Keywords radioulnar joint - kinematics - ulnar variance - DRUJ - center of rotation
The distal radioulnar joint (DRUJ) plays a critical role for both load-bearing and motion of the upper extremity.[1 ]
[2 ] Ulnar variance (UV), the relative distal-proximal position of the distal ulna with respect to the radius, is often assessed to evaluate the etiology of wrist pain. Positive UV has been associated with ulnocarpal impaction syndrome and central tears of the triangular fibrocartilage complex (TFCC), while negative UV has been linked to Kienböck disease.[3 ]
[4 ]
[5 ]
[6 ] Additionally, the load seen across the ulnocarpal joint varies with even slight changes in UV. In a cadaveric study, Palmer and Werner demonstrated that a 2.5 mm change in UV decreases the load at the ulnocarpal joint from 18 to 4% when the ulna is shortened, but increases from 18 to 42% when the ulna is lengthened.[7 ]
Pathology involving the DRUJ often leads to pain and instability, which in severe cases- may require surgical interventions, such as ligament repair or reconstruction, resection, fusion, and, more recently, joint replacement.[8 ]
[9 ]
[10 ]
[11 ]
[12 ]
[13 ] Successful joint arthroplasty designs in shoulder, hip, and knee have shown the importance of implant design to reproduce healthy joint kinematics.[14 ]
[15 ]
[16 ]
[17 ] Biomechanical studies of the healthy DRUJ have reported that the location of the center of rotation (COR) is not fixed during forearm pronosupination[18 ]
[19 ] and that it moves volarly and ulnarly with elbow extension.[20 ] However, linked DRUJ implants that replace the sigmoid notch and ulnar head often employ a ball-and-socket design[8 ]
[11 ]
[12 ] which has a fixed COR at the center of the replacement ulnar head. Current DRUJ replacement provides pain relief and has an encouraging success rate, but it also suffers from a high complication rate (35% in 8 years) including periprosthetic fractures or continued instability after the surgery.[8 ]
[21 ] Although the reasons for complications are highly debated, abnormal kinematics may lead to increased implant-bone stress. Therefore, accurate in vivo evaluation of COR movement could help us to better understand normal kinematics and may help advance implant designs.
Although previous studies have demonstrated the change in UV[22 ]
[23 ]
[24 ] and COR[19 ]
[25 ] at different forearm rotation angles, they have not assessed their continuous changes throughout in vivo forearm pronation-supination (PS). Biplanar videoradiography (BVR) is an imaging technique that is used for computing the in vivo motion of other joints with high accuracy.[26 ]
[27 ]
[28 ]
[29 ]
[30 ]
[31 ]
[32 ]
[33 ] Thus, in this study, we used a BVR system to evaluate the mechanism of motion of DRUJ by analyzing specifically (1) UV and (2) COR during active pronosupination. We hypothesized that UV would be most positive at full pronation and that it would reduce as the forearm rotates towards full supination, where it would reach its minimum value. We also hypothesized that the COR is not stationary throughout pronosupination.
Methods
Subjects and In Vivo Imaging
Nine subjects (eight females, eight right-hand dominant, 56.9 ± 5.5 years) with no history of wrist or hand pathology were enrolled after Institutional Review Board approval as part of a larger study on wrist and forearm kinematics.[34 ] Computed tomography (CT) scans (Lightspeed 16, GE Medical, Milwaukee, WI) were acquired of the distal forearm, wrist, and hand with tube settings of 80 kVp and 80 mA, and three-dimensional (3D) image resolution of 0.39 × 0.39 × 0.625 mm3 . The radius and ulna were semiautomatically segmented using commercially available medical image processing software (Mimics v19, Materialise NV, Leuven, BE), using a gradient-based algorithm.[35 ] The segmented portions of the images reflecting the bones were exported as CT image volumes containing the attenuation values for further processing in BVR, and they were also exported as 3D surface models for kinematics analysis.
Experimental Setup
BVR acquisition was performed at the X-ray Reconstruction of Moving Morphology (XROMM) facility at Brown University ([Fig. 1 ]). The XROMM system consists of two Varian Medical Systems Model G-1086 X-ray tubes (Palo Alto, CA), two EMD Technologies model EPS 45 to 80 pulsed X-ray generators (Saint-Eustache, Quebec, QC), two 40-cm Dunlee (Aurora, IL) image intensifiers, and two Phantom v10 high-speed video cameras (Vision Research, Wayne, NJ). In this experiment, the angle between sources was 110 degrees, and the source-to-image distance was set at 130 cm. X-ray tube settings were adjusted between 68 and 75 kV and 80 mA, along with a continuous capture rate of 200 Hz and a shutter speed of 500 µs. The X-ray systems were calibrated, and radiographs were undistorted in XMALab software (Brown University, Providence, RI), using a previously described methodology.[36 ]
[37 ]
Fig. 1 The biplane videoradiography experimental setup. The orientation between sources was 110 degrees, and the source-to-hand distance was approximately 90 cm. A doorknob device was affixed to the trestle and subjects' wrist joint was at the center of the field-of-view of the X-ray sources.
Prior to the in vivo experiment, the rotational and translational accuracies of model-based BVR tracking for the DRUJ were assessed using an experimental setup that has been described previously.[28 ] Briefly, accuracy was determined in a study involving five forearms from four cadavers (two females, three right and one both sides, 70.5 ± 13.2 years). DRUJ motion was simultaneously calculated using eight motion capture cameras (gold-standard) and the BVR system during pronation and supination tasks. DRUJ kinematics and UV were computed as described in the next section. Overall, the accuracy of calculating the position and orientation of DRUJ was less than 1 degree and 1 mm, and the accuracy of computing the UV throughout pronosupination of the forearm was between −0.5 and 0.7 mm.
Each study participant performed active forearm pronation and supination using a custom-designed T-handle doorknob fixture. The doorknob fixture was fabricated from a plastic shovel handle with two sizes to accommodate different sizes of hands. Subjects started the tasks from a functional neutral position (i.e., holding pose) and performed two repetitions of pronation and supination, after they were coached and practiced reaching their maximum pronation or supination rotation rates as quickly as possible. To minimize the radiation exposure to the subjects, each direction of motion was limited to 2 seconds (i.e., 400 radiographic images) recording. The mean total effective radiation dosage of these two tasks and the CT acquisition was 47 mrem, equivalent to 28 days of background radiation in the United States.[38 ]
Data Processing
Radial and ulnar coordinate systems (CS) were defined from the surface bone models using their anatomical landmarks, as previously described ([Fig. 2 ]).[35 ]
[39 ]
[40 ] Briefly, the ulnar CS was defined with its x-axis along the ulnar shaft (positive proximally), and y-axis directed toward the ulnar notch but projected on the distal surface (positive radially). The origin was defined as the intersection of x-axis and the distal surface of the ulna (approximately at ulnar fovea). The radial CS's x-axis was defined in the direction of the radial shaft, and y-axis was toward the radial styloid projected to the articular surface of the radius with scaphoid.
Fig. 2 The coordinate systems of the radius and ulna in volar view of the ulna. x-axis (directed proximally), y-axis (directed radially), and z-axis (directed volarly) are shown for both bones. The ulnar variance was defined as the proximal-distal distance between the ulna fovea (origin of the ulnar coordinate system) to the sigmoid notch of the radius at the neutral pose. In this figure, the ulnar variance is negative.
DRUJ motion was calculated by tracking the radius and ulna in the videoradiographs using open-source markerless 2D to 3D image registration software, as described previously (Autoscoper, Brown University, https://simtk.org/projects/autoscoper ).[27 ]
[28 ] Briefly, digitally reconstructed radiographs (DRRs) were generated from the segmented CT volume images using a ray-casting approach, and both radius and ulna were tracked in the calibrated BVR space ([Fig. 3 ]). Tracking was accomplished by minimizing a normalized cross-correlation cost function between the DRRs and the radiographs using the particle swarm optimization algorithm.[41 ] The kinematic transformation matrices of the tracked bones were then transformed to their anatomical CS, and the relative position of radius in ulnar CS was calculated.
Fig. 3 Examples of tracked radius and ulna for one subject overlaid on one of the radiographs in the functional neutral position, mid- and full pronation (25 and 50 degrees), and mid- and full supination (30 and 60 degrees). The highlighted sections are the digitally reconstructed radiographs of the bones after tracking and optimization process. The features of the bones in the radiographs are enhanced using the Sobel and intensity image filters.
Helical axis of motion (HAM) parameters[42 ] were calculated to describe the kinematics as the relative motion of radius CS in ulnar CS, with respect to the neutral pose. The HAM rotation was decomposed in the ulnar CS using the HAM screw axis, and the pronation (positive) and supination (negative) of forearm were calculated. The neutral pose was defined when PS was zero. UV was defined as the relative position of the ulnar fovea (as a constant point fixed to the ulnar head) with respect to the distal margin of the sigmoid notch on the radius ([Fig. 2 ]). The COR location was defined as the intersection of the unique screw axis defined by HAM with the ulnar distal surface (yz-plane). The UV at the neutral pose for each subject was set to zero (0) to standardize changes as a function of PS.
Statistical Analysis
The full motion arc of the DRUJ and the dynamic behavior of UV were evaluated for all subjects. A generalized linear model was used to describe the relationship between the change in UV and PS (UV = p1
× PS2 + p2
× PS), where p1
and p2
were coefficients that were optimized using linear regression. Adjusted R
2 , and root-mean-square-error (RMSE) were calculated to define the robustness of the model, and 95% confidence intervals (CIs) were computed to describe the UV changes. The same model was also applied to the data for each individual to assure the robustness of the model in each subject. COR locations at each degree of PS were averaged across all subjects to demonstrate the dynamic change in the COR location as the forearm pronates and supinates.
Results
Average forearm pronation for the subjects we studied was 59.7 ± 11.8 degrees (range: 42.5–76.7 degrees) and average supination was 72.2 ± 11.1 degrees (55.3–92.1 degrees), for a total forearm pronosupination ROM of 131.9 ± 4.7 degrees (124.5–140.6 degrees). At the neutral position, UV was −1.6 ± 1.6 mm, while it was +1.3 ± 1.7 mm in maximum pronation and −1.8 ± 1.6 mm in maximum supination ([Table 1 ]).
Table 1
Maximum pronation and supination of the distal radioulnar joint during active motion, and associated ulnar variance at the neutral position and maximum pronation-supination for all subjects. Note that the most negative UV did not occur at maximum supination (see [Fig. 4 ])
Subjects
Ulnar variance at neutral (mm)
Maximum pronation (degrees)
Ulnar variance at maximum pronation (mm)
Maximum supination (degrees)
Ulnar variance at maximum supination (mm)
S1
−1.8
61.0
1.4
67.6
−3.0
S2
−0.8
43.1
1.7
92.9
−1.3
S3
−2.5
57.6
0.1
75.8
−2.1
S4
−2.1
73.3
1.7
54.8
−2.8
S5
−4.1
76.6
−1.5
64.3
−3.6
S6
−1.9
58.8
1.2
75.6
−2.4
S7
−1.7
48.9
1.1
82.0
−1.4
S8
−1.2
71.5
0.8
63.3
−1.8
S9
2.0
52.0
5.1
72.8
1.9
Mean
(SD)
−1.6
(1.6)
60.3
(11.5)
1.3
(1.7)
72.1
(11.3)
−1.8
(1.6)
Note: Ulnar variance was negative for all subjects except one, and ulnar variance at the maximum supination was approximately equal to its value at the neutral pose.
UV changed nonlinearly with pronosupination of the forearm ([Fig. 4 ]). The change in UV was the most positive at full pronation (2.9–5.2 mm 95% CI, p < 0.001), but decreased during supination, with the lowest UV (−1.8 to 0.5 mm) noted at mid-supination (approximately 38.0 degrees). Interestingly, the lowest UV was observed at mid-supination, and it increased slightly from mid-supination to full supination for all subjects. This behavior was modeled as a second-degree polynomial with an average (95% CI) p
1 of 0.00033 (0.00032, 0.00034), and p
2 of 0.0276 (0.0273, 0.0278). The fitted equation had an adjusted R
2 of 0.85, and RMSE of 0.60 mm. The second order polynomial models fit the individual subjects UV values well with an adjusted R
2 that ranged from 0.85 to 0.99 and RMSEs that were less than 0.59 mm.
Fig. 4 The change in ulnar variance (UV) from its value at the neutral position was nonlinear relative to forearm pronosupination. The most negative UV was noted at an average of 38.0 degrees of supination. The solid line is demonstrating the fitted model, and shaded area are demonstrating its 95% confidence interval.
The COR was located 0.5 ± 1.8 mm ulnarly and 0.6 ± 0.8 mm volarly from the ulnar fovea in maximum pronation (p > 0.05), while in maximum supination the COR was located 0.2 ± 0.6 mm radially and 2.0 ± 0.5 mm volarly from the fovea ([Figs. 5 ] and [6 ]). The dynamic nature of the shift in COR was observed from the neutral pose to maximum pronation, when the COR significantly moved volarly (p < 0.0001). There was no significant radial-ulnar translation for the COR (p > 0.05).
Fig. 5 Center of rotation (COR) moved volarly in supination, but it was stationary throughout pronation. The solid lines demonstrate the average COR location at every 2 degrees of pronation or supination, and the dashed lines demonstrate the standard deviation.
Fig. 6 Center of rotation moved volarly for eight (out of nine) participants from maximum pronation to maximum supination. Each arrow is directed from maximum pronation to maximum supination.
Discussion
Understanding how UV and COR change as the forearm pronates and supinates could help improve diagnosis and treatment strategies. In this study we used an accurate in vivo BVR technique and demonstrated the continuous change of UV during pronosupination from its most positive value at full pronation to its minimum occurring at approximately 38 degrees of supination, instead of full supination. Previous reports have demonstrated that UV decreases as the forearm goes from pronation to supination,[22 ]
[43 ] but this study is the first in vivo study to demonstrate the nonlinear relationship of these changes. We also demonstrated that the nature of COR is dynamic in supination.
Clinically, the finding that UV is the most negative at about half supination has implications in immobilization following stabilization procedures for the DRUJ or treatments of TFCC tears by arthroscopic or open means. Traditionally, immobilization has been in long arm splints with the forearm fully supinated; it stands to reason, based on our findings, that optimal immobilization of rotation following reconstructive procedures may be best at 40 to 45 degrees of supination to reduce DRUJ/TFCC stress.
By investigating the continuous pattern of change in UV, we provided an equation that could be useful in standardizing UV measures. Although a standard methodology for measuring UV exists,[44 ] the literature varies with regard to wrist and forearm position when radiographically assessing the UV,[22 ] which can directly impact the measurement.[20 ]
[23 ]
[24 ] We calculated the UV at the neutral forearm rotation pose and then evaluated the changes seen in the UV during PS compared with the neutral. The nonlinear behavior of UV could be informed by the previously described piston-like motion of the radius on the ulna.[1 ] We believe that the tilt on radial head and the inherent geometrical constraint of the proximal radioulnar joint are causing the radius to cross the ulna in a triangle-like form, resulting in this nonlinear pattern and producing positive UV. This nonlinear pattern might also correspond to how ulna “seats” into the sigmoid notch in full supination, and the fact that extensor carpi ulnaris is straight and dorsal above the ulna in this position.
Earlier studies have evaluated UV at only discreet postures, and they have been prone to errors due to the subjective measurement variations among the operators. However, in this study UV was measured continuously and accurately using objective metrics from 3D models for each subject. Previously, Epner et al studied seven cadaveric wrists and demonstrated that the UV becomes 1 mm more negative when the forearm rotates from pronation to supination.[22 ] However, the range of this change was between 0 and 2.1 mm leading to an inability to make conclusive statements. Jung et al studied 120 radiographs of healthy wrists in a power grip posture and found an overall weak linear relationship (R
2 = 0.07) between UV and forearm pronosupination, decreasing from +1.5 ± 1.6 mm in full pronation to +0.9 ± 1.5 mm in full supination. However, the authors only measured UV at maximum pronation and supination, and not continuously for each subject as we did in this study. Therefore, they were not able to detect a meaningful relationship between UV and pronosupination of individuals to understand the actual nonlinear relationship.[23 ] Lastly, Yeh et al studied radiographs of the forearms of 15 subjects and found a significant difference between the UV measured in pronation and neutral, but not neutral and supination, possibly due to the inaccuracies of UV measurement manually from the radiographs.[24 ] However, our submillimeter accuracy in measuring UV enabled us to demonstrate a 3.1 ± 1.6 mm change in UV from maximum pronation to maximum supination.
The COR location of DRUJ is not stationary, and as a previous study has described, it changes even with elbow flexion.[20 ] In this study we also demonstrated that the DRUJ COR changes during forearm rotation. The dynamic COR and the polynomial behavior of the UV at the DRUJ suggests that the DRUJ is moving during PS. Linked DRUJ replacement implants designed to stabilize an unstable or arthritic joint transform the DRUJ into a ball and socket articulation,[8 ] only allowing pure rotation and not the volar-dorsal translation that we found in this study. Although short-term outcomes have been promising,[8 ]
[45 ] altered kinematics of the DRUJ may lead to increased bone-implant stress and loosening or implant fracture in the long-term. Incorporating the COR and the UV translation into articulation design might help create a truly anatomical joint replacement.
There were some limitations to this study. Although the subjects were guided to hold their elbow in 90 degrees flexion, we were unable to control the exact degree of elbow flexion while the subjects performed the tasks of forearm rotation. Previous studies have mentioned the effect of elbow flexion on the UV and COR,[20 ] but these changes are only significant when elbow moves from fully flexed position to fully extension. Thus, we believe our results are largely unaffected by this variation. Additionally, we were limited by the relatively small sample size and the homogenous nature of the subject's age and sex. Measured from the posteroanterior radiograph,[46 ] total configuration of the DRUJ of all of our participants was type II (oblique) and within range of 7.4 to 17.6 degrees. Although for the subjects included in the study a consistent pattern was noted for the UV and the COR changes, a larger sample size may provide an argument for a generalizable dataset. The shape of the sigmoid notch also varies in populations,[46 ] and large databases might be helpful in associating these variations to the COR changes.
In this study, we evaluated the motion of DRUJ by specifically observing UV and COR changes seen with forearm rotation. Our measurements of UV demonstrated a consistent, nonlinear behavior among all subjects, and a model was developed to standardize and calculate UV as a factor of the forearm rotation. COR did not change significantly in pronation, but it translated volarly during supinations.