CC BY 4.0 · Eur J Dent 2023; 17(04): 1316-1324
DOI: 10.1055/s-0042-1758797
Original Article

Effect of Resin Cement at Different Thicknesses on the Fatigue Shear Bond Strength to Leucite Ceramic

Laura Viviana Calvache Arcila
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
,
Laís Carolina Landim Gomes
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
,
Laura Patricia Nadal Ortiz
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
,
Mardoqueu M. da Costa
2   Department of Dentistry, Brasil University, São Paulo, Brazil
,
3   Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
,
Marco Antonio Bottino
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
,
Guilherme de Siqueira Ferreira Anzaloni Saavedra
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
,
Renata Marques de Melo
1   Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, Brazil
› Author Affiliations
Funding This work was supported by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior- CAPES [#88887.475323/2020–00], São Paulo State Research Support Foundation.
 

Abstract

Objectives This in vitro study was performed to evaluate fatigue survival by shear test in the union of leucite-reinforced feldspathic ceramic using different cement thicknesses.

Materials and Methods Leucite-reinforced glass ceramics blocks were sectioned in 2-mm thick slices where resin cylinders were cemented. The samples were distributed in two experimental groups (n = 20) according to the cement thickness (60 and 300 μm). The specimens of each group were submitted to the stepwise fatigue test in the mechanical cycling machine under shear stress state, with a frequency of 2 Hz, a step-size of 0.16 bar, starting with a load of 31 N (1.0 bar) and a lifetime of 20,000 cycles at each load step.

Results The samples were analyzed in a stereomicroscope and scanning electron microscopy to determine the failure type. There is no significant difference between the mean values of shear bond strength according to both groups. Log-rank (p = 0.925) and Wilcoxon (p = 0.520) tests revealed a similar survival probability in both cement layer thicknesses according to the confidence interval (95%). The fracture analysis showed that the mixed failure was the most common failure type in the 300-μm thickness group (80%), while adhesive failure was predominant in the 60-μm thickness group (67%). The different cement thicknesses did not influence the leucite ceramic bonding in fatigue shear testing; however, the thicker cement layer increased the predominance of the ceramic material failure.

Conclusion The resin cement thicknesses bonded to leucite ceramic did not influence the long-term interfacial shear bond strength, although thicker cement layer increased the ceramic material cohesive failure. Regardless the cement layer thickness, the shear bond strength lifetime decreases under fatigue.


#

Introduction

Dental ceramics are materials routinely used in aesthetic restorative procedures due to their excellent properties, such as high compressive strength, high translucency and fluorescence, chemical stability, low electrical conductivity, and the similar thermal expansion coefficient to the dental substrate.[1]

The cementation of dental ceramics is a widely studied clinical step, which should be done meticulously to achieve a durable bond strength to the dental substrate.[2] [3] Thus, resin cements are the first choice materials during the cementation of glass-ceramics restorations, as they provide the advantage of mechanical bonding in addition to the chemical adhesion provided by silanes coupling agent.[4] [5]

Several factors affect the bond strength of the resin cement with the restoration, such as the restoration material, the adhesive system, the cement polymerization mode, the different surface treatments, the proper application of silane coupling agent, and the presence of surface contaminants.[3] [4] [5] [6]

In addition to the reported parameters, literature shows the influence of resin cement thickness on the fracture resistance of ceramic restorations.[7] The authors analyzed the influence of cement thickness and ceramic/cement bonding on the stresses and failures of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns using finite element analysis and monotonic tests. The major findings were that the occlusal “fitting” may promote structural implications in the CAD/CAM crowns; and precementation spaces around 50 to 100μm are recommended.[7]

According to the literature, the benefits of adhesive dentistry are dampened with a cement thickness close to 450 to 500μm due to polymerization shrinkage stresses.[6] [7] However, a previous report concluded that the cement layer thickness did not interfere in the mechanical performance of ceramic restorations.[8] [9] However, there is a lack of information in literature regarding the influence of cement thickness on the bond strength durability.

Besides to the previously described, the presence of moisture and chewing loads in the oral cavity are factors capable of impairing the restoration longevity with the degradation of cement layer, slow crack growth, and fatigue.[10] The masticatory loads promote mechanical degradation, whereas moisture corrodes the chemical bonds at the ceramic crack tip. In the same manner, moisture from saliva and dentinal tubule can also greatly influence the degradation of resin cements, and finally leads to failure at the adhesive interface.[10] However, the survival probabilities regarding the fatigue of ceramic bonded to cements have not been assessed so far.

Therefore, there is lack of scientific evidence in literature showing the influence of mechanical fatigue on the resin cement and glass ceramic bond strength survival. The objective of this study was to assess the bond strength survival of leucite-reinforced feldspathic ceramic (IPS Empress CAD Multi, Ivoclar Vivadent, Schaan, Liechtenstein) during shear stress using different cement thicknesses. The null hypothesis was that the different cement thicknesses will not influence the fatigue shear bond strength of leucite-reinforced feldspathic ceramic.


#

Materials and Methods

First, specimens were made using leucite-reinforced glass ceramics to evaluate the influence of cement thickness on the shear bond to leucite-reinforced feldspathic ceramics, where a resin cylinder was cemented on one of the sides for it to be subjected to the mechanical shear test. The materials used in this study are shown in [Table 1].

Table 1

Trade market, batch number, manufacturer, and chemical composition of the materials used in this in vitro study

Product

Material type

Chemical composition

Batch number

Manufacturer

Empress CAD

Leucite-reinforced glass ceramic

SiO2: 60.0–65.0

Al2O3: 16.0–20.0

K2O: 10.0–14.0

Na2O: 3.5–6.5

Other oxides: 0.5–7.0

Pigments: 0.2–1.0

X49765

Ivoclar Vivadent AG, Liechtenstein

Multilink N

Resin cement

Alcohol solution of silane methacrylate, phosphoric acid methacrylate, and sulfide methacrylate

W44613

Ivoclar Vivadent AG, Liechtenstein

Condac Porcelana (5%)

Hydrofluoric acid

10% hydrofluoric acid, water, thickener, surfactant, and pigment

030518

FGM; Joinville, SC, Brazil

Opallis

Microhybrid composite resin

Bis-GMA monomers, Bis-EMA, TEGDMA, UDMA, camphorquinone, co-initiator, silane, silanized barium-aluminum silicate glass, pigments

240516

FGM; Joinville, SC, Brazil

Monobond N

Silane

3-Methacryloxypropyltrimethoxysilane, ethanol, water

W90329

Ivoclar Vivadent AG, Liechtenstein

Abbreviations: Bis-EMA, bisphenol A ethoxylated dimethacrylate; Bis-GMA, bisphenol A-glycidyl methacrylate; TEGDMA, triethylene glycol dimethacrylate; UDMA, urethane dimethacrylate.


Ceramic Processing

Ceramic blocks (IPS Empress CAD Multi) were obtained and then sectioned in a standardized manner using a precision cutter (Isomet 1000; Buehler, Lake Bluff, Illinois, United States) under constant water cooling to obtain 2-mm thick slices (5 × 5 mm). A total of 40 slices were obtained, which were polished in a polishing machine with 600 grit sandpaper under constant water cooling. Then, they were randomly distributed into two experimental groups according to the cement thickness used in the cementation of the ceramic (n = 20).


#

Resin Cylinders Manufacturing

Composite resin cylinders (Opallis, FGM, Joinville, Brazil) (3.2 mm × 4 mm) were made using a standardized silicone matrix and the incremental technique under a glass slide to obtain a completely smooth surface, and light curing was performed for 30 seconds on each layer with light source unity (Blue Phase, Ivoclar Vivadent) at a light intensity of 1,200 mW/cm2.


#

Standardization of Cement Thickness

To standardize the cement thickness, a pilot study was performed in which the specimens were cemented witch different weights at static load. After the cementation, the specimens were embedded in acrylic resin cylinders (2.5 cm × 2.5 cm) and cut into halves using a precision cutter (Isomet 1000; Buehler). Then, each sectioned sample was submitted to the microscopy analysis (Discovery V20, Carl Zeiss, Jena, Germany) aiming to define the average thickness generated by each load. In the end, the control group (60 μm thickness) was achieved with a load of 51.2 g and the second group (300 μm thickness) received a higher weight of 811 g ([Fig. 1]). Therefore, in the present study one group presented a thin cement layer (60 μm) and the other group presented 5× this cement layer thickness (300 μm).

Zoom Image
Fig. 1 Stereomicroscope analyses to standardize the thickness cement of the groups under magnification of 24.5 × . (A) 300 μm group, (B) 60 μm group.

#

Cementation of Specimen

Next, the ceramic surface was isolated with a perforated matrix correspondent to the adhesive area of the cylinders samples to avoid excess of cement ([Fig. 2]). The isolated surface was etched with hydrofluoric acid 5% ([Fig. 2A]) (Condac Porcelain, FGM) for 60 seconds, washed with water for 60 seconds, and then a jet of air was used for 15 seconds to dry the surface. The silane (Monobond N, Ivoclar Vivadent) was applied with the aid of a microbrush for 60 seconds ([Fig. 2B]). After surface treatments, the resin cement (Multilink N, Ivoclar Vivadent) pastes were mixed as recommended by the manufacturer and applied on the center of the treated ceramic surface and on its counterpart on the resin cylinders. The ceramic and the cylinders were bonded together and a static load of 51.2 g weight was applied to the top surface of the cylinder to the 300-μm group; and a load of 810 g was used to the 60-μm group ([Fig. 2C]). Then, the cement excesses were removed, and light activation (1200 mW/cm2, Bluephase N, Ivoclar Vivadent) was performed in five exposures of 20 seconds on each side of the sample. The etched ceramic surface and the polished ceramic can be observed with scanning electron microscope (SEM) in [Fig. 3].

Zoom Image
Fig. 2 Cementation process with a perforated matrix. (A) Isolated surface etching with hydrofluoric acid 5%. (B) Silane applying with the aid of a microbrush. (C) Cementation of the resin cylinders using static loading.
Zoom Image
Fig. 3 Topography micrographs of ceramic under 2000× magnification. (A) Polished ceramic. (B) Acid etched ceramic.

#

Monotonic Test

The immediate bond strength test was performed to determine the fatigue survival test profiles. To do so, a microshear assay (DL-1000, EMIC, Instron, São Jose dos Campos, Brazil) was performed with a load cell of 20 kgf (0.5 mm/min) in the samples (n = 6) of both groups ([Fig. 4A]).

Zoom Image
Fig. 4 (A) Monotonic test and (B) fatigue test device.

#

Stepwise Fatigue Test

The stepwise test corresponds to a simulation of a clinical situation through the cycling of the samples with increasing load until material failure or up to a predetermined number of cycles.[11] [12] [13] [14] The fatigue test parameters were defined according to the monotonic test results: the frequency was 2 Hz, with step size of 0.16 bar, starting with a load of 31 N (1.0 bar) during 20,000 cycles at each load step until the survival or failure of the sample (suspension). The specimens of each group (n = 20) were submitted to a fatigue test in a mechanical cycler (Biocycle, BIOPDI, São Carlos, São Paulo, Brazil). The uniaxial load was applied with a 12-mm diameter stainless steel piston in the lateral surface of the ceramic, which was supported and arrested between two flat steel bases perpendicular to the load incidence. The test was performed with the samples submerged in water ([Fig. 4B]).


#

Failure Analysis

After the fracture, the samples were analyzed in a stereomicroscope (Discovery V20, Carl Zeiss) under magnification of 7.5× to determine the failure type, and representative specimens (n = 3) from each group have been analyzed with SEM (FEG-SEM, Inspect S50; FEI Company, Brno, Czech Republic) in high vacuum, using a voltage of 25 Kv. Previously, the samples were metallized using the EMITECH SC7620 Sputter Coater metallizer, resulting in a 12-nm gold alloy layer over each sample. Two distinct types of failure were recorded: (1) adhesive failure was recorded when the bond failure was observed in the ceramic and (2) mixed failure was recorded when involving the cement and ceramic surface. The images were observed in secondary electrons and backscattered electrons at low and high magnification ([Fig. 5]).

Zoom Image
Fig. 5 Failure type under 50 X magnification. (A) Adhesive failure in the 300-μm group. (B) Mixed ceramic failure in the 300-μm group. (C) Adhesive failure in the 60-μm group. (D) Mixed ceramic failure in the 60-μm group. C, ceramic; CE, cement; AS, adhesive surface.

#

Data Analysis

The fatigue data were subjected to a Kaplan–Meier analysis with post hoc Mantel–Cox (log-rank) and Wilcoxon test (α = 0.05) (IBM SPSS Software; IBM, Armonk, New York, United States), as well as a reliability analysis by the Weibull test (Weibull ++, Reliasoft, Tucson, Arizona, United States). The mean between monotonic and fatigue test was calculated. The failures were classified and the percentages of each type of failure computed.


#
#

Results

The Kaplan–Meier fatigue survival chart and the Weibull probability plots versus number of cycles during the fatigue test are presented in [Figs. 6] and [7], respectively. There is no significant difference between the mean values of shear bond strength according to both groups comparison. Log-rank (p = 0.925) and Wilcoxon (p = 0.520) tests revealed a similar survival probability in both cement thickness groups (300 and 60 μm) according to the confidence interval ([Table 2]). In addition, the sample failure during the fatigue test increased progressively with the increase in the number of cycles and load (N). The Kaplan–Meier estimates are presented in [Table 3]. No differences in mean values of bond strength (MPa) were observed between the two thicknesses for monotonic and fatigue tested interfaces ([Table 4]).

Zoom Image
Fig. 6 Survival plot using the Kaplan–Meier method, average and median strength of samples during the fatigue test.
Zoom Image
Fig. 7 Reliability plot showing that samples will fail as the time under fatigue increases in both groups. The Weibull modulus (β) and characteristic life (η) for 300 and 60 µm groups were respectively: β = 3.2 and 3.3 and η = 94,000 and 90,000 cycles.
Table 2

Survival probability in both cementation thickness groups (300 and 60 μm) according to the confidence interval of log-rank (p 0.925) and Wilcoxon (p 0.520) method

Method

Chi-squared

DF

p-Value

Log-rank

0.008764

1

0.925

Wilcoxon

0.413978

1

0.520

Note: Kaplan–Meier analysis with post hoc Mantel–Cox (log-rank) and Wilcoxon test (α = 0.05). Abbreviation: DF, Degree of freedom.


Table 3

Results of shear bond fatigue test in MPa, number under risk, surviving specimens, survival probability, standard error, and confidence intervals (CIs)

Cement thickness

MPa

Number under

risk

Surviving

specimens

Survival probability

Standard error

CI of 95.0%

Lower

Upper

300 μm

5.28

236

20

0.915254

0.0181290

0.879722

0.950786

10.32

159

16

0.605932

0.0318084

0.543589

0.668275

15.36

100

13

0.368644

0.0314040

0.307093

0.430195

20.40

49

9

0.169492

0.0244225

0.121624

0.217359

25.44

18

6

0.050847

0.0143003

0.022819

0.078876

30.47

1

1

0.000000

0.000000

0.000000

0.000000

60 μm

5.28

225

20

0.911111

0.0189722

0.873926

0.948296

10.32

147

17

0.577778

0.0329276

0.513241

0.642315

15.36

84

12

0.320000

0.0310984

0.259048

0.380952

20.40

45

8

0.164444

0.0247119

0.116010

0.212879

25.44

20

4

0.071111

0.0171340

0.037529

0.104693

30.47

5

3

0.008889

0.0062574

0.000000

0.021153

Note: Kaplan–Meier analysis with post hoc Mantel–Cox (log-rank) and Wilcoxon test (α = 0.05).


Table 4

Mean values of bond strength (MPa) obtained in monotonic and fatigue tests

Groups

Mean bond strength (MPa)

Cement thickness

Monotonic test

Fatigue test

300 μm

23.32

20.52

60 μm

26.86

19.96

The fracture analysis showed that predominantly ceramic mixed failure was the most common failure type in the 300-μm thickness group (80%), followed by adhesive failure (20%). Moreover, the adhesive failure was predominant in the 60-μm thickness group (67%), followed by mixed failure (33%). The results (%) are shown in [Fig. 8]. The images of failed specimens of each group and the topography micrographs polished and etched of ceramic obtained with the SEM are shown in [Figs. 4] and [5], respectively.

Zoom Image
Fig. 8 Type of failure data of each group (%) regarding the scanning electron microscope (SEM) analysis.

#

Discussion

The goal was to assess the bond strength survival of leucite-reinforced feldspathic ceramic during shear stress using different cement thicknesses. The results showed that the cement thickness did not influence the bond strength survival, thus confirming the null hypothesis.

The leucite-based ceramic (SiO2, Al2O3, K2O, Na2O, other oxides, and pigments) are rich in silica, being considered an acid-sensitive ceramic.[4] It is in the glass-matrix structure that the hydrofluoric acid will modify the surface topography and form micro-retentions which improve the bond strength with cement material. Thus, this type of dental ceramic presents a strong bond strength with resinous cements, which endorses our findings. However, the literature reports that the polymerization shrinkage during light curing generates residual stress at the adhesive interface and reduces the adhesion durability of bonded ceramics with a thick cement layers.[15] [16] Overall, the matter regarding cement thickness has been much explored in fiber post-studies; and a consensus about the association of thinner cement layer and higher bond strengths already exists.[17] [18] Thus, according to the previous studies, the presence of voids and bubbles are responsible for the decrease of bond strength in thicker cement layers.

However, the well-controlled scenario during cementation and the flat surfaces in the present study probably impaired the inclusion of such defects and no differences were found between 300 and 60 μm cementation layers.

In addition to the defects population on the cement, Fleming et al[19] found that the volumetric shrinkage of the resin cement generates compressive stress at the interface, producing residual stress that allow the crack growth phenomena.[19] On the other hand, marginal discrepancy and lower bond strength caused by thicker resinous materials could be more evident in complex geometry, such as crowns, due to high polymerization shrinkage of the cement.[20] [21] In addition, a thicker cement film exposes more polymeric material to the oral environment, increasing its susceptibility to the degradation.[22] [23] [24] It was reported that the acceptable cement thickness for dental restorations should be up to 120 μm.[25] Therefore, in the present study one group presented a clinically acceptable thickness (60 μm) and the other present 5× the cement layer height (300 μm). Despite this difference, the bond strength was similar between both.

One important aspect in bond strength studies is the failure mode evaluation. Adhesive failures occurs when there is no critical damage caused in the ceramic surface, and this factor is particularly important because these results are closer to the real bond strength between ceramic and cement. On the other hand, the thicker cement layer (300 μm) presented predominantly failures involving the ceramic substrate, with chipping of the ceramic surface. This result was caused probably due to the increase in the momentum during the test and the residual stress by the bigger cement volume. This may clinically signify that a cushioning effect between the crown and dentine due to the presence of a low elastic modulus layer (cement) under a much stiffer material (ceramic crown) is potentially lost in the 300-μm cement layer, thus leading to tensile fracture of the ceramic at the surface.[24] [25]

The reliability of both groups was the same and express that the bond strength will diminish over time due to fatigue, and 63.2% of the specimens will fail by around 90,000 cycles. In this study, a mechanical fatigue machine was applied for the aging process, but the specimens were immerged in water which can also contribute to cement plasticization and interfacial degradation.

For the lifetime prediction of a fatigue test to be considered clinically relevant, the evaluated restorations should be evaluated for at least 106 cycles. This period of aging would correspond to approximately 1 year of clinical use. Considering three periods of 15 minutes of chewing per day, the individual average of chewing is 2,700 times a day with a frequency of 1 Hz.[26] These parameters may vary depending on the applied load and frequency.

The results obtained in our study regarding the survival analyses (Kaplan–Meier) show that more than half of the samples in both groups (300 and 60 μm) failed with approximately 20.40 MPa, and consequently the survival probability drops by a half with every cycle. The reliability plot also showed the same trend, as reliability decreased over time under fatigue. This shows the necessity of further analysis using fatigue tests to predict the long-term behavior of bonded restorations.

Dal Piva et al[27] observed shear stress and tensile stress simultaneously; however, they found high shear stress at the interface of the tested materials than tensile stress. In this study, the shear bond test was performed for monotonic and fatigue tests, in which the monotonic values were used to obtain the fatigue profile and load steps for the survival curve of each thickness group. This methodology was widely applied in studies that evaluated failures in restorative materials,[12] [14] [28] [29] however, never with the present setup to test shear bond durability.

In this study, the cement thickness was standardized by applying a specific amount of weight using an adapted apparatus device for each specimen ([Fig. 2A]). The study of Ustun and Ayaz[30] used digital pressure when the resin cement was applied to the ceramic surfaces and seated to the dentin, which technically is not a standardizable procedure since there is no measured and control, and different pressures could be applied depending of the operator. A previous study applied different weights using a standardized pressure device,[31] and similar to the present study the authors were able to control the cement layer thickness; however, they also reported the need to check each sample under microscopy prior to the bond strength test due to the technique sensitivity.[31]

According to the results of this study, the different cement thicknesses in the adhesive interface with leucite-reinforced feldspathic did not influence the fatigue behavior during cyclic shear stress state. However, we still advocate the control of cement thickness for better results in ceramic crowns restorations.[32]

An important limitation inherent from the present study was the load application method. When testing adhesion using shear bond test, a combination of shear and tensile forces occur at the interface, resulting in complex stresses. In addition, the jig design applied in the in vitro setup show variations complicating direct comparison between studies.[33] Therefore, the comparisons between different shear bond strength methods should be carefully performed since the stress distributions have nonuniform tensile or shear stress states at the interface due to different specimens' geometries and loading configuration (i.e., wire loop, knife edge, blade, hook, point of loading, alignment, stressing rate) and modulus of elasticity of the evaluated materials.[34] Since the present study applied the fatigue loading using a different testing device, the results presented here could have been affected by it, in a similar way for both evaluated groups.

Comparing the loading method for shear bond strength test, the wire-loop, notched-rod, and knife-edge chisel are usually reported as the most preferred blade designs.[35] Since the knife-edge chisel transmits the force to the tested sample from a single point, a heterogeneous force transmission is observed. Despite that, the failure mode between the different application methods seems to be similar.[35] According to the literature, problems related to the validity of shear bond strength values started to arise as cohesive failures in the substrate were frequently observed with adhesives that yield improved bond strengths.[36]

Therefore, as expected, not only the loading setup should affect the failure mode and force distribution, but also the evaluated materials.[33] [34] [35] [36] [37] [38] [39] Therefore, further fatigue bond-strength tests should be developed, assessing not only the reliability of bonded restorations but also the loading method stresses.

Considering the limitations of an in vitro study, such as the use of an accelerated life test and nonanatomic specimens, further investigations could be considered to analyze the influence of the cement thickness in conditions simulating anatomical specimens, as well as the behavior under different surface treatments, different ceramic materials, and varying load profiles in the adhesively cemented restorations.


#

Conclusion

The resin cement thicknesses bonded to leucite ceramic did not influence the long-term interfacial shear bond strength, although thicker cement layer increased the chances of ceramic cohesive failure. Regardless the cement layer thickness, the shear bond strength lifetime decreases under fatigue.


#
#

Conflict of Interest

The author(s) declare(s) that there is no conflict of interest regarding the publication of this paper.

Acknowledgment

The authors thank Ivoclar for the materials donation.

Data Availability

Data available on request of the first or second authors.


  • References

  • 1 Borges GA, Sophr AM, de Goes MF, Sobrinho LC, Chan DC. Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics. J Prosthet Dent 2003; 89 (05) 479-488
  • 2 Cura C, Saraçoglu A, Cötert HS. Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel. J Prosthet Dent 2003; 89 (04) 394-399
  • 3 Graiff L, Piovan C, Vigolo P, Mason PN. Shear bond strength between feldspathic CAD/CAM ceramic and human dentine for two adhesive cements. J Prosthodont 2008; 17 (04) 294-299
  • 4 Tribst J, Anami LC, Özcan M, Bottino MA, Melo RM, Saavedra G. Self-etching primers vs acid conditioning: impact on bond strength between ceramics and resin cement. Oper Dent 2018; 43 (04) 372-379
  • 5 Uwalaka CO, Karpukhina N, Cao X, Bissasu S, Wilson RM, Cattell MJ. Effect of sandblasting, etching and resin bonding on the flexural strength/bonding of novel glass-ceramics. Dent Mater 2018; 34 (10) 1566-1577
  • 6 Moura DMD, Araújo AMM, Souza KB, Veríssimo AH, Tribst JPM, Souza ROAE. Hydrofluoric acid concentration, time and use of phosphoric acid on the bond strength of feldspathic ceramics. Braz Oral Res 2020; 34: e018
  • 7 May LG, Kelly JR, Bottino MA, Hill T. Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing. Dent Mater 2012; 28 (08) e99-e109
  • 8 Tribst JPM, Dal Piva AMO, Penteado MM, Borges ALS, Bottino MA. Influence of ceramic material, thickness of restoration and cement layer on stress distribution of occlusal veneers. Braz Oral Res 2018; 32: e118
  • 9 Venturini AB, Wandscher VF, Marchionatti AME. et al. Effect of resin cement space on the fatigue behavior of bonded CAD/CAM leucite ceramic crowns. J Mech Behav Biomed Mater 2020; 110: 103893
  • 10 Martins LM, Lorenzoni FC, Farias BC, Lopes LD, Bonfante G, Rubo JH. Biomechanical behavior of dental ceramics. Ceramica 2010; 56: 148-155
  • 11 Güth JF, Edelhoff D, Goldberg J, Magne P. CAD/CAM polymer vs direct composite resin core buildups for endodontically treated molars without ferrule. Oper Dent 2016; 41 (01) 53-63
  • 12 Anami LC, Lima JM, Valandro LF, Kleverlaan CJ, Feilzer AJ, Bottino MA. Fatigue resistance of Y-TZP/porcelain crowns is not influenced by the conditioning of the intaglio surface. Oper Dent 2016; 41 (01) E1-E12
  • 13 Carvalho AO, Bruzi G, Giannini M, Magne P. Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process. J Prosthet Dent 2014; 111 (04) 310-317
  • 14 Tribst JPM, Dal Piva AMO, Borges ALS, Anami LC, Kleverlaan CJ, Bottino MA. Survival probability, Weibull characteristics, stress distribution, and fractographic analysis of polymer-infiltrated ceramic network restorations cemented on a chairside titanium base: an in vitro and in silico study. Materials (Basel) 2020; 13 (08) 1879
  • 15 Correia A, Andrade MR, Tribst J, Borges A, Caneppele T. Influence of bulk-fill restoration on polymerization shrinkage stress and marginal gap formation in Class V restorations. Oper Dent 2020; 45 (04) E207-E216
  • 16 Angelo E, Lins RE, Martins LR. The finish line location of the cemented crown is an influencing factor for tensile bond strength, marginal adaption and nanoleakage?. Braz Dent Sci 2020; 23 (02) 10
  • 17 Özcan E, Çetin AR, Tunçdemir AR, Ülker M. The effect of luting cement thicknesses on the push-out bond strength of the fiber posts. Acta Odontol Scand 2013; 71 (3-4): 703-709
  • 18 Gomes GM, Rezende EC, Gomes OM, Gomes JC, Loguercio AD, Reis A. Influence of the resin cement thickness on bond strength and gap formation of fiber posts bonded to root dentin. J Adhes Dent 2014; 16 (01) 71-78
  • 19 Fleming GJP, Cao X, Romanyk DL, Addison O. Favorable residual stress induction by resin-cementation on dental porcelain. Dent Mater 2017; 33 (11) 1258-1265
  • 20 Hsu P, Ramos Jr V, Sadr A. Microcomputed tomography evaluation of cement shrinkage under zirconia versus lithium disilicate veneers. J Prosthet Dent 2021; 125 (02) 307-315
  • 21 Borges AL, Dal Piva AM, Moecke SE, de Morais RC, Tribst JP. Polymerization shrinkage, hygroscopic expansion, elastic modulus and degree of conversion of different composites for dental application. J Composites Sci 2021; 5 (12) 322
  • 22 Sampaio CS, Barbosa JM, Cáceres E. et al. Volumetric shrinkage and film thickness of cementation materials for veneers: an in vitro 3D microcomputed tomography analysis. J Prosthet Dent 2017; 117 (06) 784-791
  • 23 Gressler May L, Kelly JR, Bottino MA, Hill T. Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns. Dent Mater 2015; 31 (08) 895-900
  • 24 Silva EM, Noronha-Filho JD, Amaral CM, Poskus LT, Guimarães JG. Long-term degradation of resin-based cements in substances present in the oral environment: influence of activation mode. J Appl Oral Sci 2013; 21 (03) 271-277
  • 25 Almeida e Silva JS, Erdelt K, Edelhoff D. et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 2014; 18 (02) 515-523
  • 26 Lohbauer U, Krämer N, Petschelt A, Frankenberger R. Correlation of in vitro fatigue data and in vivo clinical performance of a glass ceramic material. Dent Mater 2008; 24 (01) 39-44
  • 27 Dal Piva AM, Tribst JP, Bottino MA. Evaluation of shear bond strength and shear stress on zirconia reinforced lithium silicate and high translucency zirconia. J Oral Res 2018; 7 (01) 30-36
  • 28 Schmitt de Andrade G, Diniz V, Datte CE. et al. Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2019; 95: 172-179
  • 29 Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers. J Prosthet Dent 2010; 104 (03) 149-157
  • 30 Ustun S, Ayaz EA. Effect of different cement systems and aging on the bond strength of chairside CAD-CAM ceramics. J Prosthet Dent 2021; 125 (02) 334-339
  • 31 Tribst JPM, Dos Santos AFC, da Cruz Santos G. et al. Effect of cement layer thickness on the immediate and long-term bond strength and residual stress between lithium disilicate glass-ceramic and human dentin. Materials (Basel) 2021; 14 (18) 5153
  • 32 May LG, Kelly JR. Influence of resin cement polymerization shrinkage on stresses in porcelain crowns. Dent Mater 2013; 29 (10) 1073-1079
  • 33 Scherrer SS, Cesar PF, Swain MV. Direct comparison of the bond strength results of the different test methods: a critical literature review. Dent Mater 2010; 26 (02) e78-e93
  • 34 Özcan M, Kojima AN, Nishioka RS, Mesquita AM, Bottino MA, Filho GD. Effect of jig design and assessment of stress distribution in testing metal-ceramic adhesion. J Prosthodont 2016; 25 (08) 665-669
  • 35 Placido E, Meira JB, Lima RG, Muench A, de Souza RM, Ballester RY. Shear versus micro-shear bond strength test: a finite element stress analysis. Dent Mater 2007; 23 (09) 1086-1092
  • 36 Ergin ES, Soygun K, Aygun EB, Kurtoglu C. The effect of different blade designs on shear bond strength of veneering ceramics fused to zirconia. J Australian Ceramic Soc 2021; 57 (05) 1463-1470
  • 37 Sebben J, Canevese VA, Alessandretti R. et al. Effect of surface coating on bond strength between etched feldspar ceramic and resin-based luting agents. BioMed Res Int 2018; 2018: 3039251
  • 38 Klaisiri A, Krajangta N, Thamrongananskul N. The durability of zirconia/resin composite shear bond strength using different functional monomer of universal adhesives. Eur J Dent 2022; 16 (04) 756-760
  • 39 Al-Ali AMAH, Khalifa N, Hadj-Hamou A, Sheela S, El-Damanhoury HM. Effect of thickness and bonding technique on fatigue and fracture resistance of feldspathic ultra-thin laminate veneers. Eur J Dent 2023; 17 (02) 431-438

Address for correspondence

João Tribst
Gustav Mahlerlaan 3004, 1081 LA Amsterdam
The Netherlands   

Publication History

Article published online:
19 December 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Borges GA, Sophr AM, de Goes MF, Sobrinho LC, Chan DC. Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics. J Prosthet Dent 2003; 89 (05) 479-488
  • 2 Cura C, Saraçoglu A, Cötert HS. Effect of different bonding agents on shear bond strengths of composite-bonded porcelain to enamel. J Prosthet Dent 2003; 89 (04) 394-399
  • 3 Graiff L, Piovan C, Vigolo P, Mason PN. Shear bond strength between feldspathic CAD/CAM ceramic and human dentine for two adhesive cements. J Prosthodont 2008; 17 (04) 294-299
  • 4 Tribst J, Anami LC, Özcan M, Bottino MA, Melo RM, Saavedra G. Self-etching primers vs acid conditioning: impact on bond strength between ceramics and resin cement. Oper Dent 2018; 43 (04) 372-379
  • 5 Uwalaka CO, Karpukhina N, Cao X, Bissasu S, Wilson RM, Cattell MJ. Effect of sandblasting, etching and resin bonding on the flexural strength/bonding of novel glass-ceramics. Dent Mater 2018; 34 (10) 1566-1577
  • 6 Moura DMD, Araújo AMM, Souza KB, Veríssimo AH, Tribst JPM, Souza ROAE. Hydrofluoric acid concentration, time and use of phosphoric acid on the bond strength of feldspathic ceramics. Braz Oral Res 2020; 34: e018
  • 7 May LG, Kelly JR, Bottino MA, Hill T. Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing. Dent Mater 2012; 28 (08) e99-e109
  • 8 Tribst JPM, Dal Piva AMO, Penteado MM, Borges ALS, Bottino MA. Influence of ceramic material, thickness of restoration and cement layer on stress distribution of occlusal veneers. Braz Oral Res 2018; 32: e118
  • 9 Venturini AB, Wandscher VF, Marchionatti AME. et al. Effect of resin cement space on the fatigue behavior of bonded CAD/CAM leucite ceramic crowns. J Mech Behav Biomed Mater 2020; 110: 103893
  • 10 Martins LM, Lorenzoni FC, Farias BC, Lopes LD, Bonfante G, Rubo JH. Biomechanical behavior of dental ceramics. Ceramica 2010; 56: 148-155
  • 11 Güth JF, Edelhoff D, Goldberg J, Magne P. CAD/CAM polymer vs direct composite resin core buildups for endodontically treated molars without ferrule. Oper Dent 2016; 41 (01) 53-63
  • 12 Anami LC, Lima JM, Valandro LF, Kleverlaan CJ, Feilzer AJ, Bottino MA. Fatigue resistance of Y-TZP/porcelain crowns is not influenced by the conditioning of the intaglio surface. Oper Dent 2016; 41 (01) E1-E12
  • 13 Carvalho AO, Bruzi G, Giannini M, Magne P. Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process. J Prosthet Dent 2014; 111 (04) 310-317
  • 14 Tribst JPM, Dal Piva AMO, Borges ALS, Anami LC, Kleverlaan CJ, Bottino MA. Survival probability, Weibull characteristics, stress distribution, and fractographic analysis of polymer-infiltrated ceramic network restorations cemented on a chairside titanium base: an in vitro and in silico study. Materials (Basel) 2020; 13 (08) 1879
  • 15 Correia A, Andrade MR, Tribst J, Borges A, Caneppele T. Influence of bulk-fill restoration on polymerization shrinkage stress and marginal gap formation in Class V restorations. Oper Dent 2020; 45 (04) E207-E216
  • 16 Angelo E, Lins RE, Martins LR. The finish line location of the cemented crown is an influencing factor for tensile bond strength, marginal adaption and nanoleakage?. Braz Dent Sci 2020; 23 (02) 10
  • 17 Özcan E, Çetin AR, Tunçdemir AR, Ülker M. The effect of luting cement thicknesses on the push-out bond strength of the fiber posts. Acta Odontol Scand 2013; 71 (3-4): 703-709
  • 18 Gomes GM, Rezende EC, Gomes OM, Gomes JC, Loguercio AD, Reis A. Influence of the resin cement thickness on bond strength and gap formation of fiber posts bonded to root dentin. J Adhes Dent 2014; 16 (01) 71-78
  • 19 Fleming GJP, Cao X, Romanyk DL, Addison O. Favorable residual stress induction by resin-cementation on dental porcelain. Dent Mater 2017; 33 (11) 1258-1265
  • 20 Hsu P, Ramos Jr V, Sadr A. Microcomputed tomography evaluation of cement shrinkage under zirconia versus lithium disilicate veneers. J Prosthet Dent 2021; 125 (02) 307-315
  • 21 Borges AL, Dal Piva AM, Moecke SE, de Morais RC, Tribst JP. Polymerization shrinkage, hygroscopic expansion, elastic modulus and degree of conversion of different composites for dental application. J Composites Sci 2021; 5 (12) 322
  • 22 Sampaio CS, Barbosa JM, Cáceres E. et al. Volumetric shrinkage and film thickness of cementation materials for veneers: an in vitro 3D microcomputed tomography analysis. J Prosthet Dent 2017; 117 (06) 784-791
  • 23 Gressler May L, Kelly JR, Bottino MA, Hill T. Influence of the resin cement thickness on the fatigue failure loads of CAD/CAM feldspathic crowns. Dent Mater 2015; 31 (08) 895-900
  • 24 Silva EM, Noronha-Filho JD, Amaral CM, Poskus LT, Guimarães JG. Long-term degradation of resin-based cements in substances present in the oral environment: influence of activation mode. J Appl Oral Sci 2013; 21 (03) 271-277
  • 25 Almeida e Silva JS, Erdelt K, Edelhoff D. et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 2014; 18 (02) 515-523
  • 26 Lohbauer U, Krämer N, Petschelt A, Frankenberger R. Correlation of in vitro fatigue data and in vivo clinical performance of a glass ceramic material. Dent Mater 2008; 24 (01) 39-44
  • 27 Dal Piva AM, Tribst JP, Bottino MA. Evaluation of shear bond strength and shear stress on zirconia reinforced lithium silicate and high translucency zirconia. J Oral Res 2018; 7 (01) 30-36
  • 28 Schmitt de Andrade G, Diniz V, Datte CE. et al. Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations. J Mech Behav Biomed Mater 2019; 95: 172-179
  • 29 Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers. J Prosthet Dent 2010; 104 (03) 149-157
  • 30 Ustun S, Ayaz EA. Effect of different cement systems and aging on the bond strength of chairside CAD-CAM ceramics. J Prosthet Dent 2021; 125 (02) 334-339
  • 31 Tribst JPM, Dos Santos AFC, da Cruz Santos G. et al. Effect of cement layer thickness on the immediate and long-term bond strength and residual stress between lithium disilicate glass-ceramic and human dentin. Materials (Basel) 2021; 14 (18) 5153
  • 32 May LG, Kelly JR. Influence of resin cement polymerization shrinkage on stresses in porcelain crowns. Dent Mater 2013; 29 (10) 1073-1079
  • 33 Scherrer SS, Cesar PF, Swain MV. Direct comparison of the bond strength results of the different test methods: a critical literature review. Dent Mater 2010; 26 (02) e78-e93
  • 34 Özcan M, Kojima AN, Nishioka RS, Mesquita AM, Bottino MA, Filho GD. Effect of jig design and assessment of stress distribution in testing metal-ceramic adhesion. J Prosthodont 2016; 25 (08) 665-669
  • 35 Placido E, Meira JB, Lima RG, Muench A, de Souza RM, Ballester RY. Shear versus micro-shear bond strength test: a finite element stress analysis. Dent Mater 2007; 23 (09) 1086-1092
  • 36 Ergin ES, Soygun K, Aygun EB, Kurtoglu C. The effect of different blade designs on shear bond strength of veneering ceramics fused to zirconia. J Australian Ceramic Soc 2021; 57 (05) 1463-1470
  • 37 Sebben J, Canevese VA, Alessandretti R. et al. Effect of surface coating on bond strength between etched feldspar ceramic and resin-based luting agents. BioMed Res Int 2018; 2018: 3039251
  • 38 Klaisiri A, Krajangta N, Thamrongananskul N. The durability of zirconia/resin composite shear bond strength using different functional monomer of universal adhesives. Eur J Dent 2022; 16 (04) 756-760
  • 39 Al-Ali AMAH, Khalifa N, Hadj-Hamou A, Sheela S, El-Damanhoury HM. Effect of thickness and bonding technique on fatigue and fracture resistance of feldspathic ultra-thin laminate veneers. Eur J Dent 2023; 17 (02) 431-438

Zoom Image
Fig. 1 Stereomicroscope analyses to standardize the thickness cement of the groups under magnification of 24.5 × . (A) 300 μm group, (B) 60 μm group.
Zoom Image
Fig. 2 Cementation process with a perforated matrix. (A) Isolated surface etching with hydrofluoric acid 5%. (B) Silane applying with the aid of a microbrush. (C) Cementation of the resin cylinders using static loading.
Zoom Image
Fig. 3 Topography micrographs of ceramic under 2000× magnification. (A) Polished ceramic. (B) Acid etched ceramic.
Zoom Image
Fig. 4 (A) Monotonic test and (B) fatigue test device.
Zoom Image
Fig. 5 Failure type under 50 X magnification. (A) Adhesive failure in the 300-μm group. (B) Mixed ceramic failure in the 300-μm group. (C) Adhesive failure in the 60-μm group. (D) Mixed ceramic failure in the 60-μm group. C, ceramic; CE, cement; AS, adhesive surface.
Zoom Image
Fig. 6 Survival plot using the Kaplan–Meier method, average and median strength of samples during the fatigue test.
Zoom Image
Fig. 7 Reliability plot showing that samples will fail as the time under fatigue increases in both groups. The Weibull modulus (β) and characteristic life (η) for 300 and 60 µm groups were respectively: β = 3.2 and 3.3 and η = 94,000 and 90,000 cycles.
Zoom Image
Fig. 8 Type of failure data of each group (%) regarding the scanning electron microscope (SEM) analysis.