Keywords
Computed tomography angiography - computed tomography chest - computed tomography
contrast - dual energy computed tomography - low-dose computed tomography - protocol
- pulmonary embolism
Introduction
Computed Tomography (CT) forms the workhorse of imaging evaluation of thoracic diseases.
With the ever-expanding clinical spectrum of thoracic disorders, and diseases with
thoracic manifestations, there has been increasing frequency of chest CT being ordered.
Hence, there is a growing need for the radiologist, and the referring clinician to
have a basic understanding of the recommended CT examination for specific individual
indications.
The attendant concern of increased radiation exposure, especially in young individuals,
as well as the use of iodinated intravenous contrast material in contrast-enhanced
CT should be kept in mind while ordering such investigations, more so, in patients
who require repeated imaging. Hence, a balance between attaining adequate diagnostic
information and patient safety needs to be kept in perspective. In another clinical
scenario, where patients may move across institutions or hospitals for treatment,
with the availability of standardised imaging protocols, there should be no need for
repeat imaging as recurrent imaging would entail additional radiation burden and contrast
administration.
Although ultrasound and magnetic resonance imaging (MRI) are also being increasingly
used in the evaluation of the chest, this review however, confines itself to CT. This
review article aims to summarize the recommended thoracic CT protocols for various
clinical/radiological indications including their technical parameters as well as
applications of newer advancements in day-to-day clinical scenario based on current
literature. The review does not address the status of ECG-gated cardiac/aortic CT.
This manuscript was prepared as a part of initiative of Indian College of Radiology and Imaging (ICRI) to standardise imaging protocols in chest imaging.
Protocols Vs Clinico-Radiographic Indications
Protocols Vs Clinico-Radiographic Indications
The indication to perform a chest CT can be clinical, or based on an abnormality on
prior imaging studies such as chest radiograph (CXR), fluoroscopy, MRI or abdomen
CT. In almost all clinical scenarios, chest radiograph should be performed initially.
Findings on CXR would help to tailor the appropriate CT examination. However, in several
instances, CT will be performed even if the chest radiograph is normal e.g. Pyrexia
of unknown origin (PUO). Hence, the use of the term clinico-radiographic indications
is apt.
Broadly, the protocols may be divided into non-contrast CT (NCCT), contrast-enhanced
CT (CECT) and then multiple modifications are available within this basic framework
[[Table 1]]. [[Table 2]] details the choice of CT protocol based on the clinico-radiographic indications.
There are certain aspects of CT acquisition, though, which are common amongst all
the protocols. Currently, all thoracic CT scans should be acquired in volumetric mode
in full inspiration. Sequential mode may be used while acquiring limited expiratory
scans. Certain clinical situations mandate the use of intravenous (IV) contrast such
as evaluation of pyrexia of unknown origin (PUO) or acute infections. Omission of
contrast in such scenarios can lead to inadequate evaluation of critical findings
like mediastinal lymph nodes or complications.
Table 1
Types of Imaging protocols
|
CT protocols
|
|
|
NCCT - Non-contrast CT; LDCT - low dose CT; CECT - Contrast enhanced CT; CTPA -CT
pulmonary angiography; CTA - CT angiography
|
|
Non-contrast CT chest protocols
|
Routine NCCT
LDCT
Ultra -LDCT
Cine CT
|
|
Contrast-enhanced CT chest protocols
|
Routine CECT
|
|
CT angiography protocols
|
CTPA
CTA
Combined protocols
Split-bolus protocol
Triple rule out
|
|
For masses/nodules (Functional Imaging)
|
Dynamic multiphasic CT
Perfusion CT
|
Table 2
Choice of Chest CT protocol according to clinico-radiographic scenario
|
Clinicoradiographic indications
|
CT Protocol
|
|
NCCT- refers to routine non contrast CT as detailed in the text; ILD- interstitial
lung disease ;CECT - Contrast enhanced CT; CTPA- CT pulmonary angiography; CTA - CT
angiography; *. Is used when these are to be used in special situations detailed in
text
|
|
Screening for pulmonary metastasis
|
NCCT
|
|
As part of Lung Cancer Screening Program
|
LDCT
|
|
Unexplained dyspnoea on exertion, suspected or known case of ILD (e.g. In connective
tissue diseases, rheumatological disorders), follow -up of ILD
|
NCCT
|
|
Suspected or known bronchiectasis, small airway disease
|
NCCT/LDCT
|
|
PUO
|
CECT (chest and abdomen)
|
|
Non-resolving pneumonia
|
CECT
|
|
Mediastinal widening
|
CECT
|
|
Malignant pleural effusion, empyema, chest wall disease
|
CECT
|
|
Staging and follow-up of lung cancer
|
CECT, Biphasic protocols*
|
|
Staging and follow -up of lymphoma
|
CECT (neck, chest and abdomen)
|
|
Unexplained vocal cord palsy
|
CECT
|
|
Evaluation of solitary pulmonary nodules
|
CECT, Dynamic multiphase CT
|
|
Blunt or penetrating chest trauma
|
CECT, CTA
|
|
Recurrent/Significant haemoptysis
|
CTA, Split-bolus CTA
|
|
Atypical chest pain (additional diagnosis other than acute coronary syndrome is considered
e.g., Pulmonary embolism or aortic dissection)
|
CTA
|
|
Intermediate to high clinical probability of pulmonary thromboembolism or positive
D-dimer level including pregnant patients (ACR Appropriateness Criteria, revised 2016)
|
CTPA
|
Non-Contrast Ct (Ncct) Chest Protocols
Non-Contrast Ct (Ncct) Chest Protocols
NCCT chest can be performed in various protocols such as routine NCCT in standard
dose, low dose CT (LDCT) or Ultra-LDCT and their indications and technical parameters
are summarized in [[Table 3]].
Table 3
NCCT chest protocols according to indications
|
Routine NCCT/standard dose CT
|
Low-dose CT
|
Ultra Low-Dose CT
|
|
*Use of LDCT in ILD is recent concept, explained in text.; ABPA- Allergic bronchopulmonary
aspergillosis; CF- Cystic fibrosis; ILD - interstitial lung diseases; NS- Non specified.
#With modern scanners and availability of iterative reconstructions, a radiation dose
of 2-3mSv is possible
|
|
Indications
|
Suspected pulmonary metastases ILD
Bronchiectasis
Deranged renal parameters
|
ILD evaluation*
Lung cancer screening
Follow-up imaging for nodules/pulmonary infections, bronchiectasis, ABPA, CF
|
Lung cancer screening/nodule detection Screening lung as a part of coronary CTs.
|
|
Acquisition protocol
|
|
|
|
|
kVp
|
100 (<~80kg)
120 (~80-113kg)
140 (>113kg)
|
80-120
|
120-140
|
|
mA with AEC
|
35
|
22
|
Without AEC
|
|
Tube current (mAs)
|
130-200
|
20-40
|
Employs a fixed mAs value- 10
|
|
Collimation
|
Lowest possible on the scanner (e.g. 0.6)
|
Lowest possible on the scanner
|
Lowest possible on the scanner
|
|
Pitch
|
1.2
|
Highest pitch
|
NS
|
|
Rotation time
|
0.5
|
0.5
|
NS
|
|
Slice thickness
|
1.2-1.5mm
|
1.2-1.5mm
|
NS
|
|
Matrix
|
512×512
|
512×512
|
512 × 512
|
|
Expected Radiation Dose
|
3-8 mSv#
|
1-3 mSv
|
0.182±0.028mSv
i.e. <1 mSv
|
Routine NCCT
Frequent indications of NCCT chest are suspected cases or follow up of metastasis,
bronchiectasis, ILD and pulmonary infections.
Image acquisition
All non-contrast scans should be acquired in volumetric mode, scanning extending from
thoracic inlet to caudally include upper abdomen [[Figure 1]]. Patients are imaged in supine position in suspended deep inspiration with arms
extended overhead to reduce beam hardening artefact. Some modifications of the NCCT
scans include expiratory and prone scans.
Figure 1 (A-D): NCCT Chest (Routine): (A) Supine topogram image: the red box shows the area of coverage
for routine chest CT, extending from thoracic inlet to upper abdomen. Images reconstructed
in soft kernel in standard lung b50s (B) and mediastinal windows b30s (C); and in
high-resolution reconstruction algorithm b80s (D)
Image reconstructions
The acquired CT images are reconstructed into soft tissue mediastinal window (20-30
kernel) and lung window (in sharp algorithm, 60-80 kernel) and in 1.2 -1.5 mm section
thickness for interpretations. The 60-80 kernel reconstruction becomes the high resolution CT and hence HRCT chest need not be acquired in sequence mode separately as in earlier
times. Thus, non-volumetric sequential mode HRCT has no indication in current era
and any volumetric CT chest data can be reconstructed in high-resolution algorithm.
The classic HRCT chest protocol was used in earlier times for acquiring high resolution images of
lung parenchyma. The technique includes using thin collimation, usually 1-2 mm, which
improves the spatial resolution and coupled with a high spatial frequency reconstruction
algorithm which makes the structure visibly sharper. The images are acquired at 10mm
interval, thereby considerably reducing the radiation dose. In the centres where MDCT
is not available, HRCT acquisition is still used for evaluation of diffuse lung diseases.
The volumetric data can be further subjected to various post-processing on workstations
such as multiplanar reconstructions (MPRs), maximum intensity projection (MIP), minimum
intensity projection (minIP), volume rendered images for virtual bronchography, and
virtual bronchoscopy to evaluate airways [[Figure 2]]. Amongst these, minIP should be performed whenever airways are to be evaluated,
and MIP images for nodule identification.
Figure 2 (A-D): Image reformatting: (A and B) Sagittal and coronal reformation in standard lung window
to allow three-dimensional view. (C) Axial maximum intensity projection (MIP) in lung
window for enhanced visualization of nodules. (D) Coronal minimum intensity projection
(minIP) in lung window for assessment of tracheobronchial airway. (D) Virtual bronchography
(volume rendered display) for visualization of airways
Expiratory scan
These scans are mainly acquired in cases of suspected air-trapping, small airway disease or tracheobronchomalacia,
and may include contiguous acquisition similar to the supine inspiratory scan, or
a sequential three-step acquisition involving upper thoracic trachea, carina and lung
bases through the diaphragm [[Figure 3]]. Scans can be acquired as sequential step-wise acquisition which delivers less
radiation and is preferred in young patients, while volumetric mode can be used in
elderly patients. Whenever there is appearance of ground glass opacities, mosaic pattern
on routine NCCT or suspicion of an airway dominant disease, it is necessary to acquire
an expiratory CT. In fact a further modification of this is the cine CT described
subsequently in detail.
Figure 3 (A and B): NCCT variants. (A) Inspiratory scan showing mild mosaic attenuation (arrow). (B)
Expiratory CT performed in low dose shows multiple areas of air trapping (black arrows).
Note the bowing of posterior walls of bronchi suggesting adequate expiratory phase
(white arrow)
Prone scans
Prone position is advised to differentiate between dependent density and features
of early interstitial lung disease, when there is equivocal increase in attenuation
and reticulation noted on dependent parts of bilateral lung parenchyma on routine
supine scan [[Figure 4]]. The acquisition should be restricted to the area of interest.
Figure 4 (A and B): NCCT variants. NCCT chest in supine (A) position shows ground glass opacities in
posterior basal segments of bilateral lower lobes (arrows). CT performed in prone
position (B) shows clearing of the GGOs suggestive of dependent densities (arrows)
Low-dose CT (LDCT)
LDCT protocols have been developed for patients requiring repeated imaging such as
several patients with interstitial lung disease (ILD) or nodule. Hence, the need to
adhere to ALARA (As Low As Reasonably Achievable) principle cannot be over emphasized.
Guidelines exist for dose optimization depending on indications.
For nodule detection/Lung cancer screening
Low-dose protocol is recommended for pulmonary nodule follow-up as well as screening
for lung cancer in select high-risk patients.[[1]] Low-dose CT refers to scanning techniques which use tube current less than 100
mAs in an attempt to deliver reduced radiation dose to the patient while maintaining
diagnostic quality images.[[2]] However, several technical parameters relating to the scan acquisition needs to
be modified to achieve optimal results. Usually, low dose CT is performed using tube
voltage of 120 kVp (KVp is adjusted according to patient’s weight) and tube current
ranging from 40-80 mAs. Such low tube-current generates increased image noise, which
can be partially compensated by using iterative reconstruction algorithm (now available
with many CT manufacturers). However, the vast majority of scanners in the world are
still without iterative reconstructions software and use images reconstructed using
conventional filtered back-projection [[Figure 5]].
Figure 5 (A-C): Low dose CT (LDCT) nodule follow-up. (A).LDCT done in a 46-year old chronic smoker
shows a nodule in left lower lobe (white arrow).(B) Follow-up LDCT done 6 months later
shows no interval change in size. (C) Axial maximum intensity projection (MIP) image
in lung window shows another smaller nodule (black arrow) in right lower lobe in addition
to left lower lobe nodule
Reconstructed slice thickness is kept at 2.5 mm or higher (for non-targeted FOV in
low frequency algorithm) while a slice thickness of 1.0-1.5 mm at high frequency algorithmic
reconstruction needs to be done through the region of interest (ROI) to improve spatial
resolution. The ROI needs to be viewed in both low- and high-spatial-frequency algorithm
as the latter reconstruction may erroneously show high density edge artifacts simulating
calcium. Recent evidence shows that there is no significant difference in inter-observer
and intra-observer variability in measurement of nodule volumes when low-dose CT is
compared to standard dose CT, suggesting that the former can be used for follow up
of pulmonary nodules.[[2],[3],[4],[5]] Various studies have been performed with different combinations of kVp and mAs
in the context of low-dose CT leading to variable estimated doses, but on an average
an acceptable low-dose CT screening can be performed with an approximate effective
dose of 2mSv.[[6]]
For suspected ILD
Use of low dose CT is a recent concept in imaging of ILD. An attempt should be made
henceforth to modify unstructured protocols and achieve dose <3 mSv even in ILD patients.
The current recommendations for performing CT for imaging evaluation of suspected
ILD includes volumetric acquisition with sub-millimetric collimation, highest pitch
and shortest rotation time. Tube voltage and tube current are determined based on
patient size. The recommended acquisitions include supine sustained end-inspiratory
phase (volumetric) and supine sustained end-expiratory (volumetric or sequential)
phase [[Figure 6]]. Additional optional scan includes prone inspiratory scan (volumetric or sequential)
limited to lower lobes. Image reconstruction is done at thin slices (1.5 mm) at high-spatial-frequency
algorithm which can be contiguous or overlapping. Post-processing tools including
minIP and MIP to be used to assess low attenuation lesions and micronodular infiltration,
respectively. The radiation dose for first acquisition (i.e. volumetric inspiratory)
should be between 1 to 3 mSv (low-dose CT), with added caution to avoid ultra-low
dose CT (<1 mSv).[[7]]
Figure 6 (A-D):LDCT for evaluation of ILD. (A) Axial image of LDCT in high resolution reconstruction
algorithm in a 65-year old chronic smoker with suspected ILD. (B and C) Routine axial
and coronal reconstruction in lung window allow evaluation of cranio-caudal and axial
distribution of reticulations, interlobular septal thickening and macrocysts. (D)
Curved MPR along the axis of bronchus (black arrow) allows distinction between honeycombing
or macrocysts and traction bronchiolectasis
Ultra-low dose CT
When doses are kept at <1 mSv, it is often referred to as ultra-low dose CT. Its utility
has been shown in screening for lung cancer and in screening for lung nodules as a
part of coronary CT.[[8]] This is strictly restricted to screening/surveillance and not for routine clinical
evaluation of lung parenchyma.
Cine CT
Cine CT is not available in every scanner, and if available tailor coverage to airway
(critical areas being lower trachea and carina). Cine CT without table feed during
free breathing has been investigated as an alternative diagnostic modality for assessment
of dynamic airway collapsibility and has been found to have comparable diagnostic
efficacy as flexible bronchoscopy, which is considered the gold standard for diagnosis[[9],[10],[11]] [[Figure 7]]. In fact, the former is considered better than paired static inspiratory/expiratory
images. Initial studies had used electron beam CT and single detector CT for cine
acquisition of airway during functional manoeuvres and showed encouraging results,
albeit with limited z-axis coverage and increased radiation dose.[[12]] Subsequently, 64-slice MDCT with z-axis coverage of more than 3 cm was successfully
employed for dynamic airway assessment during coughing.[[13]] The anatomical coverage was further extended to 16 cm using a 320-row MDCT by Wagnetz
U et al. to cover the airway from lower end of larynx to the origin of lower lobe bronchi.[[14]]
Figure 7 (A and B): Cine CT showing dynamic collapsibility of right main bronchus more than 50 percent
suggestive of bronchomalacia. (A) Saved screenshot of inspiratory phase. (B) Saved
screenshot of expiratory phase. (C)Video file (supplementary).
[MULTIMEDIA:1]
Recently, respiratory gated 4D CT of the whole chest has been performed with a dose-modulated
protocol at a pitch of 0.09 (lowest possible), minimal exposure parameters (80 kVp
and 10 reference mAs) and thin collimation (16 × 1.2 mm). Image reconstruction was
done using iterative reconstruction algorithm, at slice thickness of 1.5mm at increments
of 1.0 mm in a medium soft kernel.[[15]] The reported radiation dose ranged from 2.9 to 3.1 mGy CTDIvol. The radiology technicians should be aware of such advanced protocols available in
the scanners.
Contrast Enhanced Ct (Cect) Chest Protocols
Contrast Enhanced Ct (Cect) Chest Protocols
The numerous options of contrast enhanced scans range from a routine contrast enhanced
CT (CECT) to CT perfusion scans. Various contrast media are available for use in contrast
enhanced CTs. For routine CECT, iodine concentration of 300-350 mgI/ml suffices whereas
for CT angiography protocols, a higher concentration of 350-400 mgI/ml is preferred.
The dose of contrast to be administered depends on the weight of the patient and current
CT scanners allow 1-1.5 ml/kg to be used for routine CECT as well as CTA protocols.
Doses up to 2 ml/kg may sometimes be employed for CTA protocols in obese patients.
Availability of Dual energy CT scanners further helps to reduce the contrast dose
because of better contrast visualization at lower keV images.
Routine CECT chest
Routine CECT chest essentially retains the same parameters as NCCT with administration
of intravenous contrast. Usually a scan delay of 55-70 seconds is kept following administration
of contrast to allow for optimal enhancement of soft tissues[[16]] [[Figure 8]]. Contrast is usually delivered using hand injection with optional use of power
injector and bolus chase. CECT chest is often coupled with upper abdomen (liver and
adrenals) for baseline staging and follow-up of lung cancer, and with abdomen and
neck for PUO evaluation or other malignancies such as lymphoma staging. Two different
protocols exist for the same: the first one involves single delayed acquisition of
chest and abdomen. The other one uses dual acquisition-an earlier acquisition for
chest (20-35 seconds delay), and a second delayed acquisition for abdomen in portal
venous phase. Although, no consensus exists over the superiority of one protocol over
another, recent evidence suggests that a single 60 seconds delayed scan covering chest
and abdomen offers better image quality in terms of improved lymph nodal visualisation,
reduced perivenous contrast- related artefacts, lower radiation dose with acceptable
thoracic vascular and hepatic parenchymal enhancement.[[17]] Some authors also suggest a modified contrast infusion protocol for better visualisation
and characterisation of a pleural disease with a greater infusion rate (150 ml at
2.5 ml/sec).[[18]]
Figure 8 (A-C): (A-C) Contrast-enhanced CT chest (Routine). Axial, coronal and sagittal reformations
in standard mediastinal window. The cross-bar allows three-dimensional localization
of lesion
The various modifications of contrast-enhanced scans as discussed below and detailed
in [[Table 4]] are related to the volume, rate and manner of contrast injection (monophasic vs
biphasic), timing of scan acquisition and use of dual energy.
Table 4
Protocols of contrast enhanced scans for opacification of pulmonary and systemic circulation
|
CTPA (Pulmonary circulation)
|
CTA (Systemic Circulation)
|
Combined protocol- (Pulmonary + systemic circulation)
|
|
60 HU is used by several dual source DECT scanners. Pulmonary embolism can be missed
when images with very bright contrast is viewed only on mediastinal window settings
|
|
Indication
|
Pulmonary embolism
|
Aorta and its branches
|
Both pulmonary artery and aorta and its branches.
|
|
Area of coverage
|
Lung apex to level of diaphragm in all cases. Just above aortic arch to just below
heart (in young or pregnant patients with normal CXR and minimal suspicion of PE)
|
Thoracic inlet to lower border of L2
|
Thoracic inlet to lower border of L2
|
|
Slice thickness For reconstruction
|
≤2mm
|
≤1.5mm
|
≤1.5mm
|
|
kVp
|
For patients <30 years and 30-60 years: 120, 100 or 80 kVp depending on patient BMI
or automatic tube voltage selection For patients >60 years: 120 kVp
|
100kVp
|
Dual energy (80kVp and 140kVp
|
|
mAs
|
For patients <30 years: 150 mA with tube current modulation.
For patients 30-60 years and >60 years: 200 mA with tube current modulation.
|
Automated tube current modulation
|
Automated tube current modulation
|
|
Rate of contrast injection (where applicable)
|
3-4ml/s (normal resting heart rate)
4-5ml/s (elevated cardiac output)
|
3.5-4ml/sec
|
3/4th contrast at 5ml/s
1/4th contrast at 3ml/s
Saline chase at 3ml/s
|
|
ROI position (where applicable)
|
Pulmonary trunk or MPA or right atrium
|
Descending aorta
|
Ascending aorta
|
|
Threshold HU (where applicable)
|
60-100HU*
|
100HU
|
100HU
|
|
Time delay/phase of acquisition
|
4-5 sec after bolus trigger time
|
6 sec after bolus trigger time
|
5 sec after bolus trigger time
|
|
Reconstruction
|
Contiguous image reconstruction at intermediate-spatial-resolution algorithm. View
in cine mode at window width 450-600HU and window level 35-100HU (#) and maximum intensity
projections (MIP)
|
Reconstruction interval 2.0mm or similar depending upon scanner, at standard mediastinal
window (Window level 40HU, window width 400HU)
|
Axial image reconstruction at 1.5 mm slice thickness and increment of 1.2 mm at standard
mediastinal and lung windows.
|
Protocols for primary visualisation of vascular tree (CT angiography protocols)
Different CT angiography protocols are devised to account for different time of peak
opacification of the two vascular trees of chest, pulmonary and systemic (aortic)
following IV contrast, with the former opacifiying 10-14 seconds earlier.
CT Pulmonary angiography (CTPA)
CTPA is performed for suspected pulmonary embolism (PE), follow up of PE and evaluation
of cause of pulmonary artery hypertension. CTPA should be performed during shallow
inspiratory breath hold; mainly to avoid Valsalva manoeuvre associated with deep inspiration during the acquisition
as it can lead to poor vascular opacification due to dilution of contrast bolus with
unopacified blood flowing from inferior vena cava.[[19]] For very sick patients, or those who cannot follow respiratory commands, CTPA can
also be performed with free-breathing by increasing the pitch in dual-source CT scanners
(up to 3) so that the scan is complete in less than a second.[[20]] The same when coupled with low-voltage and iterative reconstruction algorithm can
substantially reduce the radiation dose with acceptable image quality.[[19]]
CTPA scans should be acquired in caudo-cranial direction to avoid streak artefacts from dense contrast media in superior vena cava or subclavian
vein, thus allowing time for the saline chaser to clear off the contrast to chest
by the time imaging proceeds to that level [[Figure 9]]. To avoid these artefacts, some authors have also proposed a triphasic contrast
injection protocol that allows for graded decrease in contrast concentration in a
phasic manner i.e., Phase 1: 50 ml of undiluted contrast agent, phase 2: 30 ml of
contrast in 70%:30% dilution of saline and contrast, and phase 3: 50 ml of pure saline).[[20]] A minimum mean attenuation value of 250 HU is required in main pulmonary artery
for accurate diagnosis of pulmonary embolism.[[21]]
Figure 9 (A-D): CT Pulmonary angiography (CTPA on a DECT scanner). (A) ROI positioning in right atrium.
(B) Enhancement curve for bolus tracking showing the beginning of acquisition at 60HU.
Axial (C) and coronal (D) MIP images show the optimal visualisation of main pulmonary
artery and peripheral branches
With the advent of dual-energy CT, there have been several advancements in the technical aspect of image acquisition
and post-processing of CTPA. The most important advantages of image acquisition in
dual energy mode are: (1) generation of material density display which can be used
to generate iodine perfusion maps providing panoramic visual assessment of lung parenchyma
thereby, highlighting any focal areas of perfusion defect, (2) generation of virtual
non-contrast images, and (3) post-processing for image optimization (like low keV
images can be used even if the contrast opacification was not adequate due to an error
in timing or calculating the dose of contrast bolus).[[19]] Several studies have shown that a combination of high pitch (using dual source
scanner), low tube-voltage acquisition with iterative reconstruction for post-processing
can not only significantly reduce patient dose with comparable image quality, but
can also achieve improved temporal resolution (reducing motion artefacts and allowing
simultaneous cardiovascular evaluation) with reduced contrast dose.[[19]]
In cases of chronic pulmonary thromboembolism (PTE), the CT can be done in two phases (pulmonary and systemic) when using dual energy CT. This helps to generate iodine
perfusion maps, to demonstrate the areas of perfusion defects in pulmonary arterial
phase, which subsequently gets opacified in late (aortic) phase if sufficient collateralisation
has taken place[[22]] [[Figure 10]]. Even when using single source MDCT scanners, biphasic protocol is advocated for
demonstration of systemic collaterals that develop in chronic PTE.
Figure 10 (A-D): Iodine map (DECT-CTPA) in an 83-year old female with chronic pulmonary thromboembolism.
(A and C) Axial and coronal color-coded iodine map overlay generated from pulmonary
arterial phase shows multiple wedge-shaped perfusion defects peripherally in bilateral
hemithorax. (B and D) Axial and coronal colour –coded iodine map overlay of subsequently
acquired aortic phase; shows uniform distribution of iodine bilaterally suggestive
of homogenous arterial perfusion (through systemic collaterals), filling previous
areas of pulmonary perfusion defects
CT Angiography for systemic arteries
The term CT angiography (CTA) is used when primarily the focus is on systemic circulation
(aorta and its branches)[[Figure 11]]. CTA of thorax is essentially performed in three scenarios 1. Evaluation of hemoptysis
which includes pre-procedural imaging for bronchial artery embolization, 2. Suspected
aortic dissection/aneurysm, 3. Demonstration of anomalous artery in congenital lung
malformations (e.g., sequestration). Among these, CTA for aortic dissection/aneurysm
evaluation requires an ECG gated acquisition, the complete discussion of which is
beyond the scope of this article.
Figure 11 (A-D): CT thoracic angiography - CTA. (A) ROI positioning in descending thoracic aorta with
trigger at 100 HU. Axial (B and C) and Coronal (D) reconstructed images show faint
attenuation of right sided heart and pulmonary arteries, with predominant opacification
of left sided heart and aorta
CT angiography for haemoptysis
MDCT angiography of thorax is increasingly being recommended in the diagnostic work-up
and management of hemoptysis, especially for planning of bronchial artery embolization (BAE).[[23]] Antoine Khalil et al.[[24]] described an angiographic protocol on 16-slice scanner (120kV and 180 mA) which
involved cranio-caudal scan acquisition from lung apices to lung bases in supine position
and maximum inspiratory breath hold. However, a more extensive coverage from the base
of the neck till the level of renal arteries is recommended, corresponding to L2 vertebral
level to include non-bronchial systemic supply from branches of arch of aorta and
infra-diaphragmatic arteries.[[25]] The protocol is described in [[Table 4]].
Combined protocols (For pulmonary and systemic circulation)
There is a growing trend towards achieving adequate opacification of both aortic and
pulmonary systems in a single acquisition to allow simultaneous evaluation without
additional exposure of multiple scans. This is primarily achieved by using split-bolus
techniques for contrast administration or prolonged administration of contrast.
Split-bolus protocol for hemoptysis
A comprehensive evaluation into the source of hemoptysis requires optimal enhancement of both bronchial (systemic) and pulmonary arterial
bed in a single examination.[[26]] Hence, CT using biphasic contrast bolus injection is advocated for optimal visualization
of both pulmonary arteries and thoracic aorta without additional radiation or contrast
compared to monophasic contrast injection.[[27]] Although the earlier protocols used higher doses of undiluted contrast, the contrast
dose has significantly come down with the current generation of scanners, especially
with the introduction of dual energy CT. The authors have adopted a similar biphasic
contrast-injection protocol (split-bolus) with added modifications, which is currently
being followed at our institute for evaluation of haemoptysis and is described in
[[Table 4]]. The scan thus acquired allows evaluation of bronchial arteries (branches of thoracic
aorta), non-bronchial systemic supply as well as the pulmonary vessels, in a single
acquisition with smaller contrast dose.[[28]] The benefit of opacification of pulmonary vessels is that in addition to detecting
the pulmonary arterial causes of haemoptysis (like pseudoaneurysms), the dilated pulmonary
arterial or venous branches (corresponding to areas of shunting) can also be well
seen, aiding in exact localization of bleeding [[Figure 12]].
Figure 12 (A-D): Single phase split-bolus DECT angiography in a case of hemoptysis. (A and B) ROI
positioning in ascending aorta with trigger at 100HU. (C and D) Simultaneous optimal
opacification of aorta, pulmonary artery and their branches is seen
Triple rule out CT (TRO CT)
TRO CT is a dedicated ECG gated examination aimed to evaluate aorta, coronary artery
and pulmonary artery and mid-to lower thorax in a single scan. TRO is essentially
used to rule out acute coronary syndrome (ACS), pulmonary embolism or acute aortic
syndrome as the underlying cause for patients presenting with chest pain to emergency
department (low-to moderate risk of ACS or non-ACS diagnosis considered).[[29]] The scanning length approximates 20 cm extending from above aortic arch till the
caudal aspect of heart, and is acquired in less than 15 second under ECG gating. Scan
parameters include tube voltage of 120kVp, mean effective tube current 600mAs per
se ction with mean effective radiation dose in helical mode of scanning of 18mSv without
tube current modulation and 8.75 mSv with modulation. There is extensive literature
available on ECG gated triple rule-out CT, the details of which are beyond the scope
of this article.
Protocols for multiphasic evaluation of masses/nodules (functional imaging)
Different tumours opacify at different timings following IV contrast injection based
on the tumour histology and amount of angiogenesis. A single phase CT may hence fail
to demonstrate the tumour and its extensions reliably. Also, nodules demonstrate different
peak enhancement at different times depending on aetiology. Similarly, a biphasic acquisition in two phases maybe required if all arterial and venous anatomy needs to be analysed
preoperatively or while evaluation of suspected hypervascular tumor in chest.
There are two basic modes of performing dynamic contrast-enhanced CT (DCE-CT): the
more widely available and established technique uses multiple scan acquisitions at
pre-determined time delays with respect to the initiation of contrast injection, while
the newer ‘ first pass’ technique evaluates the initial passage of contrast media
though the intravascular space by acquiring a baseline non-contrast image followed
by a series of images after contrast administration. Analysis of the temporal changes
in the contrast enhancement of the tissues allows generation of various perfusion-related
parameters that reflect the vascular status of the tissue being studied.[[30]] The former more conventional approach to DCE-CT is routinely available on the current
scanners and has more clinical acceptability while the latter is largely considered
a research tool with limited availability.
Dynamic multiphase CT
The more conventional approach involves 5-6 images acquired through the nodule at
fixed time intervals post contrast injection. This aids in characterization of the
pulmonary nodules as benign or malignant, based on enhancement characteristics[[31]] [[Figure 13]]. A similar protocol has recently been adopted in SPUtnIK trial for characterization
of incidental indeterminate solitary pulmonary nodules (SPN).[[32]] This mode of CT acquisition can be performed even on low-end scanners and the detector
collimation varies accordingly. The suitability of the nodule for multiphase CT is
initially assessed prior to performing multiphase CT. Hence, a baseline routine NCCT/LDCT
is performed to confirm the size (atleast 8mm), visibility and soft tissue attenuation
of nodule on mediastinal window. Tube voltage is kept at 100kVp for better contrast-to-noise
ratio while the tube current is modulated according to patient size. Following injection
of contrast, serial breath hold acquisitions are performed at 60 s, 120 s, 180 s and
240 s. Slice thickness is kept at 3 mm, with 2mm reconstruction interval. Nodule analysis
is performed in mediastinal window (width: 400 HU, level: 40 HU) in axial plane. The
analysis of resultant image set involves measurement of peak mean nodule enhancement
and time-attenuation curve which can be performed on most of the routinely available
commercial software.
Figure 13 (A-C): Multiphasic CT for evaluation of nodule enhancement. Magnified image in mediastinal
window of a nodule in left lower lobe. (A) NCCT and images acquired at 30 secs (B)
and 70 secs (C) post contrast injection, show awash-in of 19 HU
Perfusion CT/Dynamic ‘ first pass’ CT
Dynamic first pass contrast–enhanced perfusion CT (DCE-CT) has been used by various
investigators for quantitative assessment of perfusion parameters for characterization
of pulmonary nodules or masses, as well as for early assessment of treatment response
in lung cancer following chemotherapy.[[33],[34],[35],[36]] The current role of DCE-CT is more as a complimentary modality to established investigations
as CT and18F FDG PET-CT for lesion characterization. The CT protocol outlined in the
present review is based on the recommendations of on-going multi-centric SPUtNik trial
which assesses the diagnostic performance, costs and health outcome of DCE-CT as an
adjunct to18F FDG PET-CT for nodule characterization. Prior to performing DCE-CT,
it is essential to evaluate the suitability of the lesion using similar parameters
as detailed in dynamic multiphasic protocol.[[32]]
The institutional protocol being followed at the authors’ centre for evaluation of
perfusion in lung carcinoma uses dual-source DECT scanner with 50 ml of contrast (320
mg I/ml at 5 ml/second followed by 20 ml saline flush). Z-axis coverage varies from
7-10 cm depending on tumour. After a scan delay of 5 seconds, dynamic acquisition
of 22 scans are performed in free breathing ( first 10 scans every 3 seconds, next
5 scans every 2 seconds and next 7 scans every 4 seconds). Tube voltage and tube current
are kept at 80 kVp and 80mAs, respectively. Image reconstruction is done at slice
thickness of 5mm, reconstruction interval of 3mm and mediastinal soft tissue kernel.
Six perfusion parameters are analysed (peak enhancement intensity, blood flow, blood
volume, permeability, mean transit time and time to peak) using two-compartment analysis
model [[Figure 14]].[[37]] The [[Table 5]] below summarises the key features of two modes of performing dynamic contrast enhanced
CT for pulmonary nodules and masses.
Figure 14 (A-E): Dynamic perfusion CT of large necrotic mass to choose appropriate site of biopsy.
(A) Axial maximum intensity projection (MIP) image in mediastinal window shows large
necrotic mass in right hemithorax, with peripheral thick irregular nodular enhancement
(white arrow) and associate collapse of lung (blue arrow).Color-coded blood flow (B),
blood volume (C) and permeability (D) maps showing increased perfusion in peripheral
nodular areas of enhancement (white arrow) with hypoperfused necrotic centre. Distally
collapsed lung shows homogeneous high perfusion (blue arrow). (E) Image showing technical
parameters of the acquisition
Table 5
Key features of acquisition protocol of two subtypes of dynamic contrast-enhanced
CT
|
Dynamic multiphase CT
|
Dynamic ‘first pass’/perfusion CT
|
|
Area of coverage
|
6 cm
|
7-10 cm depending on tumour
|
|
Slice thickness
|
3 mm
|
5 mm
|
|
kVp
|
100 kVp
|
80 kVp
|
|
mAs
|
According to patient’s weight: <60 Kg, 200 mAs
60-90 Kg, 350 mAs >90kg. 500 mAs
|
80 mAs
|
|
Rate of contrast
|
2ml/sec
|
5 ml/sec
|
|
Time delay/phase of acquisition
|
Pre-contrast, 60 sec, 120 sec, 180 sec and 240 sec.
|
Scan delay: 5 sec, 22 dynamic acquisitions: first 10 scans every 3 sec, next 5 scans
every 2 sec and next 7 scans every 4 sec
|
|
Reconstruction
|
Reconstruction interval: 2mm
Standard mediastinal window: (windowlevel: 40HU, width: 400HU)
|
Reconstruction interval: 3 mm
Standard mediastinal window: (windowlevel: 40HU, width: 400HU)
|
|
Parameter available
|
Peak enhancement (HU), Wash in and wash out percentages
|
Blood flow, blood volume, permeability, mean transit time, time to peak
|
Paediatric Application of Ct Chest Protocols
Paediatric Application of Ct Chest Protocols
While most of these protocols would be applicable to children, but typically multiphasic
CT imaging should be restricted in children, and dynamic CT perfusion is almost never
used for characterisation. Substitution with USG and MRI should be considered whenever
feasible. Additional equipment and vendor specific features of dose reduction should
be adopted, and general principles of ALARA e.g. restriction of coverage should be
adhered to even more strictly. Elaborating on the specific paediatric protocols in
terms of sedation, contrast doses, radiation concerns is beyond the scope of this
article.
Conclusion
The use of CT for evaluation of thoracic disorders has increased manifold with the
ever increasing clinical indications. Paralleling the recent developments in CT hardware
and software, the various protocols of CT acquisition are also evolving with the main
objective of reduced contrast and radiation dose, improved image quality and reduced
scan time allowing for generation of evidence-based recommended CT protocols for specific
indication. Hence, the need for radiologists and clinicians alike to be aware of the
standardized thoracic CT protocols to allow for uniformity and consensus opinion across
institutions.