Minim Invasive Neurosurg 2007; 50(3): 186-190
DOI: 10.1055/s-2007-982511
Technical Note

© Georg Thieme Verlag KG Stuttgart · New York

Minimally Invasive Technique for Direct Repair of the Pars Defects in Young Adults using a Spinal Endoscope: A Technical Note

K. Higashino 1 , K. Sairyo 1 , S. Katoh 1 , T. Sakai 1 , H. Kosaka 1 , N. Yasui 1
  • 1Department of Orthopedics, The University of Tokushima, Tokushima, Japan
Further Information

Publication History

Publication Date:
19 September 2007 (online)

Abstract

Pars defect (spondylolysis) of the lumbar spine can cause chronic low back pain, and it sometimes requires surgical intervention. Direct repair is selected for the surgery if young adult patients do not present significant disc degeneration and lumbar instability. In order to lessen damages of back muscles during surgery, we added the use of a spinal endoscope to the “Buck's screwing procedure” the direct repair. There are four steps in this procedure: 1) identification of the defect, 2) curettage (refresh) of the defect, 3) percutaneous insertion of the annulated screws and 4) cancellous bone grafting. All these steps can be done endoscopically. We treated 3 young adults - a baseball player, a professional cycle-racer and a sculptor - using this endoscopic procedure. There were no complications during or after the operation. Union was obtained in all defects within 3 months, and they returned to their previous activities within 6 months after the surgery.

References

  • 1 Fredrickson BE, Baker D, MacHolick WJ, Yuan HA. et al . The natural history of spondylolysis and spondylolisthesis.  J Bone Joint Surg [Am]. 1984;  66 699-707
  • 2 Bonnici AV, Koka SR, Richards DJ. Results of Buck screw fusion in grade I spondylolisthesis.  J Roy Soc Med. 1991;  84 270-273
  • 3 Buck JE. Direct repair of the defect in spondylolisthesis. Preliminary report.  J Bone Joint Surg [Br]. 1970;  52 432-437
  • 4 Buck J. Further thoughts on direct repair of the defect in spondylolysis.  J Bone Joint Surg [Br]. 1979;  61 123
  • 5 Nicol RO, Scott JH. Lytic spondylolysis. Repair by wiring.  Spine. 1986;  11 1027-1030
  • 6 Tokuhashi Y, Matsuzaki H. Repair of defects in spondylolysis by segmental pedicular screw hook fixation. A preliminary report.  Spine. 1996;  21 2041-2045
  • 7 Sairyo K, Katoh S, Sakamaki T. et al . Three successive stress fractures at the same vertebral level in an adolescent baseball player.  Am J Sports Med. 2003;  31 606-610
  • 8 Deguchi M, Rapoff AJ, Zdeblick TA. Biomechanical comparison of spondylolysis fixation techniques.  Spine. 1999;  24 328-333
  • 9 Faizan A, Sairyo K, Goel VK, Biyani S, Ebraheim N. Buck's direct repair of lumbar spondylolysis restores stresses at the involved and adjacent level disc. Transactions of the Orthopaedic Research Society, Chicago, IL March 19-22 2006
  • 10 Debnath UK, Freeman BJ, Gregory P, Harpe D de la, Kersiake RW, Webb JK. Clinical outcome and return to sport after the surgical treatment of spondylolysis in young athletes.  J Bone Joint Surg [Br]. 2003;  85 244-249
  • 11 Hardcastle PH. Repair of spondylolysis in young fast bowlers.  J Bone Joint Surg [Br]. 1993;  75 398-402
  • 12 Foley KT, Smith MM. Microendoscopic discectomy.  Tech Neurosurg. 1997;  3 301-307
  • 13 Kawaguchi Y, Matsui H, Tsuji H. Back muscle injury after posterior lumbar spine surgery. Part 1: Histologic and histochemical analyses in rats.  Spine. 1994;  19 2590-2597
  • 14 Kawaguchi Y, Matsui H, Tsuji H. Back muscle injury after posterior lumbar spine surgery. Part 2: Histologic and histochemical analyses in humans.  Spine. 1994;  19 2598-2602
  • 15 Huang TJ, Hsu RW, Li YY, Cheng CC. Less systemic cytokine response in patients following microendoscopic versus open lumbar discectomy.  J Orthop Res. 2005;  23 406-411
  • 16 Sasaoka R, Nakamura H, Konishi S. et al . Objective assessment of reduced invasiveness in MED compared with conventional one-level laminotomy.  Eur Spine J. 2005;  15 577-582
  • 17 Sairyo K, Goel VK, Masuda A. et al . Biomechanical rationale of endoscopic decompression for lumbar spondylolysis as an effective minimally invasive procedure - a study based on the finite element analysis.  Minim Invas Neurosurg. 2005;  48 119-122
  • 18 Ikawa M, Atsuta Y, Tsunekawa H, Matsuno T. Is MED less invasive than LOVE? Examination of the influence on PVM by using near infrared spectroscopy.  Jpn J Spine Research Society. 2004;  15 242 , [in Japanese]

Correspondence

K. SairyoMD, PhD 

Department of Orthopedics

Institute of Health Biosciences

The University of Tokushima Graduate School

3-18-15 Kuramoto

770-8503 Tokushima

Japan

Phone: +81/88/633 72 40

Fax: +81/88/633 01 78

Email: sairyokun@hotmail.com

Email: sairyo@clin.med.tokushima-u.ac.jp