Subscribe to RSS
Please copy the URL and add it into your RSS Feed Reader.
https://www.thieme-connect.de/rss/thieme/en/10.1055-s-00000029.xml
J Reconstr Microsurg 1998; 14(6): 401-406
DOI: 10.1055/s-2007-1000199
DOI: 10.1055/s-2007-1000199
ORIGINAL ARTICLE
© 1998 by Thieme Medical Publishers, Inc.
Little Finger‐to‐Thumb Microvascular Transfer
Further Information
Publication History
Accepted for publication 1998
Publication Date:
08 March 2008 (online)
![](https://www.thieme-connect.de/media/jrm/199806/lookinside/thumbnails/10.1055-s-2007-1000199-1.jpg)
ABSTRACT
This case report documents a unique thumb reconstruction performed at the authors' institutions. The amputated dominant right thumb of a manual laborer was electively reconstructed with microvascular transfer of the previously partially amputated little finger from the same hand. At 1 year postopera-tively, the patient returned to work with excellent grip and pinch strength, thumb opposition to all digits, and 8 mm of static two-point discrimination. The technical details of the operation are described and compared with other analogous reports in the literature.