Subscribe to RSS
DOI: 10.1055/s-2007-966978
© Georg Thieme Verlag KG Stuttgart · New York
Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention
Publication History
submitted 26 March 2007
accepted after revision 30 July 2007
Publication Date:
10 December 2007 (online)
Background and study aims: Although capsule endoscopy has become a central diagnostic tool for small-bowel evaluation, retention of a capsule remains a major concern. This study attempted to investigate the incidence and clinical outcomes of capsule retention, and to determine the factors predictive of spontaneous capsule passage after retention.
Patients and methods: Through a nationwide multicenter survey, we retrospectively reviewed the records of 1291 patients who had a capsule endoscopy between February 2002 and July 2006 in Korea. Clinical and procedural characteristics and postprocedural outcomes were analyzed for the cases with capsule retention.
Results: Capsule retention occurred in 2.5 % of total cases (32/1291). The major diseases accompanying capsule retention were Crohn’s disease, malignant tumors, and tuberculous enterocolitis, in decreasing order. In 11 of the 32 patients (34.4 %), early surgical or endoscopic interventions were instituted for diagnosis or treatment of diseases before retention symptoms developed. The remaining 21 (65.6 %) patients initially received medical treatments. Of these, 10 (31.3 %) ultimately underwent surgical intervention due to the development of symptoms of intestinal obstruction or medical treatment failure. The other 11 (34.4 %) eventually passed the capsule. The presence of a larger lumen diameter (greater than two-thirds of the capsule diameter) at the stricture site was associated with spontaneous passage.
Conclusions: Our large-scale study suggests that retention occurs infrequently during capsule endoscopy. Moreover, a retained capsule might indicate the best intervention for the offending pathology, or it may spontaneously pass in the long run, particularly in patients with less small bowel stricture.
References
- 1 Swain P, Adler D, Enns R. Capsule endoscopy in obscure intestinal bleeding. Endoscopy. 2005; 37 655-659
- 2 Scapa E, Jacob H, Lewkowicz S. et al . Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology. Am J Gastroenterol. 2002; 97 2776-2779
- 3 Fireman Z, Mahajna E, Broide E. et al . Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy. Gut. 2003; 52 390-392
- 4 Shim K N, Kim Y S, Kim K J. et al . Abdominal pain accompanied by weight loss may increase the diagnostic yield of capsule endoscopy: a Korean multicenter study. Scand J Gastroenterol. 2006; 41 983-988
- 5 Fry L C, Carey E J, Shiff A D. et al . The yield of capsule endoscopy in patients with abdominal pain or diarrhea. Endoscopy. 2006; 38 498-502
- 6 Cave D, Legnani P, de Franchis R. et al . ICCE consensus for capsule retention. Endoscopy. 2005; 37 1065-1067
- 7 Pennazio M, Santucci R, Rondonotti E. et al . Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterology. 2004; 126 643-653
- 8 Buchman A L, Miller F H, Wallin A. et al . Videocapsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine. Am J Gastroenterol. 2004; 99 2171-2177
- 9 Cheifetz A S, Kornbluth A A, Legnani P. et al . The risk of retention of the capsule endoscope in patients with known or suspected Crohn’s disease. Am J Gastroenterol. 2006; 101 2218-2222
- 10 Cheifetz A S, Lewis B S. Capsule endoscopy retention: is it a complication?. J Clin Gastroenterol. 2006; 40 688-691
- 11 Baichi M M, Arifuddin R M, Mantry P S. What we have learned from 5 cases of permanent capsule retention. Gastrointest Endosc. 2006; 64 283-287
- 12 Rondonotti E, Herrerias J M, Pennazio M, Caunedo A, Mascarenhas-Saraiva M, de Franchis R. Complications, limitations, and failures of capsule endoscopy: a review of 733 cases. Gastrointest Endosc. 2005; 62 712-716
- 13 Lewis B. How to prevent endoscopic capsule retention. Endoscopy. 2005; 37 852-856
- 14 Sears D M, Avots-Avotins A, Culp K, Gavin M W. Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin. Gastrointest Endosc. 2004; 60 822-827
- 15 Yang S K, Loftus E V, Sandborn W J. Epidemiology of inflammatory bowel disease in Asia. Inflamm Bowel Dis. 2001; 7 260-270
- 16 Kim S G, Kim J S, Jung H C, Song I S. Is a 9-month treatment sufficient in tuberculous enterocolitis? A prospective, randomized, single-centre study. Aliment Pharmacol Ther. 2003; 18 85-91
- 17 Tandon H D, Prakash A. Pathology of intestinal tuberculosis and its distinction from Crohn’s disease. Gut. 1972; 13 260-269
- 18 Barkin J S, Friedman S. Wireless capsule endoscopy requiring surgical intervention. The world’s experience. Am J Gastroenterol. 2002; 97 83
- 19 Aberra F N, Lewis J D, Hass D, Rombeau J L, Osborne B, Lichtenstein G R. Corticosteroids and immunomodulators: postoperative infectious complication risk in inflammatory bowel disease patients. Gastroenterology. 2003; 125 320-327
- 20 Subramanian V, Pollok R C, Kang J Y, Kumar D. Systematic review of postoperative complications in patients with inflammatory bowel disease treated with immunomodulators. Br J Surg. 2006; 93 793-799
- 21 Spada C, Spera G, Riccioni M. et al . A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule. Endoscopy. 2005; 37 793-800
- 22 Boivin M L, Lochs H, Voderholzer W A. Does passage of a patency capsule indicate small-bowel patency? A prospective clinical trial. Endoscopy. 2005; 37 808-815
- 23 Signorelli C, Rondonotti E, Villa F. et al . Use of the Given patency system for the screening of patients at high risk for capsule retention. Dig Liver Dis. 2006; 38 326-330
- 24 Voderholzer W A, Beinhoelzl J, Rogalla P. et al . Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut. 2005; 54 369-373
D. K. Chang, MD, PhD
Division of Gastroenterology
Department of Medicine
Sungkyunkwan University School of Medicine
Samsung Medical Center
50 Irwon-dong
Gangnam-gu
Seoul 135-710
Korea
Fax: +82-2-34103849
Email: dkchang@skku.edu