Permanent External Biliary Catheter: A Difficult Problem Managed by Rescue Technique of Hepatico-cholecysto-gastrostomy
Abstract
Percutaneous biliary drainage is commonly performed procedure after failure of ERCP in patients with biliary obstruction. Failure to internalization can lead to permanent external catheter. In the present case, problem of external biliary catheter was solved with hepaticocholecystogastrostomy. Guidewire from the external drain site could not be passed across the stricture, instead it was entering in the gall bladder. This was used as an opportunity to internalize the catheter. First EUS guided cholecystogastrostomy was performed, followed by placement of stent between right biliary system and the stomach, through the cholecystogastrostomy stent. This led to drainage of right biliary system into the stomach, and the external catheter could be removed.
#
External biliary drainage, a salvage procedure after failure of endoscopic retrograde cholangiopancreatography (ERCP), is associated with risk of permanent external biliary catheter. Permanent external biliary catheter is a troublesome situation and leads to deterioration in quality of life. A 70-year-old male presented with pruritus and jaundice. Imaging was suggestive of obstruction due to mass lesion at liver hilum, suggesting diagnosis of cholangiocarcinoma. During ERCP, wire could not be negotiated across the stricture; hence, rescue percutaneous transluminal biliary drainage (PTBD) was done. PTBD catheter could not be internalized because of non-negotiable stricture. As the guidewire from the PTBD site was repeatedly entering the gall bladder, hepaticocholecystogastrostomy was performed to internalize the PTBD catheter. PTBD catheter was first passed into collapsed gall bladder lumen, followed by saline infusion, leading to adequate distension of gall bladder ([Fig. 1a]). Endoscopic ultrasound (EUS)-guided cholecystogastrostomy was done using 15 mm × 10 mm lumen-apposing stent (Hot axios, Boston scientific, Marlborough, USA) ([Fig. 1b]); through the metal stent, 10Fr, 5 cm double pigtail plastic stent (C-Flex, Boston Scientific, Spencer, USA) was placed. Next day, from the PTBD site, guidewire was negotiated from right hepatic duct (RHD), across the gall bladder, through the cholecystogastrostomy stent into the gastric lumen ([Fig. 2a]), followed by self-expandable metallic stent (SEMS) placement (10 mm, 8 cm, Boston Scientific, Natick, MA, USA) ([Fig. 2b]) through the transhepatic route, connecting RHD to gastric lumen. PTBD catheter was removed next day, and further clinical course was uneventful. Failure to internalize the catheter is a common problem with PTBD.[1] [2] Various techniques[3] have been used to internalize the external catheter. Law et al[3] reported a case where EUS-guided hepaticogastrostomy was performed to internalize the left-sided PTBD catheter. In the present case, PTBD was done on right biliary system; hence, EUS guided hepaticogastrostomy was not possible. As the guidewire from the PTBD site was entering in gall bladder lumen, this was used as an opportunity to internalize the external biliary catheter.




Vikas Singla |
Writing the manuscript |
Ajit Kumar Yadav |
Collection of all the images and writing of manuscript |
Anil Arora |
Designing the work and writing the manuscript |
Arun Gupta |
Revision of manuscript |
#
Conflicts of Interest
None declared.
Authors Contribution
None.
-
References
- 1 Laméris JS, Stoker J, Nijs HG. et al. Malignant biliary obstruction: percutaneous use of self-expandable stents. Radiology 1991; 179 (03) 703-707
- 2 Piñol V, Castells A, Bordas JM. et al. Percutaneous self-expanding metal stents versus endoscopic polyethylene endoprostheses for treating malignant biliary obstruction: randomized clinical trial. Radiology 2002; 225 (01) 27-34
- 3 Law R, Sanchez-Ocana Hernandez R, de la Serna-Higuera C, Perez-Miranda M. EUS-guided biliary drainage for internalization of percutaneous transhepatic biliary drainage. VideoGIE 2017; 2 (11) 301-302
Address for correspondence
Publikationsverlauf
Artikel online veröffentlicht:
22. Januar 2021
© 2020. Society of Gastrointestinal Endoscopy of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
Thieme Medical and Scientific Publishers Private Ltd.
A-12, Second Floor, Sector -2, NOIDA -201301, India
-
References
- 1 Laméris JS, Stoker J, Nijs HG. et al. Malignant biliary obstruction: percutaneous use of self-expandable stents. Radiology 1991; 179 (03) 703-707
- 2 Piñol V, Castells A, Bordas JM. et al. Percutaneous self-expanding metal stents versus endoscopic polyethylene endoprostheses for treating malignant biliary obstruction: randomized clinical trial. Radiology 2002; 225 (01) 27-34
- 3 Law R, Sanchez-Ocana Hernandez R, de la Serna-Higuera C, Perez-Miranda M. EUS-guided biliary drainage for internalization of percutaneous transhepatic biliary drainage. VideoGIE 2017; 2 (11) 301-302