Subscribe to RSS
Please copy the URL and add it into your RSS Feed Reader.
https://www.thieme-connect.de/rss/thieme/en/10.1055-s-00035023.xml
Vet Comp Orthop Traumatol 2010; 23(04): 250-253
DOI: 10.3415/VCOT-09-10-0108
DOI: 10.3415/VCOT-09-10-0108
Brief Communication
Fixin internal fixator: Concept and technique
Further Information
Publication History
Received:15 October 2009
Accepted:11 February 2010
Publication Date:
17 December 2017 (online)
Summary
This report describes the Fixin internal fixator system[a], a fracture fixation device characterised by a locking conical coupling between screw heads and titanium alloy inserts that are screwed into a stainless steel plate construct. The mechanical principles, implants, instruments and surgical technique are discussed.
Keywords
Internal fixator - osteosynthesis - locking plates - angle-stable plates - conical couplinga Traumavet S.r.l, Rivoli, Italy
-
References
- 1 Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 2002; 84: 1093-1110.
- 2 Valentini R, Martinelli B, Cosmi F. et al. Mechanical behavior of one internal fixator (O’Nil plate and screws system): a finite element study and clinical experiences. Technique in Orthopaedics 2007; 22: 173-180.
- 3 Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury 2003; 34 (Suppl. 02) suppl B63-B76.
- 4 Bae JH, Oh JK, Oh CW. Technical difficulties of removal of locking screw after locking compression plating. Arch Orthop Trauma Surg 2009; 129: 91-95.
- 5 Hol PJ, Molster A, Gjerdet NR. Should the galvanic combination of titanium and stainless steel surgical implants be avoided?. Injury 2008; 39: 161-169.
- 6 Hudson CC, Pozzi A, Lewis DD. Minimally invasive plate osteosynthesis: applications and techniques in dogs and cats. Vet Comp Orthop Traumatol 2009; 22: 175-182.