Int J Angiol 2022; 31(04): 267-272
DOI: 10.1055/s-0041-1729736
Original Article

The Potential of AFX Iliac Extension in Abdominal Aortic Aneurysms with High Iliac Tortuosity

Yuta Kikuchi
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
,
Norifumi Ohtani
2   Department of Cardiovascular Surgery, Sapporo Teishinkai Hospital, Sapporo, Hokkaido, Japan
,
Hiroyuki Kamiya
1   Department of Cardiovascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
› Author Affiliations

Abstract

Recently, endovascular aortic aneurysm repair (EVAR) is the most common surgery for abdominal aortic aneurysm (AAA). However, iliac limb complications of EVAR often cause problems in patients with high iliac tortuosity. There is no difference of rate of iliac limb complication among EVAR devices, such as Excluder, Endurant, and Zenith in high iliac tortuosity. But there has been not reported about AFX. We studied AFX iliac extension as it is the only stent graft with an endoskeletal framework. This study aimed to evaluate the AFX iliac extension patency in a case in vitro and to use it in seven cases of AAA with high iliac tortuosity. The silicon tube inserted in the AFX iliac extension was flexed at 30, 60, 90, and 120 degrees, and the lumen of the iliac extension was monitored using an underwater camera in the circulatory system. During the experiment, the Iwaki Bellows Pump (IWAKI CO., LTD., Tokyo, Japan) produced a pulsating flow. We used this in seven patients with AAA high iliac tortuosity cases between November 2018 and May 2019. If the silicon tube inserted in the AFX iliac extension was flexed at 60 and 120 degrees, the stent protruded into the lumen. However, the graft was dilated at all degrees. All seven patients with AFX iliac extension had no complications and a patent iliac artery. The AFX iliac extension can reduce iliac limb complications in cases of high iliac tortuosity.



Publication History

Article published online:
23 May 2021

© 2021. International College of Angiology. This article is published by Thieme.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Lee JH, Park KH. Self expandable stent application to prevent limb occlusion in external iliac artery during endovascular aneurysm repair. Ann Surg Treat Res 2016; 91 (03) 139-144
  • 2 Cochennec F, Becquemin JP, Desgranges P, Allaire E, Kobeiter H, Roudot-Thoraval F. Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. Eur J Vasc Endovasc Surg 2007; 34 (01) 59-65
  • 3 Maldonado TS, Rockman CB, Riles E. et al. Ischemic complications after endovascular abdominal aortic aneurysm repair. J Vasc Surg 2004; 40 (04) 703-709 , discussion 709–710
  • 4 Wyss TR, Dick F, Brown LC, Greenhalgh RM. The influence of thrombus, calcification, angulation, and tortuosity of attachment sites on the time to the first graft-related complication after endovascular aneurysm repair. J Vasc Surg 2011; 54 (04) 965-971
  • 5 Coulston J, Baigent A, Selvachandran H, Jones S, Torella F, Fisher R. The impact of endovascular aneurysm repair on aortoiliac tortuosity and its use as a predictor of iliac limb complications. J Vasc Surg 2014; 60 (03) 585-589
  • 6 Chaikof EL, Fillinger MF, Matsumura JS. et al. Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg 2002; 35 (05) 1061-1066
  • 7 Wolf YG, Tillich M, Lee WA, Rubin GD, Fogarty TJ, Zarins CK. Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg 2001; 34 (04) 594-599
  • 8 Abbruzzese TA, Kwolek CJ, Brewster DC. et al. Outcomes following endovascular abdominal aortic aneurysm repair (EVAR): an anatomic and device-specific analysis. J Vasc Surg 2008; 48 (01) 19-28
  • 9 Duffy JMN, Rolph R, Waltham M. Stent graft types for endovascular repair of abdominal aortic aneurysms. Cochrane Database Syst Rev 2015; 2015 (09) CD008447
  • 10 Kouvelos GN, Nana P, Bouris V. et al. Initial clinical experience with the Endologix AFX unibody stent graft system for treating patients with abdominal aortic aneurysms: a case controlled comparative study. Vasc Spec Int 2017; 33 (01) 16-21
  • 11 Jo E, Ahn S, Min SK, Mo H, Jae HJ, Hur S. Initial experience and potential advantages of AFX2 bifurcated endograft system: comparative case series. Vasc Spec Int 2019; 35 (04) 209-216
  • 12 Silingardi R, Sirignano P, Andreoli F, Mansour W, Migliari M, Speziale F. LIVE Study Collaborators. Unibody endograft using AFX 2 for less invasive and faster endovascular aortic repair: protocol for a multicenter nonrandomized study. JMIR Res Protoc 2020; 9 (04) e16959