Caval Penetration with Retroperitoneal Hemorrhage Following Placement of an Inferior Vena Cava (IVC) Filter
Publication History
Publication Date:
03 September 2007 (online)
ABSTRACT
Placement of inferior vena cava (IVC) filters is an increasingly common request at our institution. The rise in utilization of caval filtration is probably multifactorial and includes pulmonary embolism (PE) prophylaxis most notably in the setting of trauma, the approval and widespread use of temporary/removable filters, and the perceived low complication rates associated with new generation filter designs. We present a unique case of IVC penetration by a new generation filter that resulted in a retroperitoneal hemorrhage in a fully anticoagulated patient.
KEYWORDS
Vena cava filters - vena cava complications
REFERENCES
- 1 Teitelbaum G P, Jones D L, van Breda A et al.. Vena caval filter splaying: potential complication of use of the titanium Greenfield filter. Radiology. 1989; 173 809-814
- 2 Kalva S P, Athanasoulis C A, Fan C M et al.. “Recovery” vena cava filter: experience in 96 patients. Cardiovasc Intervent Radiol. 2006; 29 559-564
- 3 Kalva S P, Wicky S, Waltman A C et al.. TrapEase vena cava filter: experience in 751 patients. J Endovasc Ther. 2006; 13 365-372
- 4 Greenfield L J, Zocco J, Wilk J et al.. Clinical experience with the Kim-Ray Greenfield vena cava filter. Ann Surg. 1977; 185 692-698
- 5 Woodward E B, Farber A, Wagner W H et al.. Delayed retroperitoneal arterial hemorrhage after inferior vena cava (IVC) filter insertion: case report and literature review of caval perforations by IVC filters. Ann Vasc Surg. 2002; 16 193-196