Subscribe to RSS
DOI: 10.1055/s-2008-1077420
© Georg Thieme Verlag KG Stuttgart · New York
Latex hand glove: a safe and convenient device for the endoscopic removal of foreign bodies
S. Yoshida, MD, PhD
Department of Gastroenterology
Internal Medicine
TMG Asakadai Central General Hospital
1-8-10, Nishi-benzai
Asaka-shi
Saitama 351-8551
Japan
Fax: +81-48-4662735
Email: carcinogenesis@hotmail.com
Publication History
Publication Date:
15 August 2008 (online)
During the endoscopic removal of a sharp or pointed object from the upper gastrointestinal tract, both the pharyngoesophageal junction and the esophagogastric junction can be easily injured. The use of a latex protector hood and overtube has been previously reported as world-standard equipment [1] [2]. However, their costs are usually high. Furthermore, there is much patient distress associated with their use during the endoscopic examination. We therefore devised a new procedure.
The latex hand glove (LHG) is a basic necessity for every endoscopic examination. It is one of the reasonably priced endoscopic instruments ([Fig. 1]). However, the other intended use of LHG has not been previously reported. We herein describe the use of the LHG for the endoscopic removal of foreign bodies.
The LHG (Toray Medical Co., Ltd.; Cat.No. 8857SN) was used in the following way:
-
The finger part of the glove ([Fig. 2]) is cut out and firmly attached to the endoscope with vinyl tape ([Fig. 3]).
-
Straight grasping forceps are used as an endoscopic grasper of foreign bodies ([Fig. 4]).
-
When the endoscope is pulled back after grasping, the LHG is automatically reversed, and foreign bodies are enveloped within ([Fig. 5]). The sharp and pointed objects can then be safely removed while carefully protecting the gastrointestinal mucosa.
In our hospital, this procedure has sometimes been selected for the removal of foreign bodies. The procedure has been successful and has not caused any complications. In addition, the use of the LHG device has demonstrated a good cost performance. Neither the overtube nor the latex protector hood is needed during this procedure and it is therefore also less painful for patients. These results suggest that the LHG may therefore be a convenient, safe, and useful piece of equipment, and we recommend its use for the endoscopic removal of foreign bodies.
Endoscopy_UCTN_Code_TTT_1AO_2AL
#References
- 1 Smith M T, Wong R K. Esophageal foreign bodies: types and techniques for removal. Curr Treat Options Gastroenterol. 2006; 9 75-84
- 2 Bertoni G, Sassatelli R, Conigliaro R. et al . A simple latex protector hood for safe endoscopic removal of sharp-pointed gastroesophageal foreign bodies. Gastrointest Endosc. 1996; 44 458-461
S. Yoshida, MD, PhD
Department of Gastroenterology
Internal Medicine
TMG Asakadai Central General Hospital
1-8-10, Nishi-benzai
Asaka-shi
Saitama 351-8551
Japan
Fax: +81-48-4662735
Email: carcinogenesis@hotmail.com
References
- 1 Smith M T, Wong R K. Esophageal foreign bodies: types and techniques for removal. Curr Treat Options Gastroenterol. 2006; 9 75-84
- 2 Bertoni G, Sassatelli R, Conigliaro R. et al . A simple latex protector hood for safe endoscopic removal of sharp-pointed gastroesophageal foreign bodies. Gastrointest Endosc. 1996; 44 458-461
S. Yoshida, MD, PhD
Department of Gastroenterology
Internal Medicine
TMG Asakadai Central General Hospital
1-8-10, Nishi-benzai
Asaka-shi
Saitama 351-8551
Japan
Fax: +81-48-4662735
Email: carcinogenesis@hotmail.com