The Journal of Hip Surgery
DOI: 10.1055/s-0044-1782513
Case Report

Periprosthetic Hip Heterotopic Ossification after Electrocution

1   Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, Massachusetts
,
Kurt V. Johnson
1   Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, Massachusetts
,
Olivia Bono
2   Harvard Combined Orthopaedic Residency Program, Boston, Massachusetts
,
James V. Bono
1   Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, Massachusetts
› Author Affiliations

Abstract

Background Heterotopic ossification is not only a common occurrence following total hip arthroplasty, but also may follow burn injuries. Uncommonly, this entity may become symptomatic when associated with a hip replacement and even less commonly presents in a delayed fashion years after the procedure.

Case Presentation We describe a case in which symptomatic periprosthetic heterotopic ossification was identified years after total hip replacement, but only months following an electrical injury.

Conclusion Patients with prosthetic joint replacements may be at risk for symptomatic periprosthetic heterotopic ossification following an electrocution event due to electrical conduction through the prosthesis and surrounding tissues.



Publication History

Received: 10 April 2023

Accepted: 05 February 2024

Article published online:
10 May 2024

© 2024. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Balboni TA, Gobezie R, Mamon HJ. Heterotopic ossification: pathophysiology, clinical features, and the role of radiotherapy for prophylaxis. Int J Radiat Oncol Biol Phys 2006; 65 (05) 1289-1299
  • 2 Padgett DE. Heterotopic ossification. In: Bono JV, McCarthy JC, Thornhill TS, Bierbaum BE, Turner RH. eds. Revision Total Hip Arthroplasty. New York: Springer; 1999: 464-474
  • 3 Board TN, Karva A, Board RE, Gambhir AK, Porter ML. The prophylaxis and treatment of heterotopic ossification following lower limb arthroplasty. J Bone Joint Surg Br 2007; 89 (04) 434-440
  • 4 Wilkinson JM, Stockley I, Hamer AJ, Barrington NA, Eastell R. Biochemical markers of bone turnover and development of heterotopic ossification after total hip arthroplasty. J Orthop Res 2003; 21 (03) 529-534
  • 5 Orzel JA, Rudd TG. Heterotopic bone formation: clinical, laboratory, and imaging correlation. J Nucl Med 1985; 26 (02) 125-132
  • 6 Balen PF, Helms CA. Bony ankylosis following thermal and electrical injury. Skeletal Radiol 2001; 30 (07) 393-397
  • 7 Evans EB. Orthopedic measures in the treatment of severe burns. J Trauma 1981; 28: 684-689
  • 8 Evans EB. Heterotopic bone formation in thermal burns. Clin Orthop Relat Res 1991; (263) 94-101
  • 9 Harwin SF. Trochanteric heterotopic ossification after total hip arthroplasty performed using a direct lateral approach. J Arthroplasty 2005; 20 (04) 467-472
  • 10 Pohl F, Seufert J, Tauscher A. et al. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty. Strahlenther Onkol 2005; 181 (08) 529-533
  • 11 Lo TC, Healy WL, Covall DJ. et al. Heterotopic bone formation after hip surgery: prevention with single-dose postoperative hip irradiation. Radiology 1988; 168 (03) 851-854
  • 12 Aboulafia AJ, Brooks F, Piratzky J, Weiss S. Osteosarcoma arising from heterotopic ossification after an electrical burn. A case report. J Bone Joint Surg Am 1999; 81 (04) 564-570