Abstract
Aim: A prospective long-term study of the first 250 cementless Bicontact stems implanted in the BG Trauma Centre, Tuebingen, Germany. Method: All of the patients in this series (treatment period June 1987 to April 1990) who were still contactable were invited for clinical and radiological follow-up. The radiographs were analysed for signs of loosening in the form of Gruen lysis zones, stress shielding, subsidence behaviour, heterotopic ossification and spot welds. Results: The average follow-up period was 17.8 (16.7 - 19.5) years. The overall rate of follow-up was 65 % (162 of 250) and 91 % of patients who were still alive (162 of 179). The average patient age was 56.2 years at the time of operation and 74.0 years at follow-up. The average HHS was 81.6 points. In the course of the first 10 years (up to 03/1998), a total of 8 stem revisions had to be performed. In the period from 03/1998 to 01/2007, 2 cases of loosening requiring revision occurred in the patients still alive at the time of follow-up. The survival rate calculated was thus 95.6 %. Conclusion: These outstanding results provide enduring support for the philosophy of the cementless and bone-preserving fixation principles underlying the Bicontact hip stem with proximal intertrochanteric transmission of forces and high primary rotational stability.
Key words
total hip arthroplasty - cementless - proximal fixation - long‐term results
References
-
1
Acklin Y P, Berli B J, Frick W, Elke R, Morscher E W.
Nine-year results of Muller cemented titanium straight stems in total hip replacement.
Arch Orthop Trauma Surg.
2001;
121
391-398
-
2
Aldinger P R, Thomsen M, Mau H, Ewerbeck V, Breusch S J.
Cementless spotorno titanium stems: excellent 10 - 15-year survival in 141 young patients.
Acta Orth Scand.
2003;
74
253-258
-
3
Aldinger P R, Breusch S J, Lukoschek M, Mau H, Ewerbeck V, Thomsen M.
A ten- to 15-year follow-up of the cementless spotorno stem.
J Bone Joint Surg [Br].
2003;
85
209-214
-
4
Archibeck M J, Berger R A, Quigley L R, Gitelis S, Rosenberg A G, Galante J.
Second-generation cementless total hip arthroplasty. Eight to eleven year results.
J Bone Joint Surg.
2001 [Am];
83
1666-1673
-
5
Biedermann R, Krismer M, Stöckl B, Mayrhofer P, Ornstein E, Franzen H.
Accuracy of EBRA‐FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse - femoral component analysis.
J Bone Joint Surg [Br].
1999;
81
266-272
-
6
Bobyn J D, Pilliar R M, Cameron H U, Weatherly G C.
The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone.
Clin Orthop.
1980;
150
263-270
-
7
Brooker A F, Bowerman J W, Robinson R A, Riley L H.
Ectopic ossifications following total hip replacement, incidence and a method of classification.
J Bone Joint Surg [Am].
1973;
55
1629-1632
-
8
Callaghan J J, Albright J C, Goetz D D, Olejniczak J P, Johnston R C.
Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up.
J Bone Joint Surg [Am].
2000;
82
487-497
-
9
Chlohishi J C, Harris W H.
The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years.
J Arthroplasty.
1999;
14
915-917
-
10
D'Antonio J A, Capello W N, Manley M T, Geesink R G.
Hydroxyapatite femoral stems for total hip arthroplasty.
Clin Orthop.
2001;
393
101-111
-
11
Dobbs H S.
Survivorship of total hip replacement.
J Bone Joint Surg [Br].
1980;
62
168-173
-
12
Duffy G P, Berry D J, Rowland C, Cabanela M E.
Primary uncemented total hip arthroplasty in patients < 40 years old: 10- to 14-year results using first-generation proximally porous-coated implants.
J Arthroplasty.
2001;
16
140-144
-
13
Eingartner C, Volkmann R, Heigele D, Weise K.
Long-term results of an uncemented straight femoral shaft prosthesis.
Hip Int.
2006;
16
23-32
-
14
Eingartner C, Ilchmann T, Dieter J, Weise K.
Subsidence pattern of a cementless straight titanium femoral stem - a radiographic study with EBRA‐FCA.
Hip International.
2005;
15
85-91
-
15 Eingartner C, Volkmann R, Ilchmann T, Weise K, Weller S. A modular system for cemented and uncemented implantation of femoral stem prostheses. Szabo, Lewis, Fantini, Savalgi Surgical Technology International. San Francisco; Universal Medical Press 1998: 353-360
-
16
Eingartner C, Volkmann R, Winter E, Maurer F, Sauer G, Weller S, Weise K.
Results of an uncemented straight femoral shaft prosthesis after 9 years of follow-up.
J Arthroplasty.
2000;
15
440-447
-
17
Engh C A, Bobyn J D, Glassman A H.
Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding and clinical results.
J Bone Joint Surg [Br].
1987;
69
45-55
-
18
Engh C A, Claus A M, Hopper R H, Engh C A.
Long-term results using the anatomic medullary locking hip prosthesis.
Clin Orthop.
2001;
393
137-146
-
19
Engh C A, Massin P, Suthers K E.
Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.
Clin Orthop.
1990;
257
107-128
-
20
Engh Jr C A, Culepper W J, Engh C A.
Long-term results of use of the anatomic medullary locking prosthesis in total hip replacement.
J Bone Joint Surg [Am].
1997;
79
177-184
-
21
Evans B G, Salvati E A, Huo M H, Huk O L.
The rationale for cemented total hip arthroplasty.
Orthop Clin North Am.
1993;
24
599-610
-
22
Gruen T A, McNeice G M, Amstutz H C.
“Modes of failure” of cemented stem-type femoral components.
Clin Orthop.
1979;
141
17-27
-
23
Harris W.
Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by arthroplasty. An end-result study using a new method of result-evaluation.
J Bone Joint Surg [Am].
1969;
51
737-755
-
24
Hellmann E J, Capello W N, Feinberg J R.
Omnifit cementless total hip arthroplasty - a 10-year average follow-up.
Clin Orthop.
1999;
364
164-174
-
25
Huggler A H, Jacob H A, Bereiter H, Haverkorn M, Ryf C, Schenk R.
Long-term results with the uncemented thrust plate prosthesis (TPP).
Acta Orthop Belg.
1993;
59 (Suppl 1)
215-223
-
26
Johnston R C, Fitzgerald R H, Harris W H, Poss R, Müller M E, Sledge C B.
Clinical and radiographic evaluation of total hip replacement.
J Bone Joint Surg [Am].
1990;
72
161-168
-
27
Jones L C, Hungerford D S.
Cement disease.
Clin Orthop.
1987;
225
192-206
-
28
Kawamura M, Dunbar M J, Murray P, Bourne R B, Rorabeck C H.
The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty.
J Bone Joint Surg [Am].
2001;
83
1333-1338
-
29
Keisu K S, Mathiesen E B, Lindgren J U.
The uncemented fully textured Lord hip prosthesis: a 10- to 15-year follow-up study.
Clin Orthop.
2001;
382
133-142
-
30
Kim Y H, Kim J S, Cho S H.
Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series.
J Arthroplasty.
1999;
14
538-548
-
31
Knahr K, Kryspin-Exner I, Jagsch R, Freilinger W, Kasparek M.
[Evaluating the quality of life before and after implantation of a total hip endoprosthesis] Beurteilung der Lebensqualität vor und nach Implantation einer Hüfttotalendoprothese.
Z Orthop Ihre Grenzgeb.
1998;
136
321-329
-
32
McLaughlin J R, Lee K R.
Total hip arthroplasty with an uncemented femoral component - excellent results at ten-year follow-up.
J Bone Joint Surg [Br].
1997;
79
900-907
-
33
McLaughlin J R, Lee K R.
Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem.
Clin Orthop.
2000;
373
153-163
-
34
Murray D W, Britton A R, Bulstrode C J.
Loss to follow-up matters.
J Bone Joint Surg [Br].
1997;
79
254-257
-
35
Murray D W, Carr A J, Bulstrode C J.
Survival analysis of joint replacements.
J Bone Joint Surg [Br].
1993;
75
697-704
-
36
Oishi C S, Walker R H, Colwell C WJ.
The femoral component in total hip arthroplasty. Six to eight year follow-up of one hundred consecutive patients after use of a third-generation cementing technique.
J Bone Joint Surg [Am].
1994;
76
1130-1136
-
37
Rothman K J.
Estimation of confidence limits for the cumulative probability of survival in life table analysis.
J Chron Dis.
1978;
31
557-560
-
38
Sakalkale D P, Eng K, Hozak W J, Rothman R H.
Minimum 10-year results of a tapered cementless hip replacement.
Clin Orthop.
1999;
362
138-144
-
39
Schramm M, Keck F, Hohmann D, Pitto R P.
Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up.
Arch Orthop Trauma Surg.
2000;
120
407-412
-
40
Siebold R, Scheller G, Schreiner U, Jani L.
[Long-term results with the cement-free Spotorno CLS shaft] Langzeitergebnisse mit dem zementfreien CLS-Schaft von Spotorno.
Orthopäde.
2001;
30
317-322
-
41
Simanek H G, Brocai D RC, Reiser D, Thomsen M, Sabo D, Lukoschek M.
Middle term results of threaded acetabular cups.
J Bone Joint Surg [Br].
1997;
79
366-370
-
42
Volkmann R, Eingartner C, Winter E, Weise K, Weller S.
Mid term results in 500 titanium alloy straight femoral shaft prostheses - cemented and cementless technique.
Eur J Orthop Surg Traumatol.
1998;
8
133-139
-
43
Xenos J S, Callaghan J J, Heekin R D, Hopkinson W J, Savory C G, Moore M S.
The porous-coated anatomic total hip prosthesis, inserted without cement - a prospective study with a minimum of ten years of follow-up.
J Bone Joint Surg [Am].
1999;
81
74-82
-
44
Yahiro M A, Gantenberg J B, Nelson R, Lu H TC, Mishra N K.
Comparison of the results of cemented, porous-ingrowth, and threaded acetabular cup fixation.
J Arthroplasty.
1995;
10
339-350
-
45
Zenz P, Pospisil C, Fertschak W, Schwägerl W.
[10 years of cementless implantation of total hip endoprosthesis using Zweymuller's stem] 10 Jahre zementfreie Implantation von Hüfttotalendoprothesen unter Verwendung des Zweymüller-Schaftes.
Z Orthop.
1995;
133
558-561
Dr. MD Uwe Ochs
Berufsgenossenschaftliche Unfallklinik
Schnarrenbergstr. 95
72076 Tuebingen
Germany
Phone: + 49 70 71 6 06 11 67
Fax: + 49 70 71 6 06 10 02
Email: uochs@bgu-tuebingen.de