Journal of Reconstructive Microsurgery, Table of Contents J Reconstr Microsurg 2002; 18(2): 137-140DOI: 10.1055/s-2002-19896 CLINICAL REVIEW Copyright © 2002 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662 Invited Discussion Jamie P. Levine1 , Christina Y. Ahn1 1Institute of Reconstructive Plastic Surgery, NYU Medical Center, New York, NY Recommend Article Abstract Buy Article Full Text References REFERENCES 1 Imola M J, Hamlar D D, Shao W. Resorbable plate fixation in pediatric craniofacial surgery: long-term outcome. Arch Facial Plast Surg . 2001; 3 79-90 2 Kaiser A M, Corman M L, History of laparoscopy. Surg Oncol Clin N Am . 2001; 10 483-492 3 Ahn C Y, Shaw W W, Berns S, Markowitz B L. Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers. Plast Reconstr Surg . 1994; 93 1481-1484 4 Denk M J, Longaker M T, Basner A L. Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses. Ann Plast Surg . 1995; 35 601-606 5 DeLacure M D, Kuriakose M A, Spies A L. Clinical experience in end-to-side venous anastomoses with a microvascular anastomotic coupling device in head and neck reconstruction. Arch Otolaryngol Head Neck Surg . 1999; 125 869-872 6 DeLacure M D, Wong R S, Markowitz B L. Clinical experience with a microvascular anastomotic device in head and neck reconstruction. Am J Surg . 1995; 170 521-523 7 Zhang L, Kolker A R, Choe E I. Venous microanastomosis with the Unilink system, sleeve, and suture techniques: a comparative study in the rat. J Reconstr Microsurg . 1997; 13 257-262 8 Berggren A, Östrup L T, Lidman D. Mechanical anastomosis of small arteries and veins with the Unilink apparatus: a histologic and scanning electron microscopic study. Plast Reconstr Surg . 1987; 80 274-283 9 Berggren A, Östrup L T, Lidman D. Mechanical anastomosis of small arteries and veins with the Unilink apparatus: a histologic and scanning electron microscopic study. Plast Reconstr Surg . 1987; 80 274-283 10 Kind G M, Buncke G M, Buncke H J. Foreign-body sensation following 3M coupler use in the hand. Ann Plast Surg . 1996; 37 418-421 11 Gilbert R W, Ragnarsson R, Berggren A, Östrup L. Strength of microvascular anastomoses: comparison between the Unilink anastomotic system and sutures. Microsurgery . 1989; 10 40-46 12 Russell R C, Van B eek, Zook E G, Jacobs S C. The growth potential of small arteries repaired by microsurgical technique. Ann Plast Surg. 1986; 17 34-38