Yearbook of Medical Informatics, Inhaltsverzeichnis Yearb Med Inform 2016; 25(01): 159-162DOI: 10.15265/IY-2016-053 IMIA and Schattauer GmbH Georg Thieme Verlag KG StuttgartUnintended Consequences of Sensor, Signal, and Imaging Informatics: New Problems and New Solutions C. Hughes 1 Univ. Grenoble Alpes, INSERM, CIC 1406; CHU Grenoble, Pôle Recherche, Grenoble, France , S. Voros 2 Univ. Grenoble Alpes, CNRS, INSERM, TIMC-IMAG, Grenoble, France 4 Section Editors for the IMIA Yearbook Section on Sensor Signal and Imaging Informatics , A. Moreau-Gaudry 3 INSERM CIC 1406; Univ. Grenoble Alpes, CNRS, TIMC-IMAG; CHU de Grenoble, Pôle Santé Publique, Grenoble, France 4 Section Editors for the IMIA Yearbook Section on Sensor Signal and Imaging Informatics› InstitutsangabenArtikel empfehlen Abstract Volltext als PDF herunterladen Keywords KeywordsInnovative technology - unintended consequences - novel solutions Referenzen References 1 Brodoefel H, Bender B, Schabel C, Fenchel M, Ernemann U, Korn A. Potential of combining iterative reconstruction with noise efficient detector design: aggressive dose reduction in head CT.. Br J Radiol 2015; 88 1050 20140404. 2 Ha S, Mueller K. Low dose CT image restoration using a database of image patches.. Phys Med Biol 2015; 60 (Suppl. 02) 869-82. 3 Ferrante E, Fecamp V, Paragios N. Slice-to-volume deformable registration: efficient one-shot consensus between plane selection and in-plane deformation.. Int J Comput Assist Radiol Surg 2015; 10 (Suppl. 06) 791-800. 4 Brendle C, Schmidt H, Oergel A, Bezrukov I, Mueller M, Schraml C. et al. Segmentation-based attenuation correction in positron emission tomography/magnetic resonance: erroneous tissue identification and its impact on positron emission tomography interpretation.. Invest Radiol 2015; 50 (Suppl. 05) 339-46. 5 Du H, Ma R, Wang X, Zhang J, Fang J. Bas-Relief Map Using Texture Analysis with Application to Live Enhancement of Ultrasound Images.. Ultra-sound Med Biol 2015; 41 (Suppl. 05) 1446-60. 6 Liu C, van Netten JJ, van Baal JG, Bus SA, van der Heijden F. Automatic detection of diabetic foot complications with infrared thermography by asymmetric analysis.. J Biomed Opt 2015; 20 (Suppl. 02) 26003. 7 Chen Z, Strange H, Oliver A, Denton ER, Boggis C, Zwiggelaar R. Topological Modeling and Classification of Mammographic Microcalcification Clusters.. IEEE Trans Biomed Eng 2015; 62 (Suppl. 04) 1203-14. 8 Mert S, Özbek E, Ötünçtemur A, Çulha M.. Kidney tumor staging using surface-enhanced Raman scattering.. J Biomed Opt 2015; 20 (Suppl. 04) 47002. 9 Gooya A, Lekadir K, Alba X, Swift AJ, Wild JM, Frangi AF. Joint clustering and component analysis of correspondenceless point sets: application to cardiac statistical modeling.. In: Information Processing in Medical Imaging. Springer; 2015. p. 98-109. 10 Goyette A, Pichette J, Tremblay M-A, Laurence A, Jermyn M, Mok K. et al. Sub-diffuse interstitial optical tomography to improve the safety of brain needle biopsies: a proof-of-concept study.. Opt Lett 2015; 40 (Suppl. 02) 170-3. 11 Kang TW, Lee MW, Choi SH, Rhim H, Lim S, Song KD. et al. A novel electrode with electromagnetic tip tracking in ultrasonography-guided radiofrequency ablation: A phantom, ex vivo, and in vivo experimental study.. Invest Radiol 2015; 50 (Suppl. 02) 81-7. 12 Huang H, Yang L-M, Bai S, Liu J. Smart surgical tool.. J Biomed Opt 2015; 20 (Suppl. 02) 28001. 13 Karargyris A, Koulaouzidis A. OdoCapsule: next-generation wireless capsule endoscopy with accurate lesion localization and video stabilization capabilities.. IEEE Trans Biomed Eng 2015; 62 (Suppl. 01) 352-60. 14 Oh S, Ahn J-H, Lee S, Ko H, Seo JM, Goo Y-S. et al. Light-Controlled Biphasic Current Stimulator IC Using CMOS Image Sensors for High-Resolution Retinal Prosthesis and In Vitro Experimental Results With rd1 Mouse.. IEEE Trans Biomed Eng 2015; 62 (Suppl. 01) 70-9. 15 Mainsah BO, Collins LM, Colwell KA, Sellers EW, Ryan DB, Caves K. et al. Increasing BCI communication rates with dynamic stopping towards more practical use: an ALS study.. J Neural Eng 2015; 12 (Suppl. 01) 016013.