wall (F ).
Microtensile Bond Strength Test
Microtensile bond-strength values were lower in the restorations cemented with PR (144.49 N/cm3 ) and higher in those cemented with RC (278.75 N/cm3 ), with a statistically significant difference between the two groups (p < 0.05; [Fig. 4B ]).
Discussion
This study aimed to show that the use of PR as a cementing agent of indirect composite restorations in Class II cavities of premolars improves marginal sealing and therefore decreases microfiltration. Upon analyzing the results obtained in this study, it was observed that microfiltration was not eliminated in either of the two cements evaluated. The results showed that there was no significant difference in microfiltration in Class II cavities using PR or RC (resinous cement); however, the values obtained from microfiltration were lower for PR than for RC (resinous cement), while the micrographs obtained with SEM revealed better sealing and adaptation utilizing PR. The composite restorations probably settled better with PR due to the degree of fluidity of the material, improving the adaptation and thus the marginal sealing.
Studies have shown that RC (resinous cement) exhibited lower values of microfiltration than conventional cementing systems in both enamel and in dentin,[15 ]
[16 ] and insufficient scientific evidence has been reported on the effect of the use of PR on the marginal sealing and adhesive force of a composite to dentin restorations. Wagner et al[17 ] demonstrated significantly less microleakage at the cervical margin of Class II restorations with preheated composites, while Goulart et al[18 ] concluded that preheating composite resin for luting procedures may not improve the seal.
In indirect restorations of ceramics or in the composite values of marginal discrepancy ranging from 48 to 219 μm, it is recommended that the marginal adaptation of inlays should be less than 100 μm[19 ]; in our study, values less than 100 μm were obtained with an average value of 47.7 μm with PR and 8 of 4.4 μm for RC (resinous cement). It is noteworthy that the marginal discrepancy values are enhanced with the viscosity of cement and excess cement depending on the geometry of the cavity, and that there is a possibility that the marginal discrepancy values may be increased after the cementing protocol, the latter attributed to the increase of hydraulic pressure of the resin luting cement.[20 ]
On the other hand, the temperature of the materials has been shown to be a factor at room temperature or higher than the temperature of the human body[21 ]; preheating the resins to 60°C increases the conversion of monomers by increasing molecular mobility. Compounds with higher conversion have greater crosslinking and the free space of the polymers is reduced, improving their mechanical properties.[22 ]
[23 ]
[24 ] In this study, the PR was preheated to 55°C, a factor against the elapsed time of the isothermal condition to be placed in the syringe to inject the material, causing a temperature reduction to 50% after 2 minutes.[25 ] The RC (resinous cement) evaluated in this study was employed at room temperature, and a temperature reduction was not possible. The best temperature to cement the materials remains controversial, as studies have shown that cements at different temperatures did not exert significant effects on the marginal gap widths of the restorations,[26 ] and that preheating the light-curing only composites allows the materials to reach an optimal degree of conversion.[27 ] That is, the temperature does not influence the formation of the marginal gap, but it does exert an influence the fluidity of the material. It is important to note that the temperature increase should not affect the pulp tissue, and previous findings have demonstrated that an increase in the composite resin temperature to between 54°and 60°C does not significantly change the intrapulpar temperatures.[28 ]
Effective adhesion in enamel and dentin comprises an associated factor in the microtensile adhesion strength and in reducing the marginal microfiltration of indirect composite restorations. Studies have shown that the cervical enamel/dentin and composite resin interface are more vulnerable to microleakage.[28 ] In this study, analysis of the bond interface was observed in the SEM, and the PR group was observed to possess a hybrid layer after following the adhesion protocol. For RC (resinous cement), no prior treatment of the adhesive system is needed, and they also have the option of being utilized with conventional engraving. The results observed in the micrographs in this study revealed that the hybrid layer did not form, and adhesive failure is evident by the formation of gaps in the seal. In this study, the microtensile adhesion force of indirect composite restorations using PR as a cementing agent was lower than that of RC (resinous cement), possibly due to the composition and properties of RC (resinous cement) compared with PR. However, there remains controversy concerning what type of cement system has the best adhesion values in the cementation of partial adhesive composite restorations. Hepburn et al[29 ] recommend PR as a cementing agent, despite that the adhesive cementing systems clinically demonstrate an acceptable marginal discrepancy. In the case of veneer cementation, the use of preheated resinous cements has not shown greater volumetric polymerization shrinkage than the veneer cements; contrariwise, the film’s thickness has been less than that of the cement veneer when using the cementing agents of preheated fluid resins.[30 ]
Indirect adhesive restorations in resin are an economical option compared with other materials and are indicated when a proximal wall is missing, as in Class II cavities. The technique and the cementing agent are responsible for the volumetric contraction by polymerization and the thickness of the cement film,[27 ] and the composite selection impacts its response to preheating and the viscosity and thickness of the film.[29 ] Marginal gaps cause microfiltration, which is the main cause of the failure of a restorative treatment.[30 ] It is essential not to risk the formation of marginal gaps due to an inappropriate combination of the restorative material with the technique and cementing material. From a clinical perspective, the results of the present study show that PR is a luting agent for restorations of inlay-type composites in Class II cavities, and the possible advantages of its clinical use include the ease of removing excess material due to its fluidity in the walls of the cavity. Future studies will be required to evaluate the biological or clinical behavior in vivo of PR in the oral cavity.[31 ]
[32 ]
The limitations of this in vitro model are related to the differences between room temperature and mouth temperature, a discrepancy of 40 µm has been reported in the impression material at room temperature compared with that at mouth temperature by impression polymerization,[33 ] as well as the decrease in the temperature of the PR after removal from the heating device and the time elapsed for placing the PR into the in vitro model compared with the mouth temperature.[34 ] These conditions must be taken into account when the results obtained in this study are interpreted under clinical conditions.
Conclusion
PR are a cementing agent option for indirect resin restorations in Class II cavities in premolars; however, a limitation of this in vitro study is that it found no statistically significant difference in the degree of microfiltration using PR or RC, but in spite of that, better sealing and adaptation of restorations was observed using PR. The microtensile adhesion force between dentin and resin restoration is increased when cemented with a RC.