Introduction
Endodontic retreatment in mandibular molars poses greater difficulty owing to the curvature in molar mesial roots.[1 ]
[2 ] Use of nickel–titanium (NiTi) instruments with larger diameter in curved root canals can lead to deviations and instrument fracture, because of low flexibility[3 ] and cyclic fatigue resistance.[4 ] However, heat treatments have been developed to optimize the mechanical properties of NiTi instruments.[5 ]
[6 ] Controlled memory (CM) heat treatment promotes an NiTi alloy martensitic phase at room temperature,[7 ] providing greater flexibility and resistance to cyclic fatigue,[8 ] thus enabling apical enlargement in curved root canals.[9 ]
Although mechanized NiTi instruments have been used in endodontic retreatments because of their safety[10 ] and effectiveness in removing filling materials,[11 ]
[12 ]
[13 ]
[14 ] these materials cannot be fully removed from the root canal,[15 ]
[16 ]
[17 ]
[18 ]
[19 ]
[20 ]
[21 ]
[22 ] especially in the apical third of curved root canals.[23 ] Apical enlargement can improve removal of filling materials[13 ]; however, an increase in the apical preparation of curved root canals using instruments with larger diameter may result in excessive dentin removal.[24 ]
ProDesign Logic (PDL) and ProDesign S (PDS) (Easy Equipamentos Odontológicos; Belo Horizonte, MG, Brazil) are NiTi rotary instruments with CM heat treatment. The PDL 50/.01 file has a large tip size and minimal taper, which has been proposed to perform apical enlargement in endodontic retreatments.[13 ] Use of PDL size 50/.01 have been found to significantly decrease the amount of filling material in the apical third of curved lateral incisors.[13 ] However, there are no studies to date that have evaluated the increase in root canal volume promoted by the PDL 50/.01 instrument in retreating curved root canals. In addition, the cyclic fatigue resistance of PDL 50/.01 has not yet been evaluated.
The aim of this study was to use microcomputed tomography (micro-CT) to evaluate the effect of apical enlargement with the PDL 50/.01 instrument in the retreatment of curved mesial root canals of mandibular molars. The cyclic fatigue resistance of the NiTi rotary PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments was also evaluated. The first and second null hypotheses were that using a PDL 50/.01 instrument after retreatment with PDL 35/.05 would not decrease the amount of remaining filling material, and would not change the root canal volume, respectively. The third null hypothesis was that there would be no difference in the cyclic fatigue resistance among the NiTi rotary instruments evaluated.
Materials and Methods
Sample Size Calculation
The tests were performed with a specific G* Power software program (3.1.7 for Windows, Heinrich Heine, Universität Dusseldorf, Germany). The t-test for two dependent groups was used with an alpha type error of 0.05 and beta power of 0.95 for all the variables. Previous studies were used to determine the specific effect size for the amount of remaining filling material (2.348)[12 ] and root canal volumes (1.209).[9 ] A total of 12 specimens were indicated as the ideal size required.
Specimen Selection
After approval of the study by the Institutional Ethics Committee (64736116.4.0000.5416), 12 human mandibular first and second molars were selected. The inclusion criteria included two independent mesial root canals according to Vertucci’s type IV classification,[25 ] angle of curvature between 25°and 35°,[1 ] and radius of curvature smaller than 10 mm,[26 ] as well as complete apical formation, and absence of root fractures, calcifications or internal resorptions. The specimens were selected by a digital radiography system (RVG 6100; Kodak Dental Systems, NY, USA) and micro-CT (SkyScan 1176; Bruker-micro-CT, Kontich, Belgium) used at 35-µm voxel size, and the following settings were considered: copper and aluminum filter, exposure time of 87 ms, average of 3 frames, 180°rotation, 0.5 rotation step, 80 kV, and 300 µA. A total of 12 roots were selected, totaling 24 root canals, including the mesiobuccal and the mesiolingual canals of each root. The root length was standardized at 18 mm, with a tolerance of ± 1 mm. The specimens were embedded in silicone (Oranwash; Zhermack, Badia Polesine, Italy) to simulate the periodontal ligament. All the root canals were prepared, filled, and retreated using the same technique, to allow comparison of the variables before and after use of the PDL 50/.01.
Root Canal Preparation
Conventional access cavities were performed, and the root canals were explored with a size #10 K-file (Dentsply Sirona Endodontics; Ballaigues, Switzerland). The working length (WL) was established 1 mm short of the apical foramen. Preparation was performed using PDL 25/.01 operated by a VDW Silver (VDW GmbH; Munich, Germany) electric motor in rotary motion at a speed of 350 rpm and 1 Ncm torque, with in-and-out movements up to the WL. Then, PDL size 25/.06 was used at 600 rpm and 3 Ncm torque, as described above. Each root canal was irrigated with 5 mL of 2.5% sodium hypochlorite (NaOCl) (2.5 mL after use of each file). Final irrigation was performed with 2.5 mL EDTA under agitation for 3 minutes, and then irrigation using 5 mL of distilled water.
Root Canal Filling
The root canals were filled using the continuous wave of condensation technique. Tanari 25/.06 (Tanariman; Manacapuru, AM, Brazil) gutta-percha points were selected according to the tip size and taper measured by a profilometer (Profile Projector Nikon model 6C-2; Nikon, Tokyo, Japan). After radiographic evaluation was made of the selected gutta-percha point adaptation, the point was covered with AH Plus sealer (Dentsply DeTrey GmbH, Konstanz, Germany) and placed in the root canal with a size 25 Lentulo (Dentsply Maillefer, Ballaigues, Switzerland). The thermoplastic plugger from the Termo Pack II System (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) was used for plasticization, cutting and compaction of the gutta-percha within the apical root canal up to 3 mm of the WL. The thermal injector of the system was used to inject the warmed gutta-percha. Compaction was performed with NiTi condensers (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil). A radiograph was taken to determine the quality of the obturation. Coronal sealing was performed with Coltosol restorative material (Vigodent, Rio de Janeiro, RJ, Brazil), and the roots were kept in an incubator at a temperature of 37°C in 95% humidity for 7 days, to allow the sealer to set.
Root Canal Retreatment
A VDW Silver electric motor was used in rotary motion at 600 rpm and 3 Ncm torque. In-and-out movements were performed up to the WL. PDS 25/.08 was used to remove the filling from the cervical and middle thirds, and PDL 25/.06 was used to remove the filling from the apical third. The root canals were enlarged with PDL 35/.05 as described above. Each root canal was irrigated with 6 mL of 2.5% NaOCl (2 mL for each instrument). Final irrigation was performed as described in the preparation step.
Supplemental Cleaning Approach
The PDL 50/.01 was operated with a VDW Silver electric motor in rotary motion at a speed of 350 rpm and 1 Ncm torque, with in-and-out movements up to the WL. The root canals were irrigated with 2 mL of 2.5% NaOCl. Final irrigation was performed as previously described.
Micro-CT Scanning and Analysis
The roots were scanned using micro-CT before and after root canal retreatment, and after apical enlargement with PDL 50/.01. The scanning parameters were copper and aluminum filter, 90 kV, 278 mA energy, 180°rotation, 0.5 rotation step, average of 3 frames, and 8.74 µm voxel size. The images obtained were reconstructed using the NRecon software program (v.1.6.3; Bruker-micro-CT) and superimposed by geometric alignment in the Data Viewer software program (v.1.5.1; Bruker-micro-CT). Volumetric analysis was performed in all the root canals using a CTAn software program (v.1.14.4; Bruker-micro-CT) with a specific task list. Root canal volume and remaining filling material were quantified after the retreatment steps. The gray scale range, which is required to recognize each object under study, was determined in a density histogram by using the adaptive threshold method. Representative images were performed using the models obtained by the CTVox software program (v.3.2; Bruker-micro-CT). Evaluation was performed in the apical third and the cervical/middle thirds of the root canals. A value of approximately 9 mm was determined for the total length analysis, approximately 3 mm for the apical third, and 6 mm for the cervical/middle thirds.
Cyclic Fatigue Test
The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments was evaluated (n = 12). The static bending test was performed in a device simulating an artificial canal with a 60°angle and 5-mm radius of curvature ([Fig. 1 ]) The instruments were used at 300 rpm and 300 g/cm torque of continuous rotary motion, driven by a VDW Silver (VDW Silver, GmbH, Munich, Germany) electric motor. All instruments were rotated until fracture, and WD-40 synthetic oil (WD-40 Multipurpose Product, Brazil) was used to reduce friction. The time to failure was obtained in minutes.
Fig. 1 Representative image of the cyclic fatigue test.
The device used for the tests consisted of an iron base (50 × 30 cm) with a fixing support for the low-speed handpiece, in accordance with previous studies.[27 ]
[28 ] After the instruments had been coupled to the low-speed handpiece, the height of the support was adjusted, so that the instrument could be inserted into the artificial canal without causing stress, thus allowing free rotation. The curvature of the stainless-steel artificial canal was fitted into a cylinder guide made of the same material. A groove served as the guide path for the instrument, which remained curved and free to rotate. During the tests, the instruments were placed, so that 1 mm of the instrument tip protruded beyond the end of the artificial canal walls, to allow the tip to be visualized, and the moment of instrument fracture to be determined.
Statistical Analysis
All the data were analyzed with the GraphPad Prism 7.00 statistical software package (GraphPad Software, La Jolla, CA, USA). The data were submitted to the Shapiro–Wilk normality test. The paired t-test was used for comparison of the root canal retreatment before and after PDL size 50/.01 taper preparation. One-way ANOVA and Tukey tests were used to compare instruments for cyclic fatigue. The level of significance was set at 5% for all the analyses.
Results
Use of PDL 50/.01 decreased the remaining filling material and increased the root canal volume in the apical third (p < 0.05). ([Table 1 ]
[Table 2 ]
[Fig. 2 ]).The volume of the root canals was similar in the cervical/middle thirds before and after preparation with PDL 50/.01 (p > 0.05) ([Table 2 ]). PDL 50/.01 had higher cyclic fatigue resistance than PDS 25/.08, PDL 25/.06 and PDL 35/.05 (p < 0.05) ([Fig. 3 ]).
Table 1
Residual filling material (%) in the curved root canals before and after the use of PDL 50/.01 and the reduction of residual filling material (%) (mean and standard deviation)
Before PDL 50/.01
After PDL 50/.01
Reduction in residual filling material (%)
Abbreviations: PDL, ProDesign Logic; PDS, ProDesign S.
Note: Different lowercase letters on same line represent significant intragroup differences (p < 0.05).
Cervical/middle
9.876 ± 2.543a
9.289 ± 3.523a
5.97 ± 1.54
Apical
8.920 ± 3.230a
3.895 ± 1.897b
56.35 ± 9.76
Table 2
Root canal volume (mm3) in the curved root canals before and after the use of PDL 50/.01 and root canal volume increase (%) (mean and standard deviation)
Before PDL 50/.01
After PDL 50/.01
Volume increase
Abbreviations: PDL, ProDesign Logic; PDS, ProDesign S.
Note: Different lowercase letters on same line represent significant intragroup differences (p < 0.05).
Cervical/middle
3.952 ± 0.208a
4.001 ± 0.432a
1.23 ± 0.32
Apical
0.617 ± 0.105b
0.861 ± 0.092a
39.54 ± 4.87
Fig. 2 Three dimensional reconstructions and cross-sectional images of mesial root canals of mandibular molars after the steps of obturation, retreatment, and additional retreatment. Filling material is shown in white.
Fig. 3 Means and standard deviations of time up to instrument fracture. Different uppercase letters indicate a statistical intergroup difference (p < 0.05).
Discussion
Endodontic retreatment is the main option when endodontic treatment failure occurs.[29 ] However, failure during removal of the filling material may not allow disinfection of the root canal system.[12 ]
[16 ] The remaining filling material allows the reinfection of the root canal system, leading to the maintenance of periapical peridontitis.[30 ] Apical enlargement two sizes larger than the instrument used for root canal preparation is recommended to improve the removal of filling materials.[31 ] Therefore, in the present study, root canals were prepared up to size 25/.06 and were enlarged up to size 35/.05 during retreatment. However, corroborating previous investigations,[11 ]
[13 ]
[18 ] the present study showed a considerable percentage of filling material inside the root canals, with a mean of 9.87% and 8.92% in the cervical/middle and apical thirds, respectively.
The first null hypothesis was rejected, since the PDL 50/.01 instruments reduced 56.35% of the remaining filling material in the apical third of the curved mesial root canals of lower molars. Significant reduction in residual material at apical levels in curved root canals after additional apical enlargement is reported.[13 ]
[32 ] Removal of the remaining filling material probably occurred because greater apical enlargement increases the ability of the instrument to reach the root canal walls.[33 ] In addition, the increase in the volume of the apical third after using the PDL 50/.01 allows better cleaning of the root canal, favoring the effect of the irrigating solution,[34 ] and enhancing root canal disinfection.[35 ]
Apical enlargement may promote excessive removal of dentin, thus decreasing root strength.[24 ] Therefore, the current study assessed the volume of the root canals before and after retreatment. Our second null hypothesis was partially accepted, since the volume of the root canals was similar in the cervical/middle thirds before and after preparation using PDL 50/.01. This indicates that this instrument maintains dentin thickness in the danger zone of mandibular molars. The small taper of these instruments allows apical preparation with no dentinal removal in the cervical and middle thirds. The root canal preparation for retreatment using PDL 35/.05 involves a 0.55-mm diameter at 4 mm from the apical preparation. PDL 50/.01 taper has a diameter of 0.54 at 4 mm from the apical preparation; therefore, its effect occurs only in the apical third. In addition, the CM heat treatment of this instruments allows root canal enlargement of curved canals with no apical transportation.[9 ]
The fracture of mechanized NiTi instruments may cause a deleterious effect on root canal disinfection.[29 ] Cyclic fatigue fractures occur after repeated tension and compression forces on instruments submitted to motion in curved root canals.[36 ] The third null hypothesis of this study was rejected, since PDL 50/.01 showed higher cyclic fatigue resistance than PDL 25/.06, PDL 35/.05 and PDS 25/.08. The minimal taper (.01) of PDL size 50 presents less metallic volume than the other instruments evaluated. Instruments with a larger metal mass volume have lower flexural strength.[36 ] PDS and PDL instruments were found to have higher cyclic fatigue resistance than the HyFlex CM, Edge File, and Mtwo systems.[8 ]
The main limitation of this supplemental cleaning approach using PDL 50/.01 is that this instrument did not provide effective removal of the remaining filling in the cervical and middle thirds of the root canal. Hence, a suggested approach would be to associate the PDL 50/.01 with an effective supplemental cleaning process for the cervical and middle thirds. However, the significant decrease in the remaining filling material in the apical third promoted by PDL 50/.01 has clinical relevance, since cleaning of the apical third is a challenge in retreatment procedures.[23 ]
[37 ] The apical third of the canal is always more difficult to clean, an aspect worth pointing out, because it represents a critical infection zone prone to development and maintenance of apical periodontitis.[38 ]
Larger apical enlargement during retreatment procedures decreases the remaining filling material,[32 ] reducing endotoxin levels.[39 ] On the other hand, preparation of curved mesial root canals using larger diameter instruments may produce excessive dentin removal in the danger zone, reducing tooth resistance.[24 ] The present results have shown that apical enlargement with mechanized NiTi instruments having minimal taper, such as PDL 50/.01, seems to be effective in reducing the remaining filling material in the apical third of curved root canals of mandibular molars, with no additional dentin removal in the cervical and middle thirds. Moreover, a low risk of cyclic fatigue fracture was observed for this instrument. However, the protocol evaluated in the current study was not able to remove the filling material completely from the root canals.
Conclusions
The PDL 50/.01 instrument improved removal of filling material in the apical third when used as a supplemental procedure for retreatment of curved root canals, and it also proved safe in not promoting dentin removal in the cervical and middle thirds. In addition, PDL 50/.01 had high flexural resistance.