RSS-Feed abonnieren
DOI: 10.1055/s-0044-1796640
The Rotator Interval Bursa (RIB) Technique: Sequential Rotator Interval and Subacromial Subdeltoid Bursa Injection
Abstract
Shoulder pain is a common and increasing indication for patients being referred for pain relief injections. To address this, patients are offered corticosteroid injections for the glenohumeral joint as well as the subacromial subdeltoid (SASD) bursa under ultrasound guidance, which allows direct visualization of the needle and target structures with a more confident and real-time needle placement. We demonstrate a new technique, the rotator interval bursa (RIB) technique, of sequential injection of the glenohumeral joint targeting the rotator interval as well as the SASD bursa via the anterior approach with a single prick.
#
Keywords
ultrasound - shoulder pain - anterior approach - RIB technique - corticosteroid injection - rotator interval - subacromial-subdeltoid bursaIntroduction
Shoulder pain is a common and ever-increasing indication for patients being referred for pain relief injections. The common causes include osteoarthritis, impingement syndromes leading to rotator cuff pathologies, and adhesive capsulitis. In many instances, the clinical and radiological findings indicate the coexistence of multiple factors that may generate pain. Hence, patients are offered steroid injections for the glenohumeral joint as well as the subacromial subdeltoid (SASD) bursa to address these issues,[1] and combinations of injections have been documented to be more effective.[2]
Ultrasound guidance scores over fluoroscopy as it allows direct visualization of the needle along with soft tissue structures with greater confidence and accurate needle placement.[3]
Traditionally, glenohumeral joint injection is performed under ultrasonography guidance via a posterior approach, with the infraspinatus as an acoustic window.[4] The anterior approach of injecting the rotator interval (RI) has also been described and is preferred by some authors, especially in cases of adhesive capsulitis, as it is widely accepted that the RI is often the site of origin of pathology. The SASD bursa, which is a superficial structure, is injected via the anterior or posterior approach depending on the operator and patient comfort.[5]
A recent technique of injecting both sites sequentially via a single prick has been described by Shirodkar et al, who used a posterior approach.[6]
The authors describe another technique of sequential injection of the glenohumeral joint targeting the RI as well as the SASD bursa via the anterior approach.
#
Technique
We describe a simple new technique to target the RI as well as the SASD bursa: the rotator interval bursa (RIB) technique ([Video 1]).
Video 1 Ultrasound video showing the rotator interval bursa - RIB technique used to target the rotator interval as well as the subacromial subdeltoid bursa.
Qualität:
-
The patient lies in a lateral decubitus or semi-reclining position with the affected shoulder facing the operator. Ultrasound was performed to mark the site of entry into the RI ([Fig. 1A]).
-
The site is prepared using standard aseptic precautions. Local anesthetic (lignocaine 2 or 1%) is injected into the subcutaneous tissues, and the SASD bursa and the needle (38 mm, 22 gauge) are advanced under ultrasound guidance from the lateral to the medial approach into the RI ([Fig. 1B]).
-
A small amount of lignocaine is injected into the RI to confirm correct needle placement.
-
The needle is left in place, and the syringe is exchanged with a preloaded syringe containing a mixture of 80 mg (2 mL) of triamcinolone, 4 mL of 1% lignocaine, and 4 mL of 0.25% bupivacaine ([Fig. 2A, B]).
-
Five milliliters of this cocktail are injected into the RI. In cases of adhesive capsulitis, if hydrodilatation is indicated, the syringe may be exchanged and 10 to 20 mL of saline is injected into the RI.
-
The needle is then withdrawn under guidance to reach the SASD bursa ([Fig. 2C, D]) overlying the supraspinatus tendon.
-
Once accurate needle positioning is confirmed, the remaining 5 mL of the mixture is injected into the SASD bursa, and the needle is withdrawn.
-
This procedure can also be done by injecting the bursa first, followed by injection into the RI along the same route. Staying medial to the RI ensures the injectate does not flow down the biceps tendon sheath.
-
The site of injection is covered with a small dressing.
-
Ultrasound of the posterior glenohumeral joint space can be performed as a final step to confirm distension of the joint capsule by the injectate ([Fig. 3]).
#
Conclusion
We found this technique to be simple and effective for administering steroids that target the RIB and the SASD bursa via a single prick. This ensures better patient comfort and satisfaction with good results. This approach may be used as an alternative to the GIBPS technique,[5] which uses a posterior approach for the same benefit.
#
#
Conflict of Interest
None declared.
The Name of the Department(s) and Institution(s) to Which the Work Should Be Attributed
MSK Radiology, Medanta-The Medicity Hospital, Gurugram, India.
Patient Consent
Written informed consent was obtained from the subject described in this report.
-
References
- 1 Skedros JG, Hunt KJ, Pitts TC. Variations in corticosteroid/anesthetic injections for painful shoulder conditions: comparisons among orthopaedic surgeons, rheumatologists, and physical medicine and primary-care physicians. BMC Musculoskelet Disord 2007; 8: 63
- 2 Hou Y, Zhang T, Liu W, Lu M, Wang Y. The effectiveness of ultrasound-guided subacromial-subdeltoid bursa combined with long head of the biceps tendon sheath corticosteroid injection for hemiplegic shoulder pain: a randomized controlled trial. Front Neurol 2022; 13: 899037
- 3 Molini L, Mariacher S, Bianchi S. US guided corticosteroid injection into the subacromial-subdeltoid bursa: technique and approach. J Ultrasound 2012; 15 (01) 61-68
- 4 Chen CP, Lew HL, Hsu CC. Ultrasound-guided glenohumeral joint injection using the posterior approach. Am J Phys Med Rehabil 2015; 94 (12) e117-e118
- 5 Pourcho AM, Colio SW, Hall MM. Ultrasound-guided interventional procedures about the shoulder: anatomy, indications, and techniques. Phys Med Rehabil Clin N Am 2016; 27 (03) 555-572
- 6 Shirodkar K, Sharma GK, Kaur P, Iyengar KP, Hussein M, Botchu R. GIBPS technique-a novel sequential technique of performing shoulder corticosteroid injections. J Ultrasound 2024; 27 (04) 969-972
Address for correspondence
Publikationsverlauf
Artikel online veröffentlicht:
11. Dezember 2024
© 2024. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Skedros JG, Hunt KJ, Pitts TC. Variations in corticosteroid/anesthetic injections for painful shoulder conditions: comparisons among orthopaedic surgeons, rheumatologists, and physical medicine and primary-care physicians. BMC Musculoskelet Disord 2007; 8: 63
- 2 Hou Y, Zhang T, Liu W, Lu M, Wang Y. The effectiveness of ultrasound-guided subacromial-subdeltoid bursa combined with long head of the biceps tendon sheath corticosteroid injection for hemiplegic shoulder pain: a randomized controlled trial. Front Neurol 2022; 13: 899037
- 3 Molini L, Mariacher S, Bianchi S. US guided corticosteroid injection into the subacromial-subdeltoid bursa: technique and approach. J Ultrasound 2012; 15 (01) 61-68
- 4 Chen CP, Lew HL, Hsu CC. Ultrasound-guided glenohumeral joint injection using the posterior approach. Am J Phys Med Rehabil 2015; 94 (12) e117-e118
- 5 Pourcho AM, Colio SW, Hall MM. Ultrasound-guided interventional procedures about the shoulder: anatomy, indications, and techniques. Phys Med Rehabil Clin N Am 2016; 27 (03) 555-572
- 6 Shirodkar K, Sharma GK, Kaur P, Iyengar KP, Hussein M, Botchu R. GIBPS technique-a novel sequential technique of performing shoulder corticosteroid injections. J Ultrasound 2024; 27 (04) 969-972