Endoscopy 2017; 49(S 01): E103-E104
DOI: 10.1055/s-0043-100626
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Minimal incision-assisted full-thickness sampling with over-the-scope clip targeting intestinal neuronal malformation

Noriko Nishiyama
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Hirohito Mori
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Hideki Kobara
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Shintaro Fujihara
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Maki Ayaki
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Yumi Miyai
2   Department of Diagnostic Pathology, Faculty of Medicine, Kagawa University, Kagawa, Japan
,
Tsutomu Masaki
1   Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa, Japan
› Institutsangaben
Weitere Informationen

Corresponding author

Noriko Nishiyama, MD, PhD
Department of Gastroenterology and Neurology
Faculty of Medicine, Kagawa University
1750-1 Ikenobe
Miki, Kita
Kagawa 761-0793
Japan   
Fax: +81-87-8912158   

Publikationsverlauf

Publikationsdatum:
13. Februar 2017 (online)

 

Intestinal neuronal malformation (INM) is a rare and refractory pediatric disease [1]. Its definitive diagnosis is generally confirmed by an invasive full-thickness biopsy [2]. This biopsy is required because the nerve plexus is located in the deep submucosal and muscle layers, resulting in poor diagnostic ability with endoscopic suction biopsies [3]. In our experience, even specimens obtained by endoscopic submucosal dissection fail to provide an accurate histological evaluation owing to the burn effects. As a result, full-thickness specimens must be obtained to make a diagnosis of INM.

A new type of over-the-scope clip (OTSC), called a full-thickness resection device (FTRD; Ovesco Endoscopy, Tübingen, Germany), provides a moderate rate (75 %) of histologically complete resection, so indicating a need to modify procedures [4] [5]. In this animal study, we introduced a productive endoscopic full-thickness sampling method with the original OTSC system targeting INM.

A flexible gastrointestinal endoscope was used. First, a 10-mm mucosal pocket was created in the lower rectum using a needle knife (KD-650Q; Olympus, Tokyo, Japan) until the muscle layer was visible ([Fig. 1 a]). Next, after the artificial pocket had been anchored into the application cap with a retraction device (Anchor; Ovesco Endoscopy) that captured the exposed muscle layer, the OTSC was successfully deployed ([Fig. 1 b]). A 10-mm incision was then made with the needle knife in the muscle layer immediately above the clip to prevent slippage of the snaring device. Finally, a full-thickness resection was completed with the snare, without complications, using the Endo Cut Q mode on an electric generator (VIO300D; ERBE, Tübingen, Germany) ([Fig. 1 c, d]; [Video 1]).

Zoom Image
Fig. 1 Endoscopic images showing: a a 10-mm pocket with the muscle layer exposed that was created with a needle knife; b successful over-the-scope clip (OTSC) deployment with an anchor assist that captured the exposed muscle layer of the pocket; c complete full-thickness resection using a snare after a 10-mm incision had been made in the muscle layer immediately above the clip to prevent slippage of the snare; d a full-thickness defect that was closed by deployment of the OTSC.
Video 1: A full-thickness specimen is needed for the definitive diagnosis of intestinal neuronal malformation (INM). This video shows that the minimal incision-assisted over-the-scope clip (OTSC) procedure is simple, and is suitable for sampling a sufficient full-thickness specimen to allow a minimally invasive diagnosis of INM.

Qualität:

A 10-mm specimen with a sufficient muscle layer was acquired ([Fig. 2]). Histological examination revealed an adequate full-thickness layer including the myenteric plexus and ganglia cells ([Fig. 3]). This study emphasizes that a minimal incision-assisted OTSC procedure can facilitate full-thickness sampling and minimally invasive diagnosis of INM.

Zoom Image
Fig. 2 Macroscopic view showing the full-thickness resected specimen with a sufficient amount of muscle layer.
Zoom Image
Fig. 3 Histology of the specimen stained with hematoxylin and eosin (H&E) showing the full-thickness layers with the presence of the internal circular and external longitudinal muscle layers, and the neurogenic plexus containing ganglia cells (yellow arrows).


Endoscopy_UCTN_Code_TTT_1AO_2AC


#

Competing interests

None

  • References

  • 1 Qadir I, Salick MM, Barakzai A. et al. Isolated adult hypoganglionosis presenting as sigmoid volvulus: a case report. J Med Case Rep 2011; 5: 1
  • 2 Kobayashi H, Yamataka A, Lane GJ. et al. Pathophysiology of hypoganglionosis. J Pediatr Gastroenterol Nutr 2002; 34: 231-232
  • 3 Yunis EJ, Dibbins AW, Sherman FE. Rectal suction biopsy in the diagnosis of Hirschsprung disease in infants. Arch Pathol Lab Med 1976; 100: 329-333
  • 4 Snauwaert C, Jouret-Mourin A, Piessevaux H. Endoscopic full-thickness resection of a nonlifting adenoma in an ileal pouch using an over-the-scope full-thickness resection device. Endoscopy 2015; 47: E344-E345
  • 5 Schmidt A, Bauerfeind P, Gubler C. et al. Endoscopic full-thickness resection in the colorectum with a novel over-the-scope device: first experience. Endoscopy 2015; 47: 719-725

Corresponding author

Noriko Nishiyama, MD, PhD
Department of Gastroenterology and Neurology
Faculty of Medicine, Kagawa University
1750-1 Ikenobe
Miki, Kita
Kagawa 761-0793
Japan   
Fax: +81-87-8912158   

  • References

  • 1 Qadir I, Salick MM, Barakzai A. et al. Isolated adult hypoganglionosis presenting as sigmoid volvulus: a case report. J Med Case Rep 2011; 5: 1
  • 2 Kobayashi H, Yamataka A, Lane GJ. et al. Pathophysiology of hypoganglionosis. J Pediatr Gastroenterol Nutr 2002; 34: 231-232
  • 3 Yunis EJ, Dibbins AW, Sherman FE. Rectal suction biopsy in the diagnosis of Hirschsprung disease in infants. Arch Pathol Lab Med 1976; 100: 329-333
  • 4 Snauwaert C, Jouret-Mourin A, Piessevaux H. Endoscopic full-thickness resection of a nonlifting adenoma in an ileal pouch using an over-the-scope full-thickness resection device. Endoscopy 2015; 47: E344-E345
  • 5 Schmidt A, Bauerfeind P, Gubler C. et al. Endoscopic full-thickness resection in the colorectum with a novel over-the-scope device: first experience. Endoscopy 2015; 47: 719-725

Zoom Image
Fig. 1 Endoscopic images showing: a a 10-mm pocket with the muscle layer exposed that was created with a needle knife; b successful over-the-scope clip (OTSC) deployment with an anchor assist that captured the exposed muscle layer of the pocket; c complete full-thickness resection using a snare after a 10-mm incision had been made in the muscle layer immediately above the clip to prevent slippage of the snare; d a full-thickness defect that was closed by deployment of the OTSC.
Zoom Image
Fig. 2 Macroscopic view showing the full-thickness resected specimen with a sufficient amount of muscle layer.
Zoom Image
Fig. 3 Histology of the specimen stained with hematoxylin and eosin (H&E) showing the full-thickness layers with the presence of the internal circular and external longitudinal muscle layers, and the neurogenic plexus containing ganglia cells (yellow arrows).