Keywords anterior cruciate ligament - anterolateral ligament reconstruction - tunnel collision - knee
The anterior cruciate ligament (ACL) is frequently injured in the athletic populations. ACL reconstruction has been considered as a treatment for controlling anteroposterior and rotational stability.[1 ] Recently, the anterolateral ligament (ALL) has been reported as a secondary stabilizer to the ACL in several biomechanical studies.[2 ]
[3 ]
[4 ] The ALL also provides rotational control of the knee during the simulated pivot shift[2 ] and in resisting anterior tibial translation[4 ] and internal tibial rotation.[3 ] A cadaveric biomechanical study has suggested that ALL injury may contribute to residual internal rotation and a positive pivot shift following ACL reconstruction.[2 ] Preoperative ALL injury was associated with worse clinical outcomes after ACL reconstruction compared with isolated ACL injury.[5 ] Concomitant ACL and ALL reconstruction has been shown to reduce internal rotation and axial plane tibial translation compared with isolated ACL reconstruction for ACL- and ALL-deficient knees.[6 ] Moreover, combined ACL and ALL reconstruction has been reported as an effective technique for achieving a higher rate of return to preinjury sport levels,[7 ]
[8 ]
[9 ] reduction in graft failures,[8 ]
[9 ]
[10 ] and better knee stability[7 ]
[8 ]
[10 ] compared with isolated ACL reconstruction.
Although various techniques for ALL reconstruction have been reported,[11 ]
[12 ]
[13 ] the risk of collision with an ACL tunnel during drilling for the femoral ALL tunnel has been described.[11 ]
[14 ] Numerous studies have evaluated the risk of femoral tunnel collision between the ACL and the fibular collateral ligament (FCL)[15 ]
[16 ]
[17 ] for multiligament reconstruction; however, there have been few reports on femoral tunnel collisions in combined ACL and ALL reconstruction.[14 ]
[18 ] Furthermore, these studies on femoral tunnel collisions have evaluated single-bundle ACL and ALL reconstruction procedures[14 ]
[18 ] without assessing combined double-bundle ACL and ALL reconstruction. Although the superiority of double-bundle over single-bundle ACL reconstruction remains controversial, some reports have stated that double-bundle ACL reconstruction is superior in decreasing the risk of graft failures[19 ] and in providing better knee stability.[20 ]
[21 ] Therefore, it is important to establish procedures that aid in avoiding femoral tunnel collisions during combined double-bundle ACL and ALL reconstruction.
The purpose of this study was to investigate the various drilling procedures to avoid collisions between femoral ACL and ALL tunnels during combined double-bundle ACL and ALL reconstruction. We hypothesized that very specific ALL drilling angles would be necessary to ensure an optimal drilling procedure, in order to avoid collisions during combined reconstructions.
Materials and Methods
This study was approved by the institutional review board of the affiliated institutions.
Subjects
Nine cadaveric knees (four male and five female cadavers from a 2019 gross anatomy course) embalmed with formaldehyde were used for this study. All had intact cruciate ligaments, and none presented with macroscopic evidence of fractures, deformities, or joint contractures. The mean age of the subjects at the time of death was 81.4 ± 14.1 years (range: 67–105 years). Height and weight measurements were not available. The patella, patellar tendon, skin, subcutaneous tissue above the patella and patellar tendon, infrapatellar fat pad, and ACL were removed to expose the femoral footprint of the ACL. The footprint of the posterolateral (PL) and anteromedial (AM) bundles of the ACL was identified by referring to the native ACL footprint and a previous report on the ACL femoral footprint.[22 ]
ACL Drilling
A 2.4-mm diameter Kirschner wire (K-wire) was inserted through the anteromedial portal, which was situated in the medial position as much as possible without injuring the articular cartilages and menisci ([Fig. 1A ]). Previous studies have described the potential risks associated with ACL femoral drilling through the anteromedial portal (e.g., injury to the common peroneal nerve,[23 ]
[24 ] blowout of the posterior femoral cortex,[23 ]
[25 ]
[26 ] and short femoral tunnels[25 ]) and have recommended that the knee be flexed > 110° to decrease the risk of these complications.[23 ]
[24 ]
[25 ]
[26 ] Based on these reports, we evaluated the knees that were flexed 120° and 135° in this study. The K-wire was then inserted through the footprint of the PL bundle of the ACL with the knee flexed to 120° (PL120). The next K-wire was also inserted through the footprint of the PL bundle of the ACL with the knee flexed to 135° (PL135). The remaining two K-wires were both inserted through the footprint of the AM bundle of the ACL: one with the knee flexed to 120° (AM120) and the other with the knee flexed to 135° (AM135). A total of four K-wires were inserted through the ACL footprint, and the flexion angles of the knees were measured using a goniometer. The K-wires inserted in the knees flexed to 120° were pulled laterally out of the intra-articular space, so that when the knees were flexed to 135°, the subsequent K-wires could be inserted through the same points. After insertion of the four wires, the knee joint and the distal third of the femur were dissected free from all soft tissues ([Fig. 1B ]), and the femur was placed onto a wood block.
Fig. 1 Drilling procedure for the anterior cruciate ligament (ACL). (A ) For the anterior ACL drilling, a 2.4-mm-diameter Kirschner wire (K-wire) is inserted through the anteromedial portal, which is situated as much as possible in the medial and inferior position without injuries to the articular cartilages and menisci. (B ) After insertion of the four K-wires for ACL drillings, the knee joint and the distal third of the femur are dissected free from all soft tissues. The blue dot indicates the lateral epicondyle.
Distance from the ALL Footprint to the K-wire Outlet
The anterior-posterior and proximal-distal axes were defined as the lines perpendicular and parallel to the long axis of the femur, respectively.[17 ] The center of the ALL footprint was identified as the point 4.0 mm proximal and 6.0 mm posterior from the lateral epicondyles, based on previous anatomic and morphologic analyses (average ALL attachment: 2.7 mm proximal and 2.8 mm posterior to the FCL,[27 ] average FCL attachment: 1.4 mm proximal and 3.1 mm posterior to the lateral epicondyle).[28 ] Using a ruler, we measured the distance (in mm) from the center of the ALL footprint to the K-wire outlet on the lateral surface of the femur in each knee: (1) directly (point-to-point); (2) along the anterior-posterior axis (anterior direction); and (3) along the proximal-distal axis (proximal direction) ([Fig. 2A ]). Considering that the tunnels utilized for reconstruction grafts require K-wires with a diameter greater than 2.4 mm, the simulated distance (mm) was evaluated for the collision between ACL and ALL tunnels in the simulation of 4.0- and 5.0-mm diameter ACL and ALL drilling, respectively, using the measured distance (mm) as a reference parameter. The simulated distance was obtained using the following formula ([Fig. 2B ]):
Fig. 2 Distance from the anterolateral ligament (ALL) footprint to the Kirschner wire (K-wire) outlet. Anterior-posterior and proximal-distal axes are defined as the lines perpendicular and parallel to the long axis of the femur, respectively. (A ) Distance from the ALL footprint to the outlet point of the anterior cruciate ligament (ACL) The K-wire was measured on the lateral surface of the femur: 1) directly (point-to-point), 2) along the anterior-posterior axis (anterior direction), and 3) along the proximal-distal axis (proximal direction). (B ) The simulated distance (point-to-point) is evaluated for the collision between ACL and ALL tunnels in the simulation of 4.0- and 5.0-mm diameter ACL and ALL drilling, respectively, using the following formula: S
imulated distance = M
easured distance – 3.3.
S
imulated distance = M
easured distance – 3.3.
S
imulated distance < 0 signified collision between ACL and ALL tunnels on the lateral surface of the femur in the simulated reconstruction.
ALL Drilling
ALL femoral drilling was performed in both the coronal and axial planes. The 0° coronal line was defined as the line parallel to the distal condylar line of the femur ([Fig. 3A ]). The 0° axial line was defined as the line parallel to the posterior condylar line of the femur ([Fig. 3B ]). A 2.4-mm diameter K-wire was inserted through the ALL footprint at 0° (Cor0-ALL) and 30° coronal angles (Cor30-ALL) ([Fig. 3A ]). The ALL K-wire was made to collide with each inserted ACL K-wire by adjusting the axial angles in the Cor0-ALL and Cor30-ALL orientations. The axial angles (°) of ALL K-wires during collisions and the distances (D , mm) from the ALL footprint to the collision point were measured in each knee using a protractor and another K-wire of the same length, respectively ([Fig. 3B, C ]). Wood blocks configured into a cube or quadrangular prism to maintain the 0° and 30° coronal angles, respectively ([Fig. 4A. B ]) were used to standardize ALL drilling. The wood blocks enabled us to maintain the correct orientations during drilling and improved the accuracy of our axial angle measurement.[15 ]
Fig. 3 Drilling procedure for the anterolateral ligament (ALL) and simulation of no-collision angles. ALL drilling is performed in both the coronal and axial planes. (A ) The neutral (0°) coronal line is defined as the line parallel to the distal condylar line, and the Kirschner wire (K-wire) is inserted through the ALL footprint at 0° (Cor0-ALL) and 30° coronal angles (Cor30-ALL). (B ) The neutral (0°) axial line is defined as the line parallel to the posterior condylar line, and the axial angles (°) of ALL K-wires during collisions and the distances (D , mm) from the ALL footprint to the collision point are measured in the Cor0-ALL and Cor30-ALL orientations. (C ) This is the schema, which is an expanded form of the square area in [Fig 3B ] for the range of the simulated collision angles and no-collision angles in the simulation of 6.0-mm-diameter anterior cruciate ligament (ACL) overdrilling and 5.0-mm diameter ALL drilling. The range of the simulated collision angles was obtained using the following formula: (A
xial angle – θ) < S
imulated collision angle < (A
xial angle + θ), sin θ = (3.0 + 2.5) / (D + 1.2). The range outside the simulated collision angles is defined as the range of the simulated no-collision angles.
Fig. 4 Schematic representations of the wood model and the lateral face of a left knee. The two wood blocks are configured into a cube (A ) or quadrangular prism (B ) to maintain the required coronal angles at 0° (A ) and 30° (B ) during anterolateral ligament (ALL) drilling to improve the accuracy of our axial angle measurements.
Simulation of Collision Angle and Safe Zone in ALL Drilling
Considering that the tunnels utilized for reconstruction grafts require K-wires with a diameter greater than 2.4 mm, the range of the simulated collision angles (°) was evaluated in the simulation of 6.0-mm diameter ACL overdrilling and 5.0-mm diameter ALL drilling, using the measured axial angles and D during collisions in this study. The range of the simulated collision angles was obtained using the following formula ([Fig. 3C ]):
(A
xial angle – θ) < S
imulated collision angle < (A
xial angle + θ), sin θ = (3.0 + 2.5) / (D + 1.2).
The range outside the simulated collision angles was defined as the range of simulated no-collision angles. The common range of simulated no-collision angles in all nine knees was identified for each drilling condition: AM120 or 135, PL120 or 135, and Cor0-ALL or Cor30-ALL. Additionally, the ranges of axial angles of ALL K-wires penetrating the trochlea, intercondylar, or popliteal areas were measured, and we evaluated a safe zone, defined as the simulated no-collision angles in which the K-wires did not penetrate the trochlea, intercondylar, or popliteal areas in any of the nine knees under each drilling condition.
Statistical Analysis
Paired t -tests were performed to compare the distance from the ALL footprint to the K-wire outlets between AM120 and AM135 and between PL120 and PL135. In Cor0-ALL and Cor30-ALL, paired t -tests were performed to compare the distance from the ALL footprint to the collision point between AM120 and AM135 as well as between PL120 and PL135. A p -value of < 0.05 was considered statistically significant. All statistical analyses were performed using EZR (Saitama Medical Center, Jichi Medical University, Saitama, Japan),[29 ] which is a graphical user interface for R (version 2.13.0; The R Foundation for Statistical Computing, Vienna, Austria). More precisely, it is a modified version of R commander (version 1.6–3) designed to add statistical functions frequently used in biostatistics.
Results
Safe Zone
The axial angles of ALL K-wires during collisions and the distances from the ALL footprints to collision points are shown in [Tables 1 ] and [2 ], respectively. Based on these data, the common range of simulated no-collision angles was identified for the following combinations of drilling conditions in both Cor0-ALL and Cor30-ALL: PL120/AM120, PL120/AM135, PL135/AM120, and PL135/AM135 ([Table 3 ]). In Cor0-ALL, axial angles greater than 48.7° ± 5.8° (min/max: 39°/54°) penetrated the trochlea, whereas in Cor30-ALL, no axial angles penetrated the trochlea. In Cor0-ALL, axial angles smaller than 1.4° ± 4.8° (min/max: – 5°/8°) penetrated the intercondylar or popliteal areas, whereas in Cor30-ALL, axial angles smaller than 12.2° ± 4.6° (min/max: 3°/18°) penetrated the intercondylar or popliteal areas. According to these findings, the axial angle ranges over which the K-wires did not penetrate the trochlea and intercondylar or popliteal area were 8°–39° in Cor0-ALL and > 18° in Cor30-ALL. By applying these axial angle ranges to each simulated no-collision angle, we identified a safe zone of > 45° in only Cor30-ALL during an ACL drilling combination of PL135/AM120 ([Table 3 ]). No safe zone was identified with the other drilling combinations.
Table 1
Axial angles (°) of ALL drilling during collisions between the ALL and ACL K-wires
Subjects
Cor0-ALL
Cor30-ALL
PL120
PL135
AM120
AM135
PL120
PL135
AM120
AM135
a
32
–
3
8
55
–
15
42
b
2
42
5
16
27
–
30
52
c
– 8
37
–5
5
16
–
8
18
d
10
–
– 1
-2
46
–
17
32
e
25
–
13
37
64
–
23
65
f
–
–
6
10
–
–
32
60
g
47
–
– 1
3
69
–
8
40
h
–
–
– 7
2
–
–
6
35
i
–
–
– 6
5
–
–
6
56
Abbreviations: ACL, anterior cruciate ligament; ALL, anterolateral ligament; K-wire, Kirschner wire; PL120, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 120°; PL135, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 135°; AM120, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 120°; AM135, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 135°; Cor0-ALL, ALL drilling at 0° coronal angle; Cor30-ALL, ALL drilling at 30° coronal angle.
Note: Raw data are presented, and all data are expressed in degrees. The symbol “–” indicates no observed collisions.
Table 2
Distances from the ALL footprint to the collision point
Subjects
Cor0-ALL
Cor30-ALL
PL120
PL135
AM120
AM135
PL120
PL135
AM120
AM135
a
7
–
28
25
5
–
16
15
b
17
17
27
23
20
–
23
19
c
20
13
32
26
10
–
23
20
d
15
–
34
37
11
–
25
22
e
11
–
17
12
9
–
15
10
f
–
–
24
22
–
–
24
15
g
10
–
23
18
10
–
10
7
h
–
–
22
15
–
–
14
10
i
–
–
20
12
–
–
11
11
Abbreviations: ACL, anterior cruciate ligament; ALL, anterolateral ligament; K-wire, Kirschner wire; AM120, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 120°; AM135, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 135°; Cor0-ALL, ALL drilling at 0° coronal angle; Cor30-ALL, ALL drilling at 30° coronal angle; PL120, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 120°; PL135, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 135°.
Note: Raw data are presented, and all data are expressed in mm. The symbol “–” indicates no observed collisions.
Table 3
The common range of simulated no-collision angles and safe zones for different combinations of the ACL and ALL drilling angles
Simulated no-collision angle (°)
Safe zone (°)
Cor0-ALL
Cor30-ALL
Cor0-ALL
Cor30-ALL
PL120/AM120
> 76
–
–
–
PL120/AM135
> 76
–
–
–
PL135/AM120
> 76
> 45
–
> 45
PL135/AM135
> 62
–
–
–
Abbreviations: ACL, anterior cruciate ligament; ALL, anterolateral ligament; AM120, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 120°; AM135, ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 135°; Cor0-ALL, ALL drilling at 0° coronal angle; Cor30-ALL, ALL drilling at 30° coronal angle; PL120, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 120°; PL135, ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 135°.
Note: All data are expressed in degrees. The symbol “–” indicates drilling combinations in which simulated no-collision angles or safe zones were not identified.
Distance from the ALL Footprint to the K-wire Outlet
The point-to-point distances from the ALL footprints to the K-wire outlets were 10.8 ± 3.2, 13.5 ± 3.1, 18.3 ± 5.5, and 16.1 ± 6.5 mm in the PL120, PL135, AM120, and AM135 conditions, respectively. The distances between the ALL footprints and the K-wire outlets in the anterior direction were 9.2 ± 3.1, 11.4 ± 4.2, 9.9 ± 7.0, and 13.7 ± 6.0 mm in the PL120, PL135, AM120, and AM135 conditions, respectively. Finally, the distances between the ALL footprints and the K-wire outlets in the proximal direction were 3.2 ± 5.0, −4.8 ± 4.9, 14.6 ± 3.5, and 7.7 ± 4.7 mm in the PL120, PL135, AM120, and AM135 conditions, respectively (a negative distance indicated the distal direction). The point-to-point distances were significantly longer in the PL135 condition than in the PL120 condition (p = 0.048). Furthermore, the point-to-point distances were significantly longer in the AM120 condition than in the AM135 condition (p = 0.005). In all ACL drilling conditions, the simulated distances were > 0 mm in all knees. The PL135 outlet was situated in a more anterior (p < 0.001) and distal (p = 0.017) location than the PL120 outlet. The AM120 outlet was situated in a more posterior (p < 0.001) and proximal (p < 0.001) location than the AM135 outlet ([Fig. 5A-D ]).
Fig. 5 Locations of Kirschner wire (K-wire) outlet points. Locations of K-wire outlet points during (A ) anterior cruciate ligament (ACL) drilling through the footprint of the anteromedial bundle in the knee flexed at 120° (AM120), (B ) ACL drilling through the footprint of the anteromedial bundle in the knee flexed at 135° (AM135), (C ) ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 120° (PL120), and (D ) ACL drilling through the footprint of the posterolateral bundle in the knee flexed at 135° (PL135). The letters a-i represent outlet points for each knee. The yellow triangle indicates the average location of the nine knees; the red circle indicates the lateral epicondyle; and the blue square indicates the ALL footprint.
Distance from the ALL Footprint to the Collision Point
The distance from the ALL footprint to the collision point was significantly longer in the AM120 condition than in the AM135 condition during Cor0-ALL (25.2 ± 5.5, 21.1 ± 8.0 mm; p = 0.005) and Cor30-ALL (17.8 ± 5.7, 14.3 ± 5.2 mm; p < 0.001). Statistical analysis could not be performed in the PL120 and PL135 conditions, as no collision was observed in several knees. No collisions were observed when the PL drilling outlets were distal to the ALL footprint ([Fig. 5A-D ]), and in the PL135 at any axial angles, during Cor30-ALL.
Discussion
The most important finding of the present study was that the drilling procedure that reduces the risk of femoral tunnel collisions between ACL and ALL tunnels in combined double-bundle ACL and ALL reconstruction is AM drilling at 120° knee flexion and PL drilling at 135° knee flexion in combination with ALL drilling at 30° coronal angle and > 45° axial angle. This recommendation is supported by the following results: (1) the point-to-point distance between the ALL footprint and the K-wire outlet was greater in the AM120 and PL135 conditions than in the AM135 and PL120 conditions; (2) no collision was observed in the PL135 condition in the Cor30-ALL orientation; and (3) with the PL135/AM120 combination, the safe zone was > 45° in Cor30-ALL. The present study and another report[13 ] have shown that the greater the angle of knee flexion, the more distal the location of the K-wire outlet. Furthermore, in the present study, there were no collisions when the PL drilling outlets were distal to the ALL footprint. Therefore, to place the outlets more distally from the ALL footprint, PL drilling with the knee flexed at a minimum of 135° (or greater, if possible) may be better. The optimization of this procedure is clinically relevant, as it may aid surgeons by reducing concerns about tunnel collision during femoral tunnel drilling; consequently, the operation of combined double-bundle ACL and ALL reconstruction can be safely and rapidly performed. However, with the narrow safe zone (> 45°) during the limited ACL drilling procedures (only PL135/AM120 combination), the results of the present study also indicate a high risk of femoral tunnel collisions in combined double-bundle ACL and ALL reconstruction, which is in support of our initial hypothesis.
There are few reports on femoral tunnel collision during combined single-bundle ACL and ALL reconstruction using computed tomography (CT).[14 ]
[18 ]
[30 ] Jette et al[18 ] determined that the ALL femoral tunnel should be drilled at an angle of 30° anterior in the axial plane and 30° proximal in the coronal plane during single-bundle ACL drilling with the knee flexed at 120°. Smeets et al[14 ] observed a high risk of tunnel convergence when performing combined single-bundle ACL and ALL reconstructions, and they reported that the occurrence of tunnel conflicts can be reduced by aiming the ALL tunnel in a more proximal and anterior direction, which supports the results of the present study. The previous computed tomography studies were performed using only two types of axial angles during ALL drillings; as a result, the actual axial angles that caused collisions in each knee were not evaluated. In this study, the axial angles of ALL K-wires during actual collisions were measured, and a safe zone of ALL drilling was evaluated based on these angles.
One option to avoid collisions is to use the same combined femoral tunnel, as described in combined reconstructions of ACL and posterolateral corner,[31 ] and posterior cruciate ligament and medial collateral ligament.[32 ] Sonnery-Cottet et al[33 ] described a technique of combined single-bundle ACL and ALL reconstruction using the same femoral tunnel for the ACL and the ALL. A disadvantage of this technique is that it is not possible to perform double-bundle ACL reconstructions. Moreover, Mediavilla et al[34 ] described a technique of combined double-bundle ACL and ALL reconstruction, using the same femoral tunnel for the PL bundle of the ACL and the ALL. As a disadvantage, the shared graft with one of the ACL bundles and ALL is a one-strand tendon graft because the graft needs to be long; thus, the diameter of the one of the ACL graft is small unless additional grafts are used. Furthermore, these techniques need to be used in an outside-in manner during femoral drilling while placing the guide to an exact position of the femoral ALL and ACL footprint, which is complicated and technical.
Some studies have investigated the relationships between the location of femoral tunnel outlets and the lateral anatomic structures (e.g., the posterior femoral cortex, attachment of the gastrocnemius, FCL, popliteus tendon, and capsule) during ACL femoral drilling through the anteromedial portal.[17 ]
[26 ] These studies concluded that it was more desirable to drill with the knee flexed to 135° rather than to 120° to avoid a posterior blowout and to create the tunnel outlet under the soft tissues. In contrast to these reports, the present study showed that AM femoral drilling was safer at 120° flexion than at 135° flexion when avoiding femoral tunnel collision between ACL and ALL tunnels. Therefore, further studies are needed to investigate the safest femoral drilling procedure during combined double-bundle ACL and ALL reconstruction to prevent femoral tunnel collisions, including all of the lateral anatomic structure injuries.
Moreover, when it is difficult to achieve 135° flexion (for instance owing to joint contracture, thick legs, or a hanging leg position with leg holder), the outlet points of PL drilling should be oriented more proximally to the ALL footprint, resulting in a higher risk of femoral tunnel collision between ACL and ALL tunnels. Although the outside-in technique, which allows the point of the outlets to be controlled on the femoral lateral surface, may be considered, this technique leads to acute graft bending, which is associated with poor graft maturation.[35 ] Therefore, for such knees, femoral drilling using the flexible reamer and curved guide system, which allows a certain degree of control over intra-articular tunnel orientation[36 ] and can produce significantly more anteverted femoral tunnels than those obtained with a rigid drill[37 ] or other fixation methods such as anchors or staples, may be better.
This study had some limitations. First, we had a small sample size. Second, we excised structures surrounding the knee (e.g., the skin, patella, and quadriceps tendon) that may have had an influence on the knee joint alignment during femoral drilling. Third, although simulations for the tunnels utilized for reconstruction grafts were performed by drawing the diameters of tunnels and outlets as circles, these might actually be ellipses (i.e., imperfect circles), because most ACL and ALL drilling is not perpendicular to the lateral surface of the femur or each other. Therefore, the values in this study might have been influenced by these slight differences from clinical operations. Fourth, the cadaver height and the size of the femoral condyle were not evaluated. These characteristics might have been associated with the chance of presenting collisions; thus, they may have affected our results. Finally, the original ALL in each knee was not identified because cadaveric knees embalmed with formaldehyde were used in this study; hence, the ALL footprint was determined as the position of the lateral epicondyle. Future studies using fresh frozen cadaveric knees are required to identify the original ALL.[27 ]
[28 ]
In conclusion, with a narrow safe zone during only PL135/AM120 combination, the risk of femoral tunnel collisions in combined double-bundle ACL and ALL reconstruction is high. AM drilling at 120° and PL drilling at > 135° knee flexion, combined with ALL drilling at 30° coronal angle and > 45° axial angle, may reduce this risk. These findings may enable the combined double-bundle ACL and ALL reconstruction to be safely and rapidly performed by reducing surgeons' concerns regarding femoral tunnel collision.